Daikin RXY40MYLE [20/346] Si38 304 specifications

Daikin RXY14MY1 [20/346] Si38 304 specifications
Si38-304 Specifications
Specifications 9
Notes:
+
1 Indoor temp. : 27°CDB, 19.5°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
difference : 0m.
+
2 Indoor temp. : 27°CDB, 19.0°CWB / outdoor temp. : 35°CDB / Equivalent piping length : 7.5m, level
difference : 0m.
+
3 Indoor temp. : 20°CDB / outdoor temp. : 7°CDB, 6°CWB / Equivalent piping length : 7.5m, level
difference : 0m.
Model Name RXY10MY1(E) RXY12MY1(E)
+
1 Cooling Capacity (19.5°CWB)
kcal / h 25,000 30,000
Btu / h 98,700 118,000
kW 28.9 34.5
+
2 Cooling Capacity (19.0°CWB) kW 28.0 33.5
+
3 Heating Capacity
kcal / h 27,000 30,000
Btu / h 108,000 118,000
kW 31.5 34.7
Casing Color
Y1 Ivory White (5Y7.5/1) Ivory White (5Y7.5/1)
Y1E Light Camel (2.5Y6.5/1.5) Light Camel (2.5Y6.5/1.5)
Dimensions: (H×W×D) mm 1600×930×765 1600×1240×765
Heat Exchanger Cross Fin Coil Cross Fin Coil
Comp.
Type Hermetically Sealed Scroll Type Hermetically Sealed Scroll Type
Piston Displacement m³/h 19.36+14.68 19.36+14.68
Number of Revolutions r.p.m 6480, 2900 6480, 2900
Motor Output×Number
of Units
kW (2.75+4.5)×1 (4.2+4.5)×1
Starting Method Direct on Line Direct on Line
Fan
Type Propeller Fan Propeller Fan
Motor Output kW 0.75×1 0.75×1
Air Flow Rate m³/min 180 210
Drive Direct Drive Direct Drive
Connecting
Pipes
Liquid Pipe mm φ12.7 (Brazing Connection) φ15.9 (Brazing Connection)
Gas Pipe mm φ28.6 (Brazing Connection) φ34.9 (Brazing Connection)
Oil Equalizing Pipe mm
Machine Weight kg 235 290
Safety Devices
High Pressure Switch, Fan Driver Overload Protector, Over
Current Relay, Inverter Overload Protector,
Fusible Plugs
High Pressure Switch, Fan Driver Overload Protector, Over
Current Relay, Inverter Overload Protector,
Fusible Plugs
Defrost Method Deicer Deicer
Capacity Control % 14~100 14~100
Refrigerant
Refrigerant Name R22 R22
Charge kg 13.9 15.6
Control Electronic Expansion Valve Electronic Expansion Valve
Refrigerator
Oil
SUNISO 4GSDID-K SUNISO 4GSