Daikin FXVQ500MY16 [31/54] Ftks25d ftks35d

Daikin FXVQ500MY16 [31/54] Ftks25d ftks35d
Outdoor Units
Outdoor Unit Lineup
Cooling Only / Heat Pump
13 14
Outdoor Unit Lineup
The outdoor unit capacity is up to 60 HP in increment of 2 HP.
VRV IV outdoor unit offers a higher capacity of up to 60 HP, responding to the needs of large-sized building.
The single outdoor unit has only 2 different shapes and dimensions, not only simplifying the design process, but also bringing the
system flexibility to a new level.
With the outdoor unit capacity increased in increment of 2 HP, customers' needs can be precisely met.
Outdoor units with anti-corrosion specifications (-E type on request) are designed specifically for use in areas which are subject to
salt damage and atmospheric pollution.
12, 14, 16 HP
RX(Y)Q36THY1(E)
RX(Y)Q40THY1(E)
RX(Y)Q12THY1(E)
RX(Y)Q14THY1(E)
RX(Y)Q16THY1(E)
RX(Y)Q6TY1(E)
RX(Y)Q8TY1(E)
RX(Y)Q10TY1(E)
RX(Y)Q12TY1(E)
RX(Y)Q18TY1(E)
RX(Y)Q20TY1(E)
RX(Y)Q22TSY1(E)
RX(Y)Q24TSY1(E)
RX(Y)Q42TSY1(E)
RX(Y)Q44TSY1(E)
RX(Y)Q46TSY1(E)
RX(Y)Q48TSY1(E)
RX(Y)Q50TSY1(E)
RX(Y)Q14TY1(E)
RX(Y)Q16TY1(E)
RX(Y)Q18TNY1(E)
RX(Y)Q20TNY1(E)
18, 20, 22, 24, 26, 28, 30, 32 HP
36, 40 HP
42, 44 HP 46, 48, 50, 52, 54, 56, 58, 60 HP
Triple Outdoor Units
Triple Outdoor Units
Triple Outdoor Units
Double Outdoor Units
6, 8, 10, 12 HP 14, 16 HP 22, 24, 26 HP
28, 30, 32 HP 34, 36 HP
38, 40 HP
18, 20 HP
22, 24 HP
26, 28, 30, 32 HP 34, 36, 38, 40 HP
Single Outdoor Units
Double Outdoor Units
Single Outdoor Units
Double Outdoor Units Double Outdoor Units
High-COP Type
Standard Type
Space Saving Type
RX(Y)Q34THY1(E)
RX(Y)Q38THY1(E)
RX(Y)Q28TNY1(E)
RX(Y)Q30TNY1(E)
RX(Y)Q32TNY1(E)
RX(Y)Q22TNY1(E)
RX(Y)Q24TNY1(E)
RX(Y)Q26TNY1(E)
RX(Y)Q34TNY1(E)
RX(Y)Q36TNY1(E)
RX(Y)Q38TNY1(E)
RX(Y)Q40TNY1(E)
RX(Y)Q42TNY1(E)
RX(Y)Q44TNY1(E)
34, 38 HP
42, 44, 46, 48, 50 HP
46, 48, 50 HP42, 44 HP
18, 20 HP
RX(Y)Q46TNY1(E)
RX(Y)Q48TNY1(E)
RX(Y)Q50TNY1(E)
RX(Y)Q52TNY1(E)
RX(Y)Q54TNY1(E)
RX(Y)Q56TNY1(E)
RX(Y)Q58TNY1(E)
RX(Y)Q60TNY1(E)
RX(Y)Q18THY1(E)
RX(Y)Q20THY1(E)
RX(Y)Q22THY1(E)
RX(Y)Q24THY1(E)
RX(Y)Q26THY1(E)
RX(Y)Q28THY1(E)
RX(Y)Q30THY1(E)
RX(Y)Q32THY1(E)
RX(Y)Q42THY1(E)
RX(Y)Q44THY1(E)
RX(Y)Q46THY1(E)
RX(Y)Q48THY1(E)
RX(Y)Q50THY1(E)
RX(Y)Q34TSY1(E)
RX(Y)Q36TSY1(E)
RX(Y)Q38TSY1(E)
RX(Y)Q40TSY1(E)
RX(Y)Q26TSY1(E)
RX(Y)Q28TSY1(E)
RX(Y)Q30TSY1(E)
RX(Y)Q32TSY1(E)
Lineup
HP
High-COP Type
Standard Type
Space Saving Type
Mo/C New Lineup
Residential Indoor Units
with connection to BP units
Indoor Unit Lineup
35 36
Indoor Unit Lineup
Wall Mounted indoor units achieve quiet sound
levels of 22 dB (A) during cooling operation.
