Daikin RXY32MTLE [9/15] 1 never do the following
![Daikin RXY32MTLE [9/15] 1 never do the following](/views2/1708726/page9/bg9.png)
English 4
4. WARNING
4-1 NEVER DO THE FOLLOWING
• Never let the indoor unit or the remote control-
ler get wet.
Do not wash the outdoor unit with water.
Itmaycauseanelectricshockorafire.
• Never use flammable spray such as hair spray,
lacquer or paint near the unit.
It may cause a fire.
• Never touch the air outlet or the horizontal
blades while the swing flap is in operation.
Fingers may become caught or the unit may break
down.
• Never replace a fuse with that of wrong
ampere ratings or other wires when a fuse
blows out.
Use of wire or copper wire may cause the unit to
break down or cause a fire.
•
Never put any objects into the air inlet or outlet.
Objects touching the fan at high operating speed
can be dangerous.
• Never remove the fan guard of the outdoor
unit.
A fan rotating at high speed without the fan guard
is very dangerous.
• Never press the button of the remote control-
ler with a hard, pointed object.
The remote controller may be damaged.
• Never pull or twist the electric wire of the
remote controller.
It may cause the unit to malfunction.
• Never inspect or service the unit by yourself.
Ask a qualified service person to perform this work.
• To prevent refrigerant leak, contact your
Daikin dealer.
When the system is installed and run in a small
room, it is required to keep the concentration of
the refrigerant, if by and chance coming out, bel-
low the limit. Otherwise, oxygen in the room may
be affected, resulting in a serious accident.
• Cut off all electric waves before servicing.
5. OPERATION RANGE
Use the system in the following temperature and
humidity ranges for safe and effective operation.
** –20°~–15°CWB: Range for operation
–15°~15.5°CWB: Range for continuous operation
*To avoid condensation and water dripping out the
unit.
If the temperature or the humidity is beyond these
conditions, safety devices may work and the air con-
ditioner may not operate.
6. OPERATION PROCEDURE
• Operation procedure varies according to the com-
bination of outdoor unit and remote controller.
Read the chapter “What to do before operation”.
• To protect the unit, turn on the main power switch
6 hours before operation.
• If the main power supply is turned off during oper-
ation, operation will restart automatically after the
power turns back on again.
6-1 COOLING, HEATING, AND FAN ONLY
OPERATION
(Refer to figure 4 and 7)
• Changeover cannot be made with a remote con-
troller whose display shows “ ”
(changeover under control).
• When the display “ ” (changeover under
control) flashes, refer to the chapter “Operation
procedure - Setting the master remote controller”.
• The fan may keep on running for about 1 minute
after the heating operation stops.
• The air flow rate may adjust itself depending on
the room temperature or the fan may stop imme-
diately. This is not a malfunction.
FOR SYSTEMS WITHOUT COOL/HEAT
CHANGEOVER REMOTE CONTROL SWITCH
(Refer to figure 4)
Press the operation mode selector button sev-
eral times and select the operation mode of
your choice;
“ ” Cooling operation
“ ” Heating operation
“ ” Fan only operation
Press the on/off button.
The operation lamp lights up and the system
starts operation.
FOR SYSTEMS WITH COOL/HEAT
CHANGEOVER REMOTE CONTROL SWITCH
(Refer to figure 7)
Select operation mode with the cool/heat
changeover remote control switch as follows:
“ ” “ ” Cooling operation
(Refer to figure 7.1)
“ ” “ ” Heating operation
(Refer to figure 7.2)
“”“”Fan only operation
(Refer to figure 7.3)
COOLING HEATING
outdoor temperature –5°~43°CDB –20°~21°CDB**
–20°~15.5°CWB**
indoor temperature 21°~32°CDB 15°~27°CDB
14°~25°CWB
indoor humidity
≤
80%*
1
2
1
01_3P114261-3M_EN.fm Page 4 Thursday, November 6, 2003 7:23 PM
Содержание
- Operation manual 1
- System air conditioner 1
- Contents 6
- Read the following cautions carefully and use your equipment properly 6
- Safety cautions 6
- What to do before opera tion 7
- What to do before operation 7
- Remote controller and changeover switch name and function of each switch and display refer to figure 2 and 3 8
- Remote controller and changeover switch name and function of eachswitch and display 8
- 1 cooling heating and fan only operation refer to figure 4 and 7 9
- 1 never do the following 9
- Operation procedure 9
- Operation range 9
- Warning 9
- 2 program dry operation 10
- 3 adjusting the air flow direction refer to figure 6 only for double flow multi flow corner ceiling suspended and wall mounted 11
- 4 programming start and stop of the system with timer refer to figure 9 11
- 5 setting the master remote con troller for rxy series refer to figure 10 11
- 1 the system does not operate 12
- 6 precautions for group con trol system or two remote con troller control system 12
- Following symptoms are not air conditioner trou bles 12
- Following symptoms are not air conditioner troubles 12
- Optimum operation 12
- 2 cool heat cannot be changed over 13
- 3 fan operation is possible but cooling and heating do not work 13
- 4 the fan strength does not cor respond to the setting 13
- 5 the fan direction does not cor respond to the setting 13
- 6 white mist comes out of a unit 13
- 7 noise of air conditioners 13
- 8 dust comes out of the unit 13
- 10 the outdoor unit fan does not spin 14
- 11 the display show 14
- 12 the compressor in the out door unit does not stop after a short heating operation 14
- 13 the inside of an outdoor unit is warm even when the unit has stopped 14
- 9 the units can give off odours 14
- Trouble shooting 14
- P114261 3m em03a053 15
Похожие устройства
- Electrolux EWW 1290 Руководство пользователя
- Electrolux EWW 14791 W Руководство пользователя
- Electrolux EWW 148540 W Руководство пользователя
- Electrolux EWW 1486 HDW Руководство пользователя
- Electrolux EWW 1649 Руководство пользователя
- Electrolux EWW 16781 W Руководство пользователя
- Electrolux EWW 1686 HDW Руководство пользователя
- Electrolux EWW 1690 Руководство пользователя
- Electrolux EWW 51476 HW Руководство пользователя
- Electrolux EWW 51486 HW Руководство пользователя
- Electrolux EWW 51676 HW Руководство пользователя
- Electrolux EWW 51685 HW Руководство пользователя
- Electrolux EWX 1237 Руководство пользователя
- Electrolux EWX 14550 W Руководство пользователя
- Electrolux NEAT 1200 Руководство пользователя
- Electrolux NEAT 1600 Руководство пользователя
- Electrolux W4130N Руководство пользователя
- Daikin RXY32MTLE Руководство по эксплуатации
- Daikin RXY32MTLE Технические данные
- Daikin RXY32MTLE Руководство по вводу в эксплуатацию