Daikin EWAD400T-XRC2 [4/23] D eimac01502 18_02en 4 23
![Daikin EWADH10T-XSC2 [4/23] D eimac01502 18_02en 4 23](/views2/1684669/page4/bg4.png)
D–EIMAC01502–18_02EN - 4/23
Optional
Safety valves can be provided with a changeover device as optional
Legend
1
Compressor
2
Heat Recovery (optional)
3
Pressure relief valve Pset= 25,5 bar
4
Microchannel condenser coil
5
Angle valve
6
Dryer filter
7
Moisture indicator
8
Economizer heat exchanger
9
Solenoid valve
10
Termostatic expansion valve
12
Electronic expansion valve
13
Evaporator (S&T)
14
Pressure relief valve Pset= 15,5 bar
15
Access fitting ¼” SAE Flare valve
16
Ball valve
17
Copper filter
18
Receiver valve
19
Pressure gauge (optional)
20
Access fitting Tee
21
Liquid receiver (optional)
PT
Pressure trasducer
PZH
High pressure switch
TZAH
High temperature switch
PSAL
Low pressure limiter
TT
Temperature transducer
Содержание
- Air cooled chiller with screw compressor 1
- Contents 2
- D eimac01502 18_02en 2 23 2
- List of figures 2
- Original instructions 2
- D eimac01502 18_02en 3 23 3
- D eimac01502 18_02en 4 23 4
- D eimac01304 17en 5 23 5
- Introduction 5
- D eimac01502 18_02en 6 23 6
- General information 6
- Operating limits 6
- Receiving the unit 6
- D eimac01502 18_02en 7 23 7
- D eimac01502 18_02en 8 23 8
- Mechanical installation 8
- D eimac01502 18_02en 9 23 9
- D eimac01502 18_02en 10 23 10
- D eimac01502 18_02en 11 23 11
- D eimac01502 18_02en 12 23 12
- D eimac01502 18_02en 13 23 13
- D eimac01502 18_02en 14 23 14
- Sound protection when sound levels require special control great care must be exercised to isolate the unit from its base by appropriately applying anti vibration elements supplied as an option flexible joints must be installed on the water connections as well 5 water piping 14
- The water system must have 14
- D eimac01502 18_02en 15 23 15
- D eimac01502 18_02en 16 23 16
- D eimac01502 18_02en 17 23 17
- Electrical installation 17
- Maintenance 17
- Operation 17
- D eimac01502 18_02en 18 23 18
- D eimac01502 18_02en 19 23 19
- D eimac01502 18_02en 20 23 20
- Periodic obligatory checks and starting up of appliances under pressure 20
- Service and limited warranty 20
- D eimac01502 18_02en 21 23 21
- Important information regarding the refrigerant used 21
- D eimac01502 18_02en 22 23 22
- Disposal 22
- D eimac01502 18_02en 23 23 23
- Daikin applied europe s p a 23
- Via piani di santa maria 72 00072 ariccia roma italia tel 39 06 93 73 11 fax 39 06 93 74 014 http www daikinapplied eu 23
Похожие устройства
- Canton Ergo 655 CM Инструкция
- Canton Ergo 610 Инструкция
- Canton Ergo 620 Инструкция
- Canton Ergo 670 Инструкция
- Canton Ergo 690 Инструкция
- Canton AR 800 Инструкция
- Canton A 45 AR Инструкция
- Canton A 45 CS Инструкция
- Canton A 45 Sub Инструкция
- Canton A 35 Инструкция
- Canton A 45 Инструкция
- Daikin EWAD420T-XRC2 Инструкция по монтажу
- Daikin EWAD440T-XRC2 Инструкция по монтажу
- Daikin EWAD490T-XRC2 Инструкция по монтажу
- Daikin EWAD540T-XRC2 Инструкция по монтажу
- Daikin EWAD570T-XRC2 Инструкция по монтажу
- Daikin EWAD730T-XRC2 Инструкция по монтажу
- Daikin EWAD820T-XRC2 Инструкция по монтажу
- Daikin EWAD950T-XRC2 Инструкция по монтажу
- Daikin EWADC10T-XRC2 Инструкция по монтажу