Wiring diagrams
3TW26476-1
FFQ-B
A1P Printed circuit board
C1 Capacitor (M1F)
F1U Fuse (F5A 250V)
HAP Light emitting diode (service monitor green)
KPR Magnetic relay (M1P)
M1S Motor (swing flap)
M1F Motor (indoor fan)
M1P Motor (drain pump)
Q1M Thermo switch (M1F embedded)
R1T Thermistor (air)
R2T Thermistor (Coil-1)
R3T Thermistor (Coil-2)
S1L Float switch
T1R Transformer (220-240V/22V)
VT1R Phase control circuit
X1M Terminal strip (power)
X2M Terminal strip (control)
RC Signal receiver circuit
TC Signal transmission circuit
Wired remote control
R1T Thermistor (air)
SS1 Selector switch (main/sub)
Receiver / display unit (attached to infrared remote control)
A3P Printed circuit board
A4P Printed circuit board
BS1 Push button (on/off)
H1P Light emitting diode (on-red)
H2P Light emitting diode (timer-green)
H3P Light emitting diode (filter sign-red)
H4P Light emitting diode (defrost-orange)
SS1 Selector switch (main/sub)
SS2 Selector switch (wireless address set)
Indoor unit
Slave
Indoor unit
Master
Wired remote
control
Note) 5
Connecter discrimination colour for components.
Connecter colour for components.
Connecter colour for printed circuit board.
Note) 3
Notes
1. In case using central remote control, connect it to the unit in accordance with the attached instruction manual.
2. X24A is connected when the infrared remote control kit is being used.
3. Remote control model varies according to the combination system, confirm technical materials and catalogs,
etc. before connecting.
4. Ground the shield of the remote controller cord to the indoor unit (in case of using shield wire).
5. Symbols show as follows: RED:Red, BLK:Black, WHT:White, YLW:Yellow, PRP:Purple, GRY:Gray, BLU:Blue
F : Connector
: Wire clamp
: Field wiring
b : Protective earth (screw)
Colours
BLK: Black / WHT: White / RED: Red / YLW: Yellow
Connector for optional parts
X33A Connector (adapter for wiring)
X35A Connector (group control adapter)
X40A Connector (on/off input from outside)
X60A, X61A Connector (interface adapter for sky air series)
Switchbox
In case of simultaneous
operation system.
Remote
controller
To outdoor unit
Note) 3
To outdoor unit
4D010992A
V1, Model
Power supply
1∼50Hz
220V-240V
Fuse
Main switch
Main switch
Fuse
Fuse
NOTES
1 Line voltage wiring
Control circuit wiring
2 All wiring, components and materials to be produced on the site must comply with the applicable local and national codes.
3 Use copper conductors only.
4 See wiring diagrams for details.
5 Install fuse and mainswitch for safety.
6 All field wiring and components must be provided by a licensed electrician.
7 The unit shall be grounded in compilance with the applicable local and national codes.
8 Wiring shown are general points-of-connection guides only and are not intended for or to include all details for a specific
installation.
9 Never share a common power supply with other equipment.
H05VV−U4G
T1, Model
Power supply
1∼50Hz
230V
W1, Model
Power supply
3N∼50Hz
380V-415V
Main switch
•
4-Way Blow Ceiling Mounted Cassette •
R-410A • FFQ25-60B7V1B
18
5
287
• Split - Sky Air • Indoor Units
Содержание
- Table of contents ffq b 1
- Features 2
- Specifications 3
- Specifications 4
- Dimensional drawings 5
- Way blow ceiling mounted cassette 5
- Piping diagrams 6
- F connector 7
- Field wiring b protective earth screw colours blk black wht white red red ylw yellow 7
- In case of simultaneous operation system 7
- In case using central remote control connect it to the unit in accordance with the attached instruction manual 2 x24a is connected when the infrared remote control kit is being used 3 remote control model varies according to the combination system confirm technical materials and catalogs etc before connecting 4 ground the shield of the remote controller cord to the indoor unit in case of using shield wire 5 symbols show as follows red red blk black wht white ylw yellow prp purple gry gray blu blue 7
- Remote controller 7
- Switchbox 7
- Way blow ceiling mounted cassette 7
- Wire clamp 7
- Wired remote control 7
- Wiring diagrams 7
- Sound level 8
- R 410a ffq25 60b7v1b 9
- Sound level 9
- Way blow ceiling mounted cassette 9
- Air flow patterns 10
- Air flow patterns 11
- Air flow patterns 12
- Air flow patterns 13
- Air flow patterns 14
- Air flow patterns 15
- Air flow patterns 16
- Air flow patterns 17
- Accessories 18
- Control systems 19
- R 410a ffq25 60b7v1b 19
- Way blow ceiling mounted cassette 19
- Control systems 20
- R 410a ffq25 60b7v1b 20
- Way blow ceiling mounted cassette 20
- Installation 21
- Safety device settings 21
- Table of contents fcq b7 22
- Features 23
- Specifications 24
- Specifications 25
- Specifications 26
- Specifications 27
- Specifications 28
- Dimensional drawings 29
- Fcq100 125b 9 2 15 0 29
- Fcq35 60b7v1b fcq71 125b7v3b 29
- Fcq35b 6 5 9 2 fcq50b fcq60b 6 5 12 0 fcq71b 9 2 15 0 29
- R 410a 29
- Tw22834 1b 29
- Tw22874 1a 29
- Way blow ceiling mounted cassette inverter controlled 29
- Piping diagrams 30
