Daikin FXLQ32MAVE [5/27] Vrv indoor units

Daikin FXLQ63MAVE [5/27] Vrv indoor units
FXLQ-MAVE / FXNQ-MAVE
5
Model FXLQ50MAVE FXLQ63MAVE
Power supply 1 phase, 220-240/220 V, 50/60 Hz 1 phase, 220-240/220 V, 50/60 Hz
+1 +3 Cooling capacity
kcal/h 4,800 6,100
Btu/h 19,100 24,200
kW 5.6 7.1
+2 +3 Heating capacity
kcal/h 5,400 6,900
Btu/h 21,500 27,300
kW 6.3 8.0
Power input
Cooling
50 Hz kW 0.110 0.110
60 Hz kW 0.105 0.108
Heating
50 Hz kW 0.110 0.110
60 Hz kW 0.105 0.108
Casing / Colour Ivory white (5Y7.5/1) Ivory white (5Y7.5/1)
Dimensions: (H×W×D) mm 600×1,420×222 600×1,420×222
Coil (Cross
¿n coil)
Rows × Stages ×
Fin pitch
mm 3×14×1.5 3×14×1.5
Face area
m
2
0.282 0.282
Fan
Model 2D14B20 2D14B20
Type Sirocco fan Sirocco fan
Motor output ×
Number of units
W 35×1 35×1
AirÀow rate (H/L)
m³/min 14/11 16/12
l/s 233/183 266/200
cfm 494/388 565/424
Drive Direct drive Direct drive
Temperature control
Microprocessor thermostat for
cooling and heating
Microprocessor thermostat for
cooling and heating
Sound absorbing thermal insulation material Glass ¿ber / Urethane foam Glass ¿ber / Urethane foam
Air ¿lter Resin net (with mould resistance) Resin net (with mould resistance)
Piping
connections
Liquid pipes mm
I6.4 (Flare connection) I9.5 (Flare connection)
Gas pipes mm
I12.7 (Flare connection) I15.9 (Flare connection)
Drain pipe mm
I21 O.D (Vinyl chloride) I21 O.D (Vinyl chloride)
Mass kg 36 36
+4 Sound
pressure level
(H/L)
220 V, 50/60 Hz dB(A) 39/34 40/35
240 V, 50 Hz dB(A) 41/36 42/37
Safety devices Fuse, Thermal protector for fan motor Fuse, Thermal protector for fan motor
Refrigerant control Electronic expansion valve Electronic expansion valve
Standard accessories
Operation manual, Installation manual,
Insulation for ¿tting, Drain hose, Clamps,
Screws, Washers, Level adjustment screw
Operation manual, Installation manual,
Insulation for ¿tting, Drain hose, Clamps,
Screws, Washers, Level adjustment screw
Drawing No.
Speci¿cation C: 3D038816A C: 3D038816A
Sound level C: 4D034566A C: 4D034567A
Notes:
+1. Indoor temp.: 27°CDB, 19°CWB / outdoor temp.: 35°CDB / Equivalent piping length: 7.5 m, level difference: 0 m.
+2. Indoor temp.: 20°CDB / outdoor temp.: 7°CDB, 6°CWB / Equivalent piping length: 7.5 m, level difference: 0 m.
+3. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
+4. Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m. During
actual operation, these values are normally somewhat higher as a result of ambient conditions.
Conversion formulae
kcal/h=kW×860
Btu/h=kW×3412
cfm=m³/min×35.3
l/s=m³/min×1000/60
VRV INDOOR UNITS

Содержание

Скачать