Daikin FXVQ500MY16 [6/54] Multiple advanced features ensuring more accurate test operation and stable system

Daikin FXVQ500MY16 [6/54] Multiple advanced features ensuring more accurate test operation and stable system
Excellent Operation Performance
03 04
Main Features
Higher Coefficient of Performance (COP)
Comfort
Ease of installation
Improve heat exchanger
efficency, helps to reduced
operation sound.
Lower operation sound
*12 HP of VRV IV improves more compact
design and more saving space than VRV III
*Cooling operation conditions: Indoor temp. of
27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB.
0
3
3.5
4
4.5
6 HP
8 HP
10 HP 12 HP
14 HP
16 HP
18 HP
*
4.30
3.84
3.72
3.67
3.46
3.25
4.41
Enhanced Lineup to 3 types
Energy saving
Peak in outdoor temperaturePeak in outdoor temperaturePeak in outdoor temperature
Enable night mode Enable night mode Enable night mode
Outdoor PCB automatically memorises the time when
the peak outdoor temperature appears. It will enable
quiet operation mode after 8 h
*1
, and return to normal
mode after it keeps for 9 h
*2
.
*1 8 h is the initial setting with 6 h or 10 h also available.
*2 9 h is the initial setting with 8 h or 10 h also available.
Notes: · This function is available in setting at site.
· The operating sound in quiet operation mode is the actual value
measured by our company.
· The relationship of outdoor temperature (load) and time shown
above is just an example.
Streamlined air grille
It promotes the discharge of
swirling airflow, further
reducing the
pressure loss.
Streamlined scroll fan
The sharp edge of each fan blade
has a certain curvature, reducing
both the vibration and the pressure
loss.
Streamlined
scroll fan
Illustrated
fan
Operating
sound (dB)
Load
(%)
Capacity
(%)
Night mode
min.
40 dB(A)
8 hrs
8:00
50
60
50
100
0
40
57
12:00 16:00 20:00 0:00
4:00
8:00
9 hrs
VRV IV VRV IV
6 HP 8 HP 10 HP 12 HP
57
55 56 57 59
57 58 60
1
˜
2 dB(A) reduction than
conventional model
Sound level(dB(A))
Compact & lightweight design
Highly-integrated VRV
system offers compact
outdoor units to achieve
maximum utilisation of the
installation space.
Installation
Space
0.71 m
2
25
%
Decrease
Product
Weight
195 kg
32
%
Decrease
Enables further energy saving
12 HP-50 HP with 4 new models lineup
Installation Space
Product Weight
2.13 m
2
1.66 m
2
555 kg490 kg
10
%
Increase
Energy
Saving
20 HP
Offers higher capacity of up to 60 HP
6 HP-60 HP with 3 new models lineup
3.94 3.94
Product Weight 490 kg
14
%
Decrease
22
%
Decrease
Installation Space
1.66 m
2
380 kg
1.42 m
2
Up to
60 HP
Standard Type
20 HP
New series with compact & lightweight design
18 HP-50 HP with 17 new models lineup
320 kg
0.95 m
2
3.11
43
%
Decrease
35
%
Decrease
Compact
Design
Space Saving Type
20 HP
VRV
12 HP
VRV
12 HP
12 HP
12 HP
High-COP Type
COP during cooling operation
COP during cooling operation
3.94
Product Weight 490 kg
Installation Space
1.66 m
2
COP during cooling operation
4.353.94
Nighttime quiet operation function
Without increasing operation sound, advanced
analytic technologies are utilised to optimise fan
design and increase airflow rate and high external
static pressure.
Large airflow, high static pressure and
quiet technology
1,240 mm
765
mm
765
mm
930 mm
Lineup
HP
High-COP Type
Standard Type
Space Saving Type
Mo/C New Lineup
Product
Weight
285 kg
Installation
Space
0.95 m
2
Cooling
Operation
COP
VRV
VRV
VRV
Excellent Operation Performance
03 04
Main Features
Higher Coefficient of Performance (COP)
Comfort
Ease of installation
Improve heat exchanger
efficency, helps to reduced
operation sound.
Lower operation sound
*12 HP of VRV IV improves more compact
design and more saving space than VRV III
*Cooling operation conditions: Indoor temp. of
27ºCDB, 19ºCWB, and outdoor temp. of 35ºCDB.
0
3
3.5
4
4.5
6 HP
8 HP
10 HP 12 HP
14 HP
16 HP
18 HP
*
4.30
3.84
3.72
3.67
3.46
3.25
4.41
Enhanced Lineup to 3 types
Energy saving
Peak in outdoor temperaturePeak in outdoor temperaturePeak in outdoor temperature
Enable night mode Enable night mode Enable night mode
Outdoor PCB automatically memorises the time when
the peak outdoor temperature appears. It will enable
quiet operation mode after 8 h
*1
, and return to normal
mode after it keeps for 9 h
*2
.
*1 8 h is the initial setting with 6 h or 10 h also available.
*2 9 h is the initial setting with 8 h or 10 h also available.
Notes: · This function is available in setting at site.
· The operating sound in quiet operation mode is the actual value
measured by our company.
· The relationship of outdoor temperature (load) and time shown
above is just an example.
Streamlined air grille
It promotes the discharge of
swirling airflow, further
reducing the
pressure loss.
Streamlined scroll fan
The sharp edge of each fan blade
has a certain curvature, reducing
both the vibration and the pressure
