Uni-T UT219M [7/20] X buttons
Содержание
- Content 1
- Limited warranty liability 1
- Preface 1
- I overview 2
- Ii unpacking inspection 2
- Iii safe operation rules 2
- Iv features 4
- V electrical symbols 4
- Vi comprehensive specifications 5
- Vii overall configuration 5
- Viii lcd display ix knobs 6
- X buttons 7
- Measuring 8
- Xi operating instruction for 8
- 页 10 10
- 页 11 11
- 页 12 12
- 页 13 13
- 页 14 14
- 页 15 15
- Xii technical specifications 16
- 页 16 16
- 页 17 17
- Frequency 18
- In case of capacitance to be measured 1 pf it is suggested that the accuracy of measurement can be guaranteed only by using the rel measurement mode 18
- Mhz 1 vrms a 30 vrms 18
- Resistance measurement 8 capacitance measurement 18
- 页 18 18
- Xiii maintenance and repair 19
- 页 19 19
- 页 20 20
Похожие устройства
- Uni-T UT219DS Инструкция по эксплуатации
- Uni-T UT219DS Документация
- Uni-T UT219DS Инструкция EN
- Uni-T UT219DS Расширенная инструкция
- Uni-T UT220 Инструкция по эксплуатации
- Uni-T UT220 Документация
- Uni-T UT220 Инструкция EN
- Uni-T UT220 Расширенная инструкция
- Uni-T UT221 Инструкция по эксплуатации
- Uni-T UT221 Документация
- Uni-T UT221 Инструкция EN
- Uni-T UT221 Расширенная инструкция
- Uni-T UT222 Инструкция по эксплуатации
- Uni-T UT222 Документация
- Uni-T UT222 Инструкция EN
- Uni-T UT222 Расширенная инструкция
- Uni-T UT223A Инструкция по эксплуатации
- Uni-T UT223A Инструкция EN
- Uni-T UT233 Инструкция по эксплуатации
- Uni-T UT233 Инструкция по эксплуатации
UT219E Operating Manual X Buttons UT219E Operating Manual 4 HOLD button Press this button once the displayed values will 1 RANGE Press RANGE button once to enter MANUAL measurement mode and change the range Press RANGE button for 2 seconds and more to change from Manual range to Auto range This is only valid for AC DC voltage AC current resistance and be locked and held LCD will display E prompt if press it again the locking is released and enters normal measurement mode This is suitable for full range 5 A OFF It turns off the auto backlight function if restart is frequency measurement required rotate the function switch to OFF position 2 MAX MIN to turn it on again Press MAX MIN button once LCD will display MAX symbol enter the MAX measurement mode and display the maximum value if press it again the LCD will display MIN symbol enter the MIN measurement mode and display the minimum value Repeat in this order Press this button for at least 2 seconds to exit the MAX MIN measurement This is only valid for AC DC voltage AC current 6 Hz In AC voltage AC current measurement mode press Hz button once to enter frequency measurement mode press Hz button again to enter Duty Ratio mode In Frequency Duty Ratio measurement mode press Hz button once to enter Duty Ratio measurement mode press Hz button again to enter frequency mode resistance temperature capacitance measurement 7 SELECT Press SELECT button once to select combined function of the position on main display 3 REL ZERO Press REL button once to enter MANUAL range mode LCD will display A symbol and take the Pressing and holding SELECT button while turning the unit on cancels Auto OFF function existing displayed values as reference then it displays the difference between the measured value and the referential values This is only valid for measurement of AC DC voltage AC current resistance and frequency 11 12