Pollution Degree
PD 2: Office or Laboratory Environments
Over Voltage Category
OVC II
EMC Emissions
EN 61000-6-3 (Generic Residential)
EN 61204-3 (Low Voltage Power Supplies)
EN 50121-3-2 (EMC for Rolling Stock)
EN 50121-4 (Railway Application Signalling)
- Conducted Emissions
EN 55011 class B (internal filter)
EN 55032 class B (internal filter)
- Radiated Emissions
EN 55011 class B (internal filter)
EN 55032 class B (internal filter)
- Harmonic Current Emissions
EN 61000-3-2, class A
EMC Immunity
EN 50121-3-2 (EMC for Rolling Stock)
EN 50121-4 (Railway Application Signalling)
EN 61000-6-2 (Generic Industrial)
EN 61204-3 (Low Voltage Power Supplies)
- Electrostatic Discharge
Air:
EN 61000-4-2, ±8 kV, perf. criteria A
Contact:
EN 61000-4-2, ±4 kV, perf. criteria A
- RF Electromagnetic Field
EN 61000-4-3, 10 V/m, perf. criteria A
- EFT (Burst)
EN 61000-4-4, ±2 kV, perf. criteria B
- Surge
L to L:
EN 61000-4-5, ±1 kV, perf. criteria B
L to PE:
EN 61000-4-5, ±2 kV, perf. criteria B
- Conducted RF Disturbances
EN 61000-4-6, 10 Vrms, perf. criteria A
- PF Magnetic Field
EN 61000-4-8, 30 A/m, perf. criteria A
- Voltage Dips & Interruptions
230 VAC / 50 Hz:
EN 61000-4-11
30%, 25 periods, perf. criteria C
60%, 10 periods, perf. criteria C
>95%, 1 period, perf. criteria B
>95%, 5 periods, perf. criteria C
20%, 250 periods, perf. criteria C
115 VAC / 60 Hz:
EN 61000-4-11
30%, 25 periods, perf. criteria C
60%, 10 periods, perf. criteria C
>95%, 1 period, perf. criteria B
>95%, 5 periods, perf. criteria C
20%, 250 periods, perf. criteria C
- Voltage Sag Immunity
SEMI F47, criteria A
EMC Specifications
Relative Humidity
95% max. (non condensing)
Temperature Ranges
- Operating Temperature
–40°C to +70°C
Power Derating
- High Temperature
2 %/K above 60°C (at standard operation)
3 %/K above 60°C (at peak power mode)
- Low Input Voltage
3 %/V below 90 VAC (at standard operation)
1.5 %/V below 100 VAC (at peak power mode)
Cooling System
Natural convection (no internal fan, 20 LFM)
Altitude During Operation
2000 m max.
Switching Frequency
60 - 75 kHz (PWM)
Insulation System
Reinforced Insulation
Isolation Test Voltage
- Input to Output, 60 s
4'250 VDC
- Input to Case or PE, 60 s
1'500 VDC
- Output to Case or PE, 60 s
750 VDC
Creepage
- Input to Output
8 mm min.
- Input to Case or PE
4 mm min.
- Output to Case or PE
1.5 mm min.
General Specifications
TIB 080 Series, 80 Watt
All specifications valid at nominal input voltage, full load and +25°C after warm-up time unless otherwise stated.
www.tracopower.com
April 9, 2019