OPTIONS
Compressor thermal overload relays -
Safety electronic devices that, added to the standard protection devices, protect
compressor motors against overload and current unbalance.
Phase monitor - Device that monitors input voltage and stops the chiller in case of phase loss or wrong phase sequence.
Under / Over voltage control - Electronic device that monitors and displays input voltage, and stops the chiller in case of phase
loss, wrong phase sequence, or voltage exceeding minimum and maximum allowed values.
Energy meter -
Device installed inside the control box that displays all chiller electrical power parameters at line input such as line
voltage and phase current, input active and reactive power, active and reactive energy. An integrated RS485 mod
ule allows a
Modbus communication to an external BMS.
Capacitors for power factor correction - Devices that increase the power factor of the unit. The capacitors are “dry
self-regenerating type with over pressure disconnecting safety device insulated with a no toxic dielectric mix without PCB or PCT.
Speedtrol (fan speed control device - ON/OFF - up to -18°C) - Continuous fan speed regulation on the first fan (VFD driven) of
each circuit. It allows unit operation down to -18ºC.
Setpoint reset, Demand limit and Alarm from external device - Setpoint Reset: The leaving water temperature set-point can
be overwritten with an external 4-20mA, through the ambient temperature, or through the evaporator water temperature ΔT.
Demand Limit: Chiller capacity can be limited through an external 4-
20mA signal or via network. Alarm from external device: The
unit controller is able to receive an external alarm signal. The user can decide whether this alarm signal will stop the unit or not.
Compressors circuit breakers Safety devices that include in a single device all safety functions otherwise provided by standard
fuses and optional thermal relays, such as protection against overcurrent, overload, current unbalance.
Fans circuit breakers - Safety devices that, added to the standard protection devices, protect fan motors against overload and
overcurrent.
Fans speed regulation (+ fan silent mode) - Continuous fan speed regulation of all fans (VFD driven) for improved sound level of
the unit during l
ow ambient temperature operation. At very low temperatures, all fans except the first are switched off thus allowing
unit operation down to -18°C.
INSTALLATION
Rubber anti vibration mounts - Supplied separately, these are positioned under the base of the
unit during installation. Ideal to
reduce the vibrations when the unit is floor mounted.
Spring anti vibration mounts - Supplied separately, these are positioned under the base of the unit during installation. Ideal for
dampening vibrations for installation on roofs and metallic structures.
External tank without cabinet (500 L)
External tank without cabinet (1000 L)
External tank with cabinet (500 L)
External tank with cabinet (1000 L)
OTHER
Container Kit
Witness test
Acoustic test