Intelligent Eye with its infrared sensor
automatically controls air conditioner operation
according to human movement in a room. When
there is no movement, it adjusts the temperature
by 2˚C for energy savings.
3-D Airflow
combines Vertical
and Horizontal
Auto-Swing to
circulate air to every
part of a room for
uniform cooling of even
large spaces.
* This function is available for
FTK(X)S50/60/71F.
FTK(X)S20/25
37/25/22 dB
(A)
FTK(X)S35
39/26/23 dB (A)
FTK(X)S50
43/34/31 dB (A)
FTK(X)S60
45/36/33 dB (A)
FTK(X)S71
46/37/34 dB (A)
(H/L/SL)
When you are in the room
When you go out
A uniform temperature
is achieved throughout
the entire room.
Stylish flat panel harmonises with your interior décor
Wall Mounted Type
Titanium apatite is a photocatalytic material with
high adsorption power. Titanium apatite also
effectively adsorbs and decomposes bacteria
across its entire surface. The photocatalyst is
activated simply by exposure to light.
These filters are not medical devices. Benefits
such as the adsorption and decomposition of
bacteria are only effective for substances that are
collected on and in direct contact with the Titanium
Apatite Photocatalytic Air-Purifying Filter.
Bacteria Removal Test
Testing method: dropping method
Result certificate: No. 012553-1 and 012553-2
Testing organisation: Japan Spinners Inspecting Foundation
Titanium Apatite
Photocatalytic
Air-purifying Filter
Air filter
Catches dust
Slim and smooth design
suits your shallow ceiling
Signals from the wireless remote controller are
transmitted to the signal receiver.
240 mm
200 mm
Only 700 mm
FDKS-EA
CDXS-EA
Dimensions (H x W x D)
Weight
Airflow rate (H)
External static pressure
200 x 700 x 620 mm
21 kg
8.7 m
3
/min
30 Pa
200 x 900 x 620 mm
25 kg
40 Pa
FDKS25EA FDKS35EA
FDKS25CA
FDKS35CA
CDXS25EA CDXS35EA
FDXS25C
FDXS35C
9.5 m
3
/min 10 m
3
/min
35/31/29 dB (A)
35/31/29 dB (A)
FDXS50
37/33/31 dB (A)
FDXS60
38/34/32 dB (A)
(H/L/SL)
Low operation sound level
Home Leave Operation prevents large rises or falls in
the indoor temperature by continuing operation* while
you are sleeping or out of your home. This means that
an air-conditioned welcome awaits when you wake or
return. It also means that the indoor temperature can
quickly return to your favourite comfort setting.
Models in the FDKS-EA and CDXS-EA series are
only 700 mm in width and 21 kg in weight, so are
easily installed in limited spaces. Just 200 mm in
height, all models can be installed in rooms with
as little as 240 mm depth between the drop
ceiling and ceiling slab, making them ideal for
even shallow ceilings.
Notes:
1. To prevent an increase in operation noise, avoid
installing the air suction grille directly below the
suction chamber.
2. Grilles, piping connections, ducts, and installation
parts should be obtained locally. Slim Ceiling
Mounted Duct type models do not have drain-up
pumps.
3. The signal receiver unit must be located near the
air suction inlet, because the unit includes a
sensor that detects room temperature.
Suction grille
(KDGF19A45)
Option
* Locally obtained parts
AIR
Air suction
grille*
Suction duct*
Signal
receiver
Air discharge duct*
Suspension bolt*
Air discharge grille*
Signal receiver wire
Length
=
1,900 mm
Chamber
AIR
Air filter
* Home Leave Operation can be selected for any temperature from 18 to
32˚C for cooling operation and 10 to 30˚C for heating operation.
