Ecosoft RObust PRO Инструкция онлайн [21/56] 542348

Ecosoft RObust PRO Инструкция онлайн [21/56] 542348
20 21
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2017
INSTALLATION AND OPERATION GUIDELINES FOR REVERSE OSMOSIS SYSTEMS
ECOSOFT ROBUST 1000, ROBUST 1500, ROBUST PRO, ROBUST 3000
Recovery has decreased
signicantly
Clogged pre-lter Replace pre-lter
Clogged membranes Replace membranes
Water is not discharged to
drain when the system is on
Clogged ow restrictor Clean ow restrictor or re-
place if necessary
Puried water is hazy or
cloudy but becomes clear
aer a few minutes
Air bubbles trapped in the
system
Some air may remain in the
system for a few days aer
installaon and will go away
on its own.
Air bubbles may appear in
water if there is a large dier-
ence between feed water and
ambient temperature
Puried water has a taste or
odor
Expired post-lter Replace post-lter
Membrane preservave was
not ushed fully aer the
installaon
Flush the RO system and
discard all rinse water
Contaminaon of the system Sanize the system according
to instrucons in p. 7
Contaminaon of pressure
tank
Sanize pressure tank.
Pressure tank may become
contaminated if lters or
membranes are used beyond
their service life
Pressure tank is not full when
the system switches o
Tank bladder is overinated Pressure in empty tank
bladder must be 0.6–1.0 atm.
Release some pressure if
necessary.
Operaon is performed by
water lter service specialist
Tank valve is closed Check tank valve posion

Содержание

Скачать