Daikin FXDQ63A3VEB [3/18] Safety precautions
![Daikin FXDQ15A3VEB [3/18] Safety precautions](/views2/1704002/page3/bg3.png)
English 1
VRV SYSTEM Inverter Air Conditioners Installation manual
CONTENTS
1. SAFETY PRECAUTIONS................................................ 1
2. BEFORE INSTALLATION................................................ 2
3. SELECTING INSTALLATION SITE ................................. 3
4. PREPARATIONS BEFORE INSTALLATION ................... 4
5. INDOOR UNIT INSTALLATION....................................... 5
6. REFRIGERANT PIPING WORK ..................................... 5
7. DRAIN PIPING WORK.................................................... 7
8. INSTALLING THE DUCT................................................. 8
9. ELECTRIC WIRING WORK ............................................ 9
10. WIRING EXAMPLE ....................................................... 10
11. FIELD SETTING AND TEST RUN ................................ 13
12. WIRING DIAGRAM ....................................................... 14
The original instructions are written in English. All other lan-
guages are translations of the original instructions.
1. SAFETY PRECAUTIONS
Please read these “SAFETY PRECAUTIONS” carefully before
installing air conditioning equipment and be sure to install it cor-
rectly.
After completing installation, conduct a trial operation to check
for faults and explain to the customer how to operate the air con-
ditioner and take care of it with the aid of the operation manual.
Ask the customer to store the installation manual along with the
operation manual for future reference.
This air conditioner comes under the term “appliances not
accessible to the general public”.
Meaning of WARNING and CAUTION notices
WARNING ............. Failure to follow these instructions
properly may result in personal injury
or loss of life.
CAUTION .............. Failure to observe these instructions
properly may result in property dam-
age or personal injury, which may be
serious depending on the circum-
stances.
WARNING
•
Ask your dealer or qualified personnel to carry out installation
work.
Do not attempt to install the air conditioner yourself.
Improper
installation may result in water leakage, electric shocks or
fire.
•
Install the air conditioner in accordance with the instructions
in this installation manual.
Improper installation may result in water leakage, electric
shocks or fire.
•
Consult your local dealer regarding what to do in case of
refrigerant leakage. When the air conditioner is to be
installed in a small room, it is necessary to take proper mea-
sures so that the amount of any leaked refrigerant does not
exceed the concentration limit in the event of a leakage.
Otherwise, this may lead to an accident due to oxygen deple-
tion.
•
Be sure to use only the specified accessories and spare
parts for installation work.
Failure to use the specified parts may result in the unit falling,
water leakage, electric shocks or fire.
•
Install the air conditioner on a foundation strong enough to
withstand the weight of the unit.
A foundation of insufficient strength may result in the equip-
ment falling and causing injury.
•
Carry out the specified installation work after taking into
account strong winds, typhoons or earthquakes.
Failure to do so during installation work may result in the unit
falling and causing accidents.
•
Make sure that a separate power supply circuit is provided
for this unit and that all electrical work is carried out by qual-
ified personnel according to local laws and regulations and
this installation manual.
An insufficient power supply capacity or improper electrical
construction may lead to electric shocks or fire.
•
Make sure that all wiring is secured, the specified wires are used,
and that there is no strain on the terminal connections or wires.
Improper connections or securing of wires may result in
abnormal heat build-up or fire.
•
When wiring the power supply and connecting the remote
controller wiring and transmission wiring, position the wires
so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in elec-
tric shocks, fire or the terminals overheating.
•
If the supply cord is damaged, it must be replaced by the
manufacturer, a service agent or similarly qualified persons
in order to avoid a hazard.
•
If refrigerant gas leaks during installation, ventilate the area
immediately.
Toxic gas may be produced if the refrigerant comes into con-
tact with fire.
•
After completing installation, check for refrigerant gas leakage.
Toxic gas may be produced if the refrigerant gas leaks into
the room and comes into contact with a source of fire, such
as a fan heater, stove or cooker.
•
Be sure to switch off the unit before touching any electrical
parts.
•
Do not touch the switch with wet fingers.
Touching the switch with wet fingers can cause electric shock.
•
Be sure to earth the air conditioner.
Do not earth the unit to a utility pipe, lightning conductor or
telephone earth lead.
Imperfect earthing may result in electric shocks or fire.
A high surge current from lightning or other sources may
cause damage to the air conditioner.
•
Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in elec-
tric shocks or fire.
CAUTION
•
While following the instructions in this installation manual,
install drain piping to ensure proper drainage and insulate
piping to prevent condensation.
Improper drain piping may result in indoor water leakage and
property damage.
•
Install the indoor and outdoor units, power cord and connect-
ing wires at least 1 meter away from televisions or radios to
prevent picture interference and noise.
(Depending on the incoming signal strength, a distance of
1 meter may not be sufficient to eliminate noise.)
•
Remote controller (wireless kit) transmitting distance can be
shorter than expected in rooms with electronic fluorescent
lamps (inverter or rapid start types).
Install the indoor unit as far away from fluorescent lamps as
possible.
•
Only handle the indoor unit with gloves.