* Home Leave Operation function must be set using the remote controller
when going to sleep or leaving the house, and after waking up or returning
home.
Standard accessory
Note: Remote controllers
other than the standard
accessory wireless remote
controller cannot be used.
Great for
hotel use!
Slim Ceiling Mounted Duct Type
FDKS25 FDKS35
C(F)DXS25 C(F)DXS35
FDKS50 FDKS60
* Remote controllers other than the standard accessory wireless remote controller cannot be used.
Standard accessory*
Standard accessory*
Standard
accessory*
Cooling Only
Heat Pump
FDKS25EA / FDKS35EA
FDKS25CA / FDKS35CA
FDKS50C / FDKS60C
CDXS25EA / CDXS35EA
FDXS25C / FDXS35C
FDXS50C / FDXS60C
Cooling Only
Heat Pump
FTKS25D / FTKS35D
FTXS20D / FTXS25E / FTXS35E
Cooling Only
Heat Pump
FTKS50F / FTKS60F / FTKS71F
FTXS50F / FTXS60F / FTXS71F
FTKS50B
Cooling Only
Outdoor Units
Specifications
Heat Pump
59 60
Specifications
High-COP Type
103,000
409,000
120
116,000
461,000
135
32.7
33.3
4-100
108,000
427,000
125
120,000
478,000
140
34.8
35.0
3-100
112,000
444,000
130
125,000
495,000
145
36.9
36.7
3-100
116,000
461,000
135
129,000
512,000
150
39.0
38.4
3-100
120,000
478,000
140
134,000
532,000
156
41.4
40.7
3-100
RXYQ14TY1(E)
RXYQ14TY1(E)
RXYQ14TY1(E)
RXYQ14TY1(E)
RXYQ14TY1(E)
RXYQ16TY1(E)
RXYQ14TY1(E)
RXYQ16TY1(E)
RXYQ16TY1(E)
RXYQ16TY1(E)
RXYQ16TY1(E)
RXYQ16TY1(E)
RXYQ16TY1(E)
RXYQ16TY1(E)
RXYQ18TY1(E)
RXYQ42THY1(E)
RXYQ44THY1(E) RXYQ46THY1(E) RXYQ48THY1(E) RXYQ50THY1(E)
(1,657
X
1,240
X
765)
+
(1,657
X
1,240
X
765)
+
(1,657
X
1,240
X
765)
(1,657
X
1,240
X
765)
+
(1,657
X
1,240
X
765)
+
(1,657
X
1,240
X
765)
285
+
285
+
285
65
10.3
+
10.3
+
10.3
285
+
285
+
285
65
10.3
+
10.3
+
10.4
RXYQ6TY1(E)
RXYQ8TY1(E)
RXYQ10TY1(E)
RYXQ12TY1(E) RXYQ14TY1(E) RXYQ16TY1(E)
233
+
233
+
233 233
+
233
+
233
(1,657
X
1,240
X
765)
+
(1,657
X
1,240
X
765)
+
(1,657
X
1,240
X
765)
285
+
285
+
285
65
10.3
+
10.4
+
10.4
233
+
233
+
233
(1,657
X
1,240
X
765)
+
(1,657
X
1,240
X
765)
+
(1,657
X
1,240
X
765)
285
+
285
+
285
66
10.4
+
10.4
+
10.4
233
+
233
+
233
(1,657
X
1,240
X
765)
+
(1,657
X
1,240
X
765)
+
(1,657
X
1,240
X
765)
285
+
285
+
300
66
10.4
+
10.4
+
11.7
233
+
233
+
233
13,800
54,600
16.0
15,500
61,400
18.0
3.63
3.99
20-100
19,300
76,400
22.4
21,500
85,300
25.0
5.21
5.69
20-100
24,100
95,500
28.0
27,100
107,000
31.5
7.29
7.29
16-100
28,800
114,000
33.5
32,300
128,000
37.5
9.01
9.06
15-100
34,400
136,000
40.0
38,700
154,000
45.0
10.9
11.1
11-100
38,700
154,000
45.0
43,000
171,000
50.0
13.0
12.8
10-100
185
55
5.9
185
56
5.9
195
57
6.0
195
59
6.3
285
60
10.3
285
61
10.4
2.4
X
1 3.4
X
1 4.1
X
1 5.2
X
1
119 157 165 178 233 233
(2.9
X
1)
+
(3.3
X
1) (3.6
X
1)
+
(3.7
X
1)
Standard Type
(2.9
X
1)
+
(3.3
X
1)
+
(2.9
X
1)
+
(3.3
X
1)
+
(2.9
X
1)
+
(3.3
X
1)
(2.9
X
1)
+
(3.3
X
1)
+
(2.9
X
1)
+
(3.3
X
1)
+
(3.6
X
1)
+
(3.7
X
1)
(2.9
X
1)
+
(3.3
X
1)
+
(3.6
X
1)
+
(3.7
X
1)
+
(3.6
X
1)
+
(3.7
