MEAN WELL TP-150B Data Sheet онлайн

SPECIFICATION
MODEL
DCVOLTAGE
RATEDCURRENT
CURRENTRANGE
RATEDPOWER
OUTPUT
VOLTAGE ADJ.RANGE
LINEREGULATION
LOADREGULATION
SETUP,RISETIME
HOLDUP TIME (Typ.)
VOLTAGERANGE
FREQUENCY RANGE
POWERFACTOR (Typ.)
EFFICIENCY (Typ.)
INRUSHCURRENT (Typ.)
LEAKAGECURRENT
SAFETY STANDARDS
HARMONICCURRENT
EMSIMMUNITY
WORKINGTEMP.
WORKINGHUMIDITY
STORAGETEMP.,HUMIDITY
TEMP.COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
OVERLOAD
OVERVOLTAGE
OVERTEMPERATURE(OPTION)
ACCURRENT (Typ.)
90~264VAC127~370VDC
47~63Hz
PF>0.94/230VACPF>0.98/115VACatfullload
2.5A/115VAC1.2A/230VAC
COLDSTART 40A/230V≦
<3.5mA /240VAC
105~150% ratedoutputpower
5.75~6.75Von+5V
UL60950-1, TUVEN60950-1approved
-10~+60 (Refertooutputloadderatingcurve)℃
20~90%RHnon-condensing
-20~+85 ,10~95%RH℃
± ℃ ℃0.03%/ (0~50 )
10~500Hz,2G10min./1cycle,60min.eachalongX, Y,Zaxes
161.6Khrsmin.MIL-HDBK-217F(25 )℃
199*99*50mm(L*W*H)
0.9Kg;20pcs/19Kg/1.28CUFT
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets
EMC directives.
℃
CompliancetoEN55022(CISPR22)ClassB
Complianceto EN61000-3-2,-3
Complianceto EN55024,lightindustrylevel,criteria AEN61000-4-2,3,4,5,6,8,11;ENV50204,
RIPPLE&NOISE(max.) Note.2
VOLTAGETOLERANCE Note.3
150W TripleOutputwithPFCFunction
$
$
$
$
$
$
Universal AC input / Full range
Built-in active PFC function, PF>0.94
Protections: Short circuit / Overload / Over voltage
Forced air cooling by built-in DC fan
Fixed switching frequency at 100KHz
3 years warranty
■ Features:
TP-150 se ri es
ENVIRONMENT
SAFETY &
EMC
(Note4)
PROTECTION
WITHSTANDVOLTAGE
ISOLATIONRESISTANCE
I/P-O/P:3KVACI/P-FG:1.5KVACO/P-FG:0.5KVAC1min.
I/P-O/P,I/P-FG,O/P-FG:100MOhms/500VDC
EMICONDUCTION&RADIATION
95 5 (TSW1)℃± ℃
Protectiontype:Shutdowno/pvoltage,recoversautomaticallyaftertemperaturegoesdown
FileName:TP-150-SPEC2007-10-25
INPUT
800ms,60ms/230VAC 115VACatfullload800ms,60ms/
24ms/230VAC 115VACatfullload24ms/
TP-150A TP-150B TP-150C TP-150D
5V 12V
CH2 CH2 CH2 CH2
-5V
CH3 CH3 CH3 CH3
12V 15V 24V-12V -15V 12V5V 5V
15A 0.6A 5.5A 4.5A 3A0.6A 0.6A 0.6A15A 15A 15A
2~20A 0.4~7A 0~1A 0.4~7A 0.4~6A 0.4~4A0~1A 0~1A 0~1A2~20A 2~20A 2~20A
150W 148.2W 151.5W 154.2W
100mVp-p
CH1:4.75~5.5V
120mVp-p 100mVp-p 120mVp-p 150mVp-p 150mVp-p100mVp-p 100mVp-p 100mVp-p100mVp-p 100mVp-p 100mVp-p
± 3.0% ± 8.0% ± 6.0% ± 8.0% +10,-6% ± 8.0%± 6.0% ± 6.0% ± 6.0%± 3.0% ± 3.0% ± 3.0%
± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0% ± 1.0%± 1.0%
± 3.0% ± 6.0% ± 4.0% ± 6.0% ± 6.0% ± 6.0%± 4.0% ± 4.0% ± 4.0%± 3.0% ± 3.0% ± 3.0%
75% 77% 77% 78%
Protectiontype:Shutdowno/pvoltage,re-powerontorecover
Protectiontype:Hiccupmode,recoversautomaticallyafterfaultconditionisremoved
CH1 CH1 CH1 CH1
OUTPUTNUMBER
..
5V
6A
Содержание
Похожие устройства
- MEAN WELL TP-150C Инструкция по эксплуатации
- MEAN WELL TP-150C Инструкция язык en
- MEAN WELL TP-150C Каталог
- MEAN WELL TP-150C Data Sheet
- MEAN WELL TP-150D Инструкция по эксплуатации
- MEAN WELL TP-150D Инструкция язык en
- MEAN WELL TP-150D Каталог
- MEAN WELL TP-150D Data Sheet
- MEAN WELL TP-75A Инструкция по эксплуатации
- MEAN WELL TP-75A Инструкция язык en
- MEAN WELL TP-75A Каталог
- MEAN WELL TP-75A Data Sheet
- MEAN WELL TP-75B Инструкция по эксплуатации
- MEAN WELL TP-75B Инструкция язык en
- MEAN WELL TP-75B Каталог
- MEAN WELL TP-75B Data Sheet
- MEAN WELL TP-75C Инструкция по эксплуатации
- MEAN WELL TP-75C Инструкция язык en
- MEAN WELL TP-75C Каталог
- MEAN WELL TP-75C Data Sheet