This function controls the LED brightness.
Press the “MENU” button up to visualize “ADR”. Through the “UP” and “DOWN” keys select “DIM”. Press “ENTER”
to confirm. The DMX value of the dimmer function will be thus displayed. Press the buttons “UP” or “DOWN” until
the required value appears, then press “ENTER”.
With this operation the working temperature of Leds can be checked.
Press the “MENU” button up to visualize “ADR”. Through the “UP” and “DOWN” keys select “TEM”. Press “ENTER”
to confirm.
The value of the operating temperature of LED, which should never be higher than 65°C, will appear. A higher
value indicates a malfunction of the fixture.
With this operation the working temperature of Led Drivers can be checked.
Press the “MENU” button up to visualize “DRT”. Through the “UP” and “DOWN” keys select “DRT”. Press “ENTER” to
confirm.
The value of the operating temperature of led drivers, which should never be higher than 70°C, will appear.
A higher value indicates a malfunction of the fixture.
With this operation the working temperature of Body can be checked.
Press the “MENU” button up to visualize “DRT”. Through the “UP” and “DOWN” keys select “BOT”. Press “ENTER” to
confirm.
With this operation the percentage of power that is supplied of the heater can be checked.
Press the “MENU” button up to visualize “DRT”. Through the “UP” and “DOWN” keys select “HEP”. Press “ENTER” to
confirm.
With this operation ALL the parameters can be set to the default values.
Press the “MENU” button up to visualize “ADR”. Through the “UP” and “DOWN” keys select “DEF”. Press “ENTER”
to confirm. Select “RES” or “CAN” to reset value or cancel operation.
Following parameters will be set to default values: dmx address, number of dmx channels, automatic mode, co-
lour mode.
When operating in DMX mode, the projector can accept the following RDM commands:
• discovery
Upon request of the RDM controller, the projector adverts its own presence (the RDM controller will display the
projector between a list).
• DMX address reading and setting.
• Channels number reading and setting.
• On / Off identification
This command is used to identify the projector you want to get access to (the identification happens by swit-
12.0 Led temperature
13.0 Temperature of led drivers
14.0 Body Temperature ( only Polar versions)
15.0 Heating Power ( only Polar versions )
16.0 Default setting
17.0 RDM functions
11.0 Dimmer ( Monochromatic )