X
1)
(3.6
X
1)
+
(3.7
X
1)
+
(3.6
X
1)
+
(3.7
X
1)
+
(3.6
X
1)
+
(3.7
X
1)
(3.6
X
1)
+
(3.7
X
1)
+
(3.6
X
1)
+
(3.7
X
1)
+
(4.4
X
1)
+
(4.0
X
1)
1,657
X
930
X
765 1,657
X
930
X
765 1,657
X
930
X
765 1,657
X
930
X
765
1,657
X
1,240
X
765
1,657
X
1,240
X
765
3-phase 4-wire system, 380–415 V, 50 Hz
3-phase 4-wire system, 380–415 V, 50 Hz
Hermetically Sealed Scroll Type
Hermetically Sealed Scroll Type
19.1
(Brazing)
41.3
(Brazing)
19.1
(Brazing)
41.3
(Brazing)
19.1
(Brazing)
41.3
(Brazing)
19.1
(Brazing)
41.3
(Brazing)
19.1
(Brazing)
41.3
(Brazing)
12.7
(Brazing)
19.1
(Brazing)
9.5
(Brazing)
22.2
(Brazing)
28.6
(Brazing)
-5 to 43
-20 to 15.5
R-410A
-5 to 43
-20 to 15.5
R-410A
Note: 1. Models with (E) feature components treated for heat and rust corrosion resistance, such as external panels, fan motor, and electric
component box, in addition to the fins of the heat exchanger. These models are designed specifically for use in areas which are
subject to salt damage and atmospheric pollution. Please contact Daikin for more information.
2. Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27℃DB, 19WB, Outdoor temp.: 35DB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Heating: Indoor temp.: 20℃DB, Outdoor temp.: 7DB, 6WB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Note: 1. Models with (E) feature components treated for heat and rust corrosion resistance, such as external panels, fan motor, and electric
component box, in addition to the fins of the heat exchanger. These models are designed specifically for use in areas which are
subject to salt damage and atmospheric pollution. Please contact Daikin for more information.
2. Specifications are based on the following conditions;
•Cooling: Indoor temp.: 27℃DB, 19WB, Outdoor temp.: 35DB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Heating: Indoor temp.: 20℃DB, Outdoor temp.: 7DB, 6WB, Equivalent piping length: 7.5 m, Level difference: 0 m.
•Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Ivory white (5Y7.5/1)
Ivory white (5Y7.5/1)
MODEL
Power supply
Power
consumption
Capacity control
Compressor
Dimensions (H
×
W
×
D)
Machine weight
Sound level
Refrigerant
Piping
connections
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
kW
kW
%
kg
dB(A)
ºCDB
ºCWB
kg
kW
m³/min
mm
Charge
Type
Type
Liquid
Gas
mm
mm
Combination units
Cooling capacity
Heating capacity
Motor output
Airflow rate
Operation
range
Cooling
Heating
Cooling
Heating
MODEL
Power supply
Power
consumption
Capacity control
Compressor
Dimensions (H
×
W
×
D)
Machine weight
Sound level
Refrigerant
Piping
connections
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
kW
kW
%
kg
dB(A)
ºCDB
ºCWB
kg
kW
m³/min
mm
Charge
Type
Type
Liquid
Gas
mm
mm
Combination units
Cooling capacity
Heating capacity
Motor output
Airflow rate
Operation
range
Cooling
Heating
Cooling
Heating
Casing colour
Casing colour

Содержание