MEAN WELL RPT-65F-C [95/112] Dc dc converter

MEAN WELL RPSG-160-12 [95/112] Dc dc converter
Industrial
92
Model No.
Vin
(VDC)
Vout
(VDC)
Iout
(A)
R&N
(mVp-p)
Effi.
(%)
DDR-120A-12 9~18 12 10 100 89
DDR-120B-12 16.8~33.6 12 10 100 90
DDR-120C-12 33.6~67.2 12 10 100 91
DDR-120D-12 67.2~154 12 10 100 92
DDR-120A-24 9~18 24 5 120 90
DDR-120B-24 16.8~33.6 24 5 120 91
DDR-120C-24 33.6~67.2 24 5 120 92
DDR-120D-24 67.2~154 24 5 120 93
DDR-120A-48 9~18 48 2.5 200 90
DDR-120B-48 16.8~33.2 48 2.5 200 91
DDR-120C-48 33.6~67.2 48 2.5 200 92
DDR-120D-48 67.2~154 48 2.5 200 93
Model No.
Vin
(VDC)
Vout
(VDC)
Iout
(A)
R&N
(mVp-p)
Effi.
(%)
DDR-240B-24 16.8~33.6 24 10 120 90
DDR-240C-24 33.6~67.2 24 10 120 91
DDR-240D-24 67.2~154 24 10 120 92
DDR-240B-48 16.8~33.6 48 5 200 91
DDR-240C-48 33.6~67.2 48 5 200 92
DDR-240D-48 67.2~154 48 5 200 93
DDR-240DDR-120
120W DDR-120 240W DDR-240
DC/DC Converter
120~240W DIN Rail Type
Features
General Specification (Please refer to www.meanwell.com for detail spec.)
Model No. DDR-120 DDR-240
DC input range A: 9~18V, B: 16.8~33.6V, C: 33.6~67.2V, D: 67.2~154V B: 16.8~33.6V, C: 33.6~67.2V, D: 67.2~154V
Line regulation (1 sec.) ±0.5%
Load regulation (max.) ±1%
Overload protection 110%~150% rated output power for more than 3 seconds and then shut down O/P voltage with auto-recovery
Over voltage protection 120%~135% Shut down O/P voltage, re-power on to recover
Withstand voltage I/P-O/P: 4kVDC, I/P-FG: 2.5kVDC, O/P-FG: 2.5kVDC
Isolation resistance 0ȍ#9'&
Working temperature(min.)
-40~+70°C (refer to output derating curve)
Safety
standards
Industrial Design refer to IEC62368(LVD) [except for 67.2~154Vin]
Railway Design refer to EN50155 / IEC60571, EN45545-2 (except for 9~18Vin)
EMC standards EN55032 class B, EN61000-3,-2,-3, EN61000-4-2,3,4,5,6,8; EN50121-3-2 (except for 9~18Vin)
Dimension (LxWxH)(mm)
32x 125.2x 102 63x 125.2x 113.5
ITE & Railway safety
2:1 wide input range
150% peak load capability
Protections:
Short circuit / Overload / Over voltage / Over temperature /
Input reverse polarity / Input under voltage
Cooling by free air convection
Can be installed on DIN rail TS-35/7.5 or 15
4000VDC I/O isolation (Rainforce isolation)
-40~+70
o
C wide operating temperature
DC output adjustable
DC OK relay contact (DDR-240 only)
Current sharing up to 960W (3+1) for DDR-240
3 years warranty
CB/CE pending

Содержание