SPECIFICATION
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
INRUSHCURRENT (Typ.)
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
WORKINGHUMIDITY
WORKINGTEMP.
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
ACCURRENT (Typ.)
1800ms,20ms/230VAC1800ms,20ms/115VACatfullload
100ms/230VAC24ms/115VACatfullload
85~264VAC120~370VDC
47~440Hz
74%66% 78%
13.8~16.2V
79%
17.25~20.25V
79%
27.6~32.4V
0.25A/115VAC0.15A/230VAC
COLDSTART 25A/115VAC45A/230VAC
Above105% ratedoutputpower
5.75~6.75V3.8~4.95V
Protectiontype: Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
I/P-O/P:4KVAC
I/P-O/P:100MOhms/500VDC /25 /70%RH
20~90%RHnon-condensing
-20~+70 (Refertooutputloadderatingcurve)
-40~+85 ,10~95%RH
0.03%/ (0~50
10~500Hz,2G10min./1cycle,periodfor60min. eachalongX, Y,Zaxes
723.2Khrsmin.MIL-HDBK-217F(25 )
70*50*22.7mm(L*W*H)
0.105Kg;120pcs/13.6Kg/0.97CUFT
FileName:PM-10-SPEC2010-07-19
0.5%
1.0%
0.5%
1.0%
0.5%
0.5%
1.0%
1.0%
1.0%
1.0%
150mVp-p150mVp-p 150mVp-p 150mVp-p 240mVp-p
5V3.3V 12V 15V 24V
2A2.5A 0.85A 0.67A 0.42A
0~2A0~2.5A 0~0.85A 0~0.67A 0~0.42A
10W8.25W 10.2W 10.05W 10.08W
PM-10-5 PM-10-12 PM-10-15 PM-10-24PM-10-3.3
SAFETY STANDARDS
10WOutputSwitchingPowerSupply
PM-10 series
Features :
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
EMICONDUCTION&RADIATION
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
Protectiontype: Shutoffo/pvoltage,clampingbyzenerdiode
CompliancetoEN55011 ,EN55022(CISPR22)ClassB(CISPR11)
HARMONICCURRENT
EMSIMMUNITY
Complianceto EN61000-3-2,-3
CompliancetoEN61000-4-2,3,4,5,6,8,11;ENV50204,EN55024,EN60601-1-2,EN61204-3,medicallevel,criteria A
UL60601-1, TUVEN60601-1,IEC60601-1approved
Universal AC input / Full range
Protections: Short circuit / Overload / Over voltage
Ultra-miniature size, light weight
Cooling by free air convection
Isolation class
UL60601-1/IEC60601-1/EN60601-1 medical safety approved
No load power consumption<0.5W
100% full load burn-in test
Fixed switching frequency at 67KHz
High reliability
3 years warranty
2.0%
3.0%
2.0% 2.0% 2.0%
EN60601-1
IEC60601-1