Daikin EWWD550EJYNN [14/26] Features
![Daikin EWWD550EJYNN [14/26] Features](/views2/1673708/page14/bge.png)
3
1
3
• Applied Systems • Chillers
14
• Chillers • R-134A • EWWD-EJYNN
3 Features
Certifications
All the EWWD-EJ units are CE marked (89/392).
Available Series
The EWWD-EJ units are available in 3 versions:
EWWD-EJ - standard.
EWLD-EJ - special execution without water condensers. The unit is specially designed for remote air condenser
application or evaporating gas condensers; the liquid receiver must be included in the plant circuit.
EWWD-EJ/A - high efficiency units
Water content in cooling circuits
The cooled water distribution circuits should have a minimum water content to avoid excessive compressors start
and stop.
In fact, each time the compressor starts up, an excessive quantity of oil goes from the compressor’s sump and
simultaneously there is a rise in the temperature of the compressor motor’s stator due to the inrush current during
the start-up. To prevent damage to the compressors, Daikin has envisaged the application of a device to limit
frequent stops and restarts.
During the span of one hour there will be no more than 6 starts of the compressor. The plant side should therefore
ensure that the overall water content allows a more constant functioning of the unit and consequently greater
environmental comfort. The minimum installation water content envisaged should be calculated with a certain
approximation using this formula:
(1) Q = 35,83
)C(T
(kW) P
°∆
X
N
1
where:
Q = minimum content of the plant expressed in litres
P = cooling capacity of the plant expressed in W
For a more accurate determination of the quantity of water, it is advisable to contact the designer of the plant.
Содержание
- Applied systems chillers 1 1
- Chillers r 134a ewwd ejynn 1
- Features 1
- 1 technical specifications 2
- Specifications 2
- 1 technical specifications 3
- Specifications 3
- 1 technical specifications 4
- Specifications 4
- 1 technical specifications 5
- Specifications 5
- 1 technical specifications 6
- 2 electrical specifications 6
- Specifications 6
- 2 electrical specifications 7
- Specifications 7
- 2 electrical specifications 8
- Specifications 8
- 2 electrical specifications 9
- Specifications 9
- 2 electrical specifications 10
- Specifications 10
- Applied systems chillers 11 11
- Chillers r 134a ewwd ejynn 11
- Features 11
- Features 12
- Technical specifications 12
- Features 13
- General characteristics 13
- Features 14
- Features 15
- The pco2 controller 15
- Features 16
- Microplan 16
- Pco2 remote control 16
- Pco2 terminal 16
- Options 17
- Options available on request 17
- Standard options furnished on basic unit 17
- 1 cooling capacity tables 18
- Capacity tables 18
- 1 cooling capacity tables 19
- Capacity tables 19
- 1 cooling capacity tables 20
- Capacity tables 20
- 2 capacity correction factor 21
- Capacity tables 21
- 1 installation method 22
- Installation 22
- Operating limits 23
- Operation range 23
- 1 table for matching unit sizes 24
- Hydraulic performance 24
- 2 water pressure drop curve evaporator 25
- Hydraulic performance 25
- 3 water pressure drop curve condenser 26
- Hydraulic performance 26
Похожие устройства
- Daikin EWWD550EJYNN Технические данные
- Daikin EWWD650EJYNN Брошюра
- Daikin EWWD650EJYNN Технические данные
- Daikin EWWD650EJYNN Инструкция по монтажу
- Daikin EWWD650EJYNN Спецификация
- Daikin EWWD700EJYNN Инструкция по монтажу
- Daikin EWWD700EJYNN Спецификация
- Daikin EWWD700EJYNN Брошюра
- Daikin EWWD700EJYNN Технические данные
- Daikin EWWD800EJYNN Инструкция по монтажу
- Daikin EWWD800EJYNN Технические данные
- Daikin EWWD800EJYNN Спецификация
- Daikin EWWD800EJYNN Брошюра
- Daikin EWWD850EJYNN Спецификация
- Daikin EWWD850EJYNN Брошюра
- Daikin EWWD850EJYNN Инструкция по монтажу
- Daikin EWWD850EJYNN Технические данные
- Daikin EWWD900EJYNN Спецификация
- Daikin EWWD900EJYNN Брошюра
- Daikin EWWD900EJYNN Технические данные