Si34-803
Table of Contents iii
2.4 Operation of The Remote Controller’s Inspection /
Test Operation Button ..........................................................................250
2.5 Remote Controller Service Mode .........................................................251
2.6 Remote Controller Self-Diagnosis Function .........................................253
3. Troubleshooting by Indication on the Remote Controller ....................260
3.1 A0” Indoor Unit: Error of External Protection Device............................260
3.2 A1” Indoor Unit: PC Board Defect ........................................................261
3.3 A3” Indoor Unit: Malfunction of Drain Level Control System (S1L) ......262
3.4 A6” Indoor Unit: Fan Motor (M1F) Lock, Overload...............................264
3.5 A7” Indoor Unit: Malfunction of Swing Flap Motor (M1S).....................268
3.6 Abnormal Power Supply Voltage..........................................................270
3.7 A9” Indoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E)........................................................271
3.8 AF” Indoor Unit: Drain Level above Limit .............................................273
3.9 AJ” Indoor Unit: Malfunction of Capacity Determination Device ..........274
3.10 C1” Indoor Unit: Failure of Transmission
(Between Indoor unit PC Board and Fan PC Board)............................275
3.11 C4” Indoor Unit: Malfunction of Thermistor (R2T) for
Heat Exchanger....................................................................................277
3.12 C5” Indoor Unit: Malfunction of Thermistor (R3T) for Gas Pipes .........278
3.13 C6” Indoor Unit: Failure of Combination
(Between Indoor unit PC Board and Fan PC Board)............................279
3.14 C9” Indoor Unit: Malfunction of Thermistor (R1T) for Suction Air.........280
3.15 CC” Indoor Unit: Malfunction of Humidity Sensor System ....................281
3.16 CJ” Indoor Unit: Malfunction of Thermostat Sensor
in Remote Controller ............................................................................282
3.17 E1” Outdoor Unit: PC Board Defect .....................................................283
3.18 E3” Outdoor Unit: Actuation of High Pressure Switch..........................284
3.19 E4” Outdoor Unit: Actuation of Low Pressure Sensor..........................286
3.20 E5 Outdoor Unit: Inverter Compressor Motor Lock.............................288
3.21 E6 Outdoor Unit: STD Compressor Motor Overcurrent/Lock..............290
3.22 E7 Outdoor Unit: Malfunction of Outdoor Unit Fan Motor...................291
3.23 E9” Outdoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E, Y2E)...............................................294
3.24 F3” Outdoor Unit: Abnormal Discharge Pipe Temperature..................296
3.25 F6 Outdoor Unit: Refrigerant Overcharged.........................................297
3.26 H7 Outdoor Unit: Abnormal Outdoor Fan Motor Signal ......................298
3.27 H9” Outdoor Unit: Malfunction of Thermistor (R1T) for Outdoor Air.....299
3.28 J2 Outdoor Unit: Current Sensor Malfunction ....................................300
3.29 J3” Outdoor Unit: Malfunction of Discharge Pipe Thermistor
(R3, R31~33T) .....................................................................................301
3.30 J5” Outdoor Unit: Malfunction of Thermistor (R2T, R7T) for
Suction Pipe .........................................................................................302
3.31 J6” Outdoor Unit: Malfunction of Thermistor (R4T) for
Outdoor Unit Heat Exchanger ..............................................................303
3.32 J7” Outdoor Unit: Malfunction of Liquid Pipe Thermistor (R6T)...........304
3.33 J9” Outdoor Unit: Malfunction of Subcooling Heat Exchanger
Gas Pipe Thermistor (R5T) ..................................................................305
3.34 JA” Outdoor Unit: Malfunction of High Pressure Sensor......................306
3.35 JC” Outdoor Unit: Malfunction of Low Pressure Sensor ......................307
3.36 L4” Outdoor Unit: Malfunction of Inverter Radiating
Fin Temperature Rise...........................................................................308