Daikin FCQ125B7V3B [7/65] Way blow ceiling mounted cassette

Daikin FCQ125B7V3B [7/65] Way blow ceiling mounted cassette
5
Wiring diagrams
3TW26476-1
FFQ-B
A1P Printed circuit board
C1 Capacitor (M1F)
F1U Fuse (F5A 250V)
HAP Light emitting diode (service monitor green)
KPR Magnetic relay (M1P)
M1S Motor (swing flap)
M1F Motor (indoor fan)
M1P Motor (drain pump)
Q1M Thermo switch (M1F embedded)
R1T Thermistor (air)
R2T Thermistor (Coil-1)
R3T Thermistor (Coil-2)
S1L Float switch
T1R Transformer (220-240V/22V)
VT1R Phase control circuit
X1M Terminal strip (power)
X2M Terminal strip (control)
RC Signal receiver circuit
TC Signal transmission circuit
Wired remote control
R1T Thermistor (air)
SS1 Selector switch (main/sub)
Receiver / display unit (attached to infrared remote control)
A3P Printed circuit board
A4P Printed circuit board
BS1 Push button (on/off)
H1P Light emitting diode (on-red)
H2P Light emitting diode (timer-green)
H3P Light emitting diode (filter sign-red)
H4P Light emitting diode (defrost-orange)
SS1 Selector switch (main/sub)
SS2 Selector switch (wireless address set)
Indoor unit
Slave
Indoor unit
Master
Wired remote
control
Note) 5
Connecter discrimination colour for components.
Connecter colour for components.
Connecter colour for printed circuit board.
Note) 3
Notes
1. In case using central remote control, connect it to the unit in accordance with the attached instruction manual.
2. X24A is connected when the infrared remote control kit is being used.
3. Remote control model varies according to the combination system, confirm technical materials and catalogs,
etc. before connecting.
4. Ground the shield of the remote controller cord to the indoor unit (in case of using shield wire).
5. Symbols show as follows: RED:Red, BLK:Black, WHT:White, YLW:Yellow, PRP:Purple, GRY:Gray, BLU:Blue
F : Connector
: Wire clamp
: Field wiring
b : Protective earth (screw)
Colours
BLK: Black / WHT: White / RED: Red / YLW: Yellow
Connector for optional parts
X33A Connector (adapter for wiring)
X35A Connector (group control adapter)
X40A Connector (on/off input from outside)
X60A, X61A Connector (interface adapter for sky air series)
Switchbox
In case of simultaneous
operation system.
Remote
controller
To outdoor unit
Note) 3
To outdoor unit
4D010992A
V1, Model
Power supply
150Hz
220V-240V
Fuse
Main switch
Main switch
Fuse
Fuse
NOTES
1 Line voltage wiring
Control circuit wiring
2 All wiring, components and materials to be produced on the site must comply with the applicable local and national codes.
3 Use copper conductors only.
4 See wiring diagrams for details.
5 Install fuse and mainswitch for safety.
6 All field wiring and components must be provided by a licensed electrician.
7 The unit shall be grounded in compilance with the applicable local and national codes.
8 Wiring shown are general points-of-connection guides only and are not intended for or to include all details for a specific
installation.
9 Never share a common power supply with other equipment.
H05VVU4G
T1, Model
Power supply
150Hz
230V
W1, Model
Power supply
3N50Hz
380V-415V
Main switch
4-Way Blow Ceiling Mounted Cassette
R-410A FFQ25-60B7V1B
18
5
287
Split - Sky Air Indoor Units