loss.
Streamlined
scroll fan
Illustrated
fan
Operating
sound (dB)
Load
(%)
Capacity
(%)
Night mode
min.
40 dB(A)
8 hrs
8:00
50
60
50
100
0
40
57
12:00 16:00 20:00 0:00
4:00
8:00
9 hrs
VRV IV VRV IV
6 HP 8 HP 10 HP 12 HP
57
55 56 57 59
57 58 60
1
˜
2 dB(A) reduction than
conventional model
Sound level(dB(A))
Compact & lightweight design
Highly-integrated VRV
system offers compact
outdoor units to achieve
maximum utilisation of the
installation space.
Installation
Space
0.71 m
2
25%
Decrease
Product
Weight
195 kg
32%
Decrease
Enables further energy saving
12 HP-50 HP with 4 new models lineup
Installation Space
Product Weight
2.13 m
2
1.66 m
2
555 kg490 kg
10%
Increase
Energy
Saving
20 HP
Offers higher capacity of up to 60 HP
6 HP-60 HP with 3 new models lineup
3.94 3.94
Product Weight 490 kg
14%
Decrease
22%
Decrease
Installation Space
1.66 m
2
380 kg
1.42 m
2
Up to
60 HP
Standard Type
20 HP
New series with compact & lightweight design
18 HP-50 HP with 17 new models lineup
320 kg
0.95 m
2
3.11
43%
Decrease
35%
Decrease
Compact
Design
Space Saving Type
20 HP
VRV
12 HP
VRV
12 HP
12 HP
12 HP
High-COP Type
COP during cooling operation
COP during cooling operation
3.94
Product Weight 490 kg
Installation Space
1.66 m
2
COP during cooling operation
4.353.94
Nighttime quiet operation function
Without increasing operation sound, advanced
analytic technologies are utilised to optimise fan
design and increase airflow rate and high external
static pressure.
Large airflow, high static pressure and
quiet technology
1,240 mm
765
mm
765
mm
930 mm
Lineup
HP
High-COP Type
Standard Type
Space Saving Type
Mo/C New Lineup
Product
Weight
285 kg
Installation
Space
0.95 m
2
Cooling
Operation
COP
VRV
VRV
VRV
Reliable and Stable System
Main Features
09 10
Outdoor unit sequencing technology
Daikin VRV IV system incorporates a simplified and efficient test operation function, not only greatly
accelerating the installation process, but effectively improving the field setting quality as well.
Efficient automatic test operation Automatic sequencing operation
Automatically checks the wirings between
outdoor units and indoor units to confirm
whether there is a defective wiring.
Confirms and corrects the actual piping
length.
Automatically check whether the stop
valve in each outdoor unit is in normal
status to ensure the smooth operation of
air conditioning system.
Automatic check
During start-up, Daikin VRV IV unit sequencing operation will be automatically enabled to
ensure balanced operation of each outdoor unit to improve longevity of equipment and stable operation.
Double backup operation functions responding resiliently to various unexpected situations
Stage 1 Stage 2 Stage 3
Priority: Priority: Priority:
Daikin VRV IV system boasts double backup operation functions, which can secure the use of air
conditioners in this area to the greatest extent by emergently enabling double backup operation functions
even if failure occurs in a set of air conditioning equipment.
In the event of a failure, emergency operation can be conveniently enabled to allow the remaining system
to operate in a limited fashion.
Double backup operation functions
Simplified commissioning and after-sales service
VRV IV system utilises 7-segment
luminous digital tubes to display system
operation information, enabling the
operational state to be visually displayed
whilst facilitating simplified
commissioning and after-sales service.
Function of information display
by luminous digital tube
The VRV configurator is an advanced software solution
that allows for easy system configuration and
commissioning.
less time is required on the roof configuring the outdoor
unit.
multiple systems at different sites can be managed in
exactly the same way, thus offering simplified
commissioning for key accounts.
Initial settings on the outdoor unit can be easily retrieved.
VRV configurator
Unit backup operation function
If malfunction occurs in an outdoor unit...
Emergency operation can be conveniently set and enabled
by the remote controller for indoor unit (for systems
composed of two or more outdoor
units ).
If malfunction occurs in a compressor...
Emergency operation can be easily set and
enabled by the outdoor unit (for a single
outdoor unit system RX(Y)Q14-20TY1 models).
Compressor backup operation function
Multiple advanced features ensuring more accurate test operation and stable system
Wiring
check
Piping
check
Stop valve
check
Simplified
commissioning
Retrieve initial
system settings
Automatic
sequencing
Automatic
sequencing
Automatic
sequencing
Automatic
sequencing
Displays
system
operation
information
directly
Figures out
system
operation
information by
reading light
emitting state
of different
diodes, which
is both
inefficient and
fallible.
7-segment digital display
Conventional LED display

Содержание

Скачать