MEAN WELL PWM-120-36 [3/8] Do not connect dim to v

MEAN WELL PWM-120-36 [3/8] Do not connect dim to v
DIMMING OPERATION
Applying additive 0 ~ 10VDC
Applying additive 10V PWM signal (frequency range 100Hz ~ 3KHz):
LED Strips
LED Strips
+V
-V
DIM+
DIM-
+
+
+
+
-
-
-
-
DO NOT connect "DIM- to -V"
Additive Voltage
+V
-V
DIM+
DIM-
+
-
DO NOT connect "DIM- to -V"
Additive PWM signal
0V 1V
0.6V
6%
1V
10%
2V 3V 4V 5V 6V 7V 8V 9V 10V
20%
30%
40%
50%
60%
70%
80%
90%
100%
0%
10%20% 30% 40% 50% 60% 70% 80% 90% 100%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Dimming input: Additive voltage
Duty cycle of additive 10V PWM signal dimming input
Dimming principle for PWM style output
Apply one of the three methodologies between DIM+ and DIM-: 0 ~ 10VDC, or 10V PWM signal or resistance.
Dimming source current from power supply: 100 A (typ.) μ
PWM-120
ON
OFF
T
ON
T
Output DC current
Io=0A
Output PWM frequency : 1.47KHz fixed (Typ.)
Duty cycle(%) = ×100%
T
ON
T
Dimming is achieved by varying the duty cycle of the output current.
3 in 1 dimming function (for Blank-Type)
120W PWM Output LED Driver
PWM-120 series
File Name:PWM-120-SPEC 2017-08-04
10%
0.15%
0.15%
10%
10%
0%
Duty cycle of output current (%)
Duty cycle of output current (%)
AC/N(Blue)
AC/L(Brown)
* DIM+ for Blank-Type
DA+ for DA-type
* *DIM- for Blank-Type
DA- for DA-type
+V(Red)
-V(Black)
DIM+(Blue)*
DIM-(White)**