MEAN WELL TP-100B Data Sheet онлайн

MEAN WELL TP-100A Data Sheet онлайн
SPECIFICATION
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER (max.)
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE Note.5
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
OVERTEMPERATURE(OPTION)
ACCURRENT (Typ.)
800ms,60ms/230VAC 115VACatfullload800ms,60ms/
24ms/230VAC 115VACatfullload24ms/
90~264VAC127~370VDC
47~63Hz
PF>0.94/230VACPF>0.98/115VACatfullload
75% 78% 77% 78%
1.5A/115VAC0.75A/230VAC
COLDSTART 40A/230V
<3.5mA /240VAC
105~150% ratedoutputpower
CH1:5.75~6.75Von+5V
UL60950-1, TUVEN60950-1approved
-10~+60 (Refertooutputloadderatingcurve)
20~90%RHnon-condensing
-20~+85 ,10~95%RH
± 0.03%/ (0~50 )
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
170.1Khrsmin.MIL-HDBK-217F(25 )
199*99*50mm(L*W*H)
0.83Kg;20pcs/17.6Kg/1.28CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
5. Derating may be needed under low input voltages. Please check the derating curve for more details.
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
Complianceto EN55024,lightindustrylevel,criteria AEN61000-4-2,3,4,5,6,8,11;ENV50204,
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
100W TripleOutputwithPFCFunction
$
$
$
$
$
$
Universal AC input / Full range
Built-in active PFC function, PF>0.94
Protections: Short circuit / Overload / Over voltage
Free air cooling convection
Fixed switching frequency at 100KHz
3 years warranty
Features:
TP-100 se ri es
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC1min.
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
EMICONDUCTION&RADIATION
TP-100A TP-100B TP-100C TP-100D
5V 12V
CH2 CH2 CH2 CH2
-5V
CH3 CH3 CH3 CH3
12V 15V 24V-12V -15V 12V5V 5V 5V
10A 4A 0.6A 3A 2A0.6A 0.6A 0.6A10A 10A 10A
3~15A 0.4~5A 0~1A 0.4~5A 0.4~4A 0.4~3A0~1A 0~1A 0~1A3~15A 3~15A 3~15A
101W 105.2W 104W 105.2W
100mVp-p
CH1:4.75~5.5V
120mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p100mVp-p 100mVp-p 100mVp-p100mVp-p 100mVp-p 100mVp-p
± 3.0% ± 7.0% ± 6.0% ± 6.0% +10,-6% ± 8.0%± 6.0% ± 6.0% ± 6.0%± 3.0% ± 3.0% ± 3.0%
± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0%± 1.0%
± 3.0% ± 6.0% ± 4.0% ± 6.0% ± 6.0% ± 6.0%± 4.0% ± 4.0% ± 4.0%± 3.0% ± 3.0% ± 3.0%
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
FileName:TP-100-SPEC2007-10-25
INPUT
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
95 5 (TSW1)±
CH1 CH1 CH1 CH1OUTPUTNUMBER
..
4A
Скачать