- Adapter for wiring 31
- Fan operation 31
- G field wiring d terminal f connector h wire clamp b protective earth screw colours blk black wht white red red ylw yellow 31
- Note 3 receiver display unit 31
- Remote control 31
- Simultaneous operation system 31
- Switch box 31
- Terminals for operation indicator 31
- Use copper conductors only 2 when using the central remote control see manual for connection to the unit 3 x24a is connected when the infrared remote control kit is being used 4 the infrared remote control model varies according to the combination system see technical data and catalogues before connecting 31
- Wired remote control 31
- Wiring diagrams 31
- Sound level 32
- Air flow patterns 33
- Air flow patterns 34
- Air flow patterns 35
- Air flow patterns 36
- Branch duct connections 37
- Fcq35 60b7v1b fcq71 125b7v3b 37
- Way blow ceiling mounted cassette inverter controlled 37
- Branch duct connections 38
- Fcq35 60b7v1b fcq71 125b7v3b 38
- Way blow ceiling mounted cassette inverter controlled 38
- Branch duct connections 39
- Fcq35 60b7v1b fcq71 125b7v3b 39
- Way blow ceiling mounted cassette inverter controlled 39
- Branch duct connections 40
- Fcq35 60b7v1b fcq71 125b7v3b 40
- Way blow ceiling mounted cassette inverter controlled 40
- Branch duct connections 41
- Fcq35 60b7v1b fcq71 125b7v3b 41
- Way blow ceiling mounted cassette inverter controlled 41
- Branch duct connections 42
- Fcq35 60b7v1b fcq71 125b7v3b 42
- Way blow ceiling mounted cassette inverter controlled 42
- Accessories 43
- Fcq35 60b7v1b fcq71 125b7v3b 43
- Way blow ceiling mounted cassette inverter controlled 43
- Accessories 44
- Accessories 45
- Control systems 46
- Fcq35 60b7v1b fcq71 125b7v3b 46
- R 410a 46
- Way blow ceiling mounted cassette inverter controlled 46
- Center of gravity 47
- Safety device settings 47
- Installation 48
- Table of contents fcq d 49
- Features 50
- Indoor units r 410a fcq d 50
- Split sky air indoor units 332 50
- Indoor units r 410a fcq d 51
- Specifications 51
- Split sky air indoor units 333 51
- 2 technical specifications 52
- 3 electrical specifications 52
- Indoor units r 410a fcq d 52
- Split sky air indoor units 334 52
- Indoor units r 410a fcq d 53
- Options 53
- Split sky air indoor units 335 53
- 1 dimensional drawing 54
- B arrow view 54
- Bycp125djw1 white 10y 9 0 54
- C arrow view 54
- D arrow view 54
- D033593a 54
- D048825 54
- Decoration panel 54
- Dimensional drawing 54
- Fcq d_e book page 336 thursday june 9 2005 8 23 am 54
- Piping diagram 55
- 1 wiring diagram 56
- 2 external connection diagram 56
- Control circuit wiring 2 all wiring components and materials to be produced on the site must comply with the applicable local and national codes 3 use copper conductors only 4 see wiring diagrams for details 5 install fuse and mainswitch for safety 6 all field wiring and components must be provided by a licensed electrician 7 the unit shall be grounded in compliance with the applicable local and national codes 8 wiring shown are general points of connection guides only and are not intended for or to include all details for a specific installation 9 never share a common power supply with other equipment 56
- D048881 56
- Line voltage wiring 56
- Wiring diagram 56
- 1 sound pressure spectrum 57
- Sound data 57
- Air flow pattern 58
- Indoor units r 410a fcq d 58
- Split sky air indoor units 340 58
- Air flow pattern 59
- Indoor units r 410a fcq d 59
- Split sky air indoor units 341 59
- Air flow pattern 60
- Indoor units r 410a fcq d 60
- Split sky air indoor units 342 60
- Air flow pattern 61
- Indoor units r 410a fcq d 61
- Split sky air indoor units 343 61
- Air flow pattern 62
- Indoor units r 410a fcq d 62
- Split sky air indoor units 344 62
- Air flow pattern 63
- Indoor units r 410a fcq d 63
- Split sky air indoor units 345 63
- Air flow pattern 64
- Indoor units r 410a fcq d 64
- Split sky air indoor units 346 64
- Air flow pattern 65
- Indoor units r 410a fcq d 65
- Split sky air indoor units 347 65
Похожие устройства
- Candy CSO34 106T1/2-07 Техническое описание
- Candy CSO34 106T1/2-07 Руководство пользователя
- Candy CSO4 107T1/2-07 Техническое описание
- Candy CSO4 107T1/2-07 Руководство пользователя
- Candy CSS41062DB3/2-BY Техническое описание
- Candy CSS41062DB3/2-BY Руководство пользователя
- Candy CS34 1052D3\2-BY Техническое описание
- Candy CS34 1052D3\2-BY Руководство пользователя
- Candy CS4 1062D3/2-BY Техническое описание
- Candy CS4 1062D3/2-BY Руководство пользователя
- Candy CSS4 1072D3\2-BY Техническое описание
- Candy CSS4 1072D3\2-BY Руководство пользователя
- Candy EGVF4137TWHB3-BY Техническое описание
- Candy EGVF4137TWHB3-BY Руководство пользователя
- Candy CSS4 1162D3/2-BY Техническое описание
- Candy CSS4 1162D3/2-BY Руководство пользователя
- Candy EGVF44138TWHC-BY Техническое описание
- Candy EGVF44138TWHC-BY Руководство пользователя
- Candy CSS41052DB1/2-07 Техническое описание
- Candy CSS41052DB1/2-07 Руководство пользователя