Daikin EWWD550EJYNN [17/26] Options
![Daikin EWWD550EJYNN [17/26] Options](/views2/1673708/page17/bg11.png)
• Chillers • R-134A • EWWD-EJYNN
1
4
• Applied Systems • Chillers
17
4 Options
Standard Options (furnished on basic unit)
Heat Pump version (not for the EWLD-EJ)
Double set point
Brine double set point version (CB) - Dual leaving glycol mixture temperature setpoints. The lower setpoint can
go down to -8°C.
Compressor thermal overload relays - Safety devices against compressor motor overloading in addition to the
normal protection envisaged by the electrical windings.
Under/Over Voltage controller
Victaulic on condenser (not for the EWLD-EJ) - Hydraulic joint with gasket for an easy and quick connection.
Flow switch for evaporator
Rubber type anti-vibration mounts - positioned under the base of the unit for “floor” installation.
Set point reset, demand limit & alarm from external device
Star Delta Compressors starter – For low inrush current and reduced starting torque.
Phase monitor – The phase monitor controls the voltage values on the supply line stopping the unit when the
calibration threshold is reached (± 10%). This safety device is automatically reset.
General fault contactor – Contactor for the alarm warning.
Options (available on request)
100% total heat recovery (OPTR) – Produced with tube bundle placed in a single shell with the water
condensers. Heat exchangers heads are provided with 2 connections for entering/leaving heat recovery water and
2 separate connections for condensing water.
Partial heat recovery (OPPR) – Produced with plate to plate heat exchangers installed on discharge side of
compressor hot gas. These allow hot water to be produced up to a maximum temperature of + 50°C.
Ammeter and voltmeter (OP57) - Digital meters of unit drawn amperes and voltage values, installed on the
electrical control panel.
Condenser power factor correction (OPPF) - Installed on the electrical control panel to ensure it conforms to the
plant rules. (Daikin advices maximum 0,9).
Suction line shut off valve (OP12) – Suction shut-off valve installed on the suction port of the compressor to
facilitate maintenance operation.
Cu-Ni 90-10 exchangers (OPNI)– To work with sea water the heat exchangers are fitted with Cu-Ni tubes and
special protection inside the end covers.
Soft start (OPSS) –
Electronic starting device to reduce inrush current. An overload protection is included (no
need of compressors thermal relays).
Dual Pressure Relief Valve (OP03)
Liquid Receiver (OPLR) – available on EWLD-EJ only, the capacity is 170 Lt.
Содержание
- Applied systems chillers 1 1
- Chillers r 134a ewwd ejynn 1
- Features 1
- 1 technical specifications 2
- Specifications 2
- 1 technical specifications 3
- Specifications 3
- 1 technical specifications 4
- Specifications 4
- 1 technical specifications 5
- Specifications 5
- 1 technical specifications 6
- 2 electrical specifications 6
- Specifications 6
- 2 electrical specifications 7
- Specifications 7
- 2 electrical specifications 8
- Specifications 8
- 2 electrical specifications 9
- Specifications 9
- 2 electrical specifications 10
- Specifications 10
- Applied systems chillers 11 11
- Chillers r 134a ewwd ejynn 11
- Features 11
- Features 12
- Technical specifications 12
- Features 13
- General characteristics 13
- Features 14
- Features 15
- The pco2 controller 15
- Features 16
- Microplan 16
- Pco2 remote control 16
- Pco2 terminal 16
- Options 17
- Options available on request 17
- Standard options furnished on basic unit 17
- 1 cooling capacity tables 18
- Capacity tables 18
- 1 cooling capacity tables 19
- Capacity tables 19
- 1 cooling capacity tables 20
- Capacity tables 20
- 2 capacity correction factor 21
- Capacity tables 21
- 1 installation method 22
- Installation 22
- Operating limits 23
- Operation range 23
- 1 table for matching unit sizes 24
- Hydraulic performance 24
- 2 water pressure drop curve evaporator 25
- Hydraulic performance 25
- 3 water pressure drop curve condenser 26
- Hydraulic performance 26
Похожие устройства
- Daikin EWWD550EJYNN Технические данные
- Daikin EWWD650EJYNN Брошюра
- Daikin EWWD650EJYNN Технические данные
- Daikin EWWD650EJYNN Инструкция по монтажу
- Daikin EWWD650EJYNN Спецификация
- Daikin EWWD700EJYNN Инструкция по монтажу
- Daikin EWWD700EJYNN Спецификация
- Daikin EWWD700EJYNN Брошюра
- Daikin EWWD700EJYNN Технические данные
- Daikin EWWD800EJYNN Инструкция по монтажу
- Daikin EWWD800EJYNN Технические данные
- Daikin EWWD800EJYNN Спецификация
- Daikin EWWD800EJYNN Брошюра
- Daikin EWWD850EJYNN Спецификация
- Daikin EWWD850EJYNN Брошюра
- Daikin EWWD850EJYNN Инструкция по монтажу
- Daikin EWWD850EJYNN Технические данные
- Daikin EWWD900EJYNN Спецификация
- Daikin EWWD900EJYNN Брошюра
- Daikin EWWD900EJYNN Технические данные