4PEN325876-1F.book Page 1 Thursday, April 20, 2017 8:20 AM
Содержание
- Installation manual 1
- System inverter air conditioners 1
- Daikin industries czech republic s r o 2
- En60335 2 4 2
- Fxdq15a3veb fxdq20a3veb fxdq25a3veb fxdq32a3veb fxdq40a3veb fxdq50a3veb fxdq63a3veb 2
- Machinery 2006 42 ec electromagnetic compatibility 2014 30 eu 2
- P481419 1 2
- P481419 1_fxdq15 63a3veb fm page 1 monday april 24 2017 10 01 am 2
- Tetsuya baba managing director pilsen 2nd of may 2017 2
- Contents 3
- Safety precautions 3
- 1 precautions 4
- 2 accessories 4
- 3 optional accessories 4
- Before installation 4
- For the following items take special care during construction and check after installation is finished 4
- Selecting installation site 5
- Preparations before installation 6
- In case of back side in case of bottom side 7
- Indoor unit installation 7
- Refrigerant piping work 7
- Drain piping work 9
- Installing the duct 10
- 1 general instructions 11
- 2 specifications for field supplied fuses and wire 11
- 3 electrical characteristics 11
- A circuit breaker capable of shutting down power supply to the entire system must be installed 11
- All field supplied parts and materials electric works must conform to local codes 11
- All wiring must be performed by an authorized electrician 11
- Be sure to ground the air conditioner 11
- Do not the earth wire should come in contact with gas pipes water pipes lightning rods or telephone earth wires 11
- Do not turn on the power supply circuit breaker or earth leak age breaker until all other work is done 11
- Electric wiring work 11
- English 9 11
- For details on hooking up the remote controller refer to the remote controller installation manual 11
- Gas pipes gas leaks can cause explosions and fire 11
- Length of the transmission wiring and remote controller wiring 11
- Mca minimum circuit amps a mfa max fuse amps a kw fan motor output kw fla full load amps a 11
- Power related 11
- Refer to the installation manual attached to the outdoor unit for the size of power supply wiring connected to the outdoor unit the capacity of the circuit breaker and switch and wiring instructions 11
- See also the wiring diagram plate attached to the control box lid when laying electrical wiring 11
- Shows only in case of protected pipes use h07rn f in case of no protection 2 insulated thickness 1mm or more 3 if the wiring is in a place where people it can be easily touched by people install an earth leakage breaker to pre vent electric shock 4 when using an earth leakage breaker make sure to select one useful also to protection against overcurrent and short circuit when using an earth leakage breaker only for earth device make sure to use a wiring interrupter together 11
- Shut off the power before doing any work 11
- Telephone earth wire and lightning rods the ground potential when struck by lightning gets extremely high 11
- The length of the transmission wiring and remote controller wiring are as follows 11
- This system consists of multiple indoor units mark each indoor unit as unit a unit b and be sure the terminal board wiring to the outdoor unit and bs unit are properly matched if wiring and piping between the outdoor unit and an indoor unit are mismatched the system may cause a malfunction 11
- To avoid short circuiting the power supply wire be sure to use insulated terminals 11
- Use copper wire only 11
- Water pipes they cannot be grounded if hard vinyl pipes are used 11
- 1 how to connect wirings 12
- Wiring example 12
- Precautions when laying power supply wiring 13
- Wiring example 13
- 2 control by 2 remote controllers con trolling 1 indoor unit by 2 remote controllers 14
- 3 remote control forced off and on off operation 14
- 4 centralized control 14
- Field setting and test run 14
- 1 setting the static pressure selection 15
- 2 remote control setting 15
- 3 setting the filter sign display interval 15
- 4 settings for separately sold accessories 15
- Field setting and test run 15
- Field settings may have to be performed using the remote controller depending on the type of installation 15
- English 16
- Unified wiring diagram legend 16
- Wiring diagram 16
Похожие устройства
- Daikin FXDQ63A3VEB Технические данные
- MEAN WELL OWA-60E-12 Инструкция по эксплуатации
- MEAN WELL OWA-60E-12 Инструкция язык EN
- MEAN WELL OWA-60E-12 Datasheet
- MEAN WELL OWA-60E-12 Документация
- MEAN WELL OWA-60E-15 Инструкция по эксплуатации
- MEAN WELL OWA-60E-15 Инструкция язык EN
- MEAN WELL OWA-60E-15 Datasheet
- MEAN WELL OWA-60E-15 Документация
- MEAN WELL OWA-60E-20 Инструкция по эксплуатации
- MEAN WELL OWA-60E-20 Инструкция язык EN
- MEAN WELL OWA-60E-20 Datasheet
- MEAN WELL OWA-60E-20 Документация
- MEAN WELL OWA-60E-24 Инструкция по эксплуатации
- MEAN WELL OWA-60E-24 Инструкция язык EN
- MEAN WELL OWA-60E-24 Datasheet
- MEAN WELL OWA-60E-24 Документация
- MEAN WELL OWA-60E-30 Инструкция по эксплуатации
- MEAN WELL OWA-60E-30 Инструкция язык EN
- MEAN WELL OWA-60E-30 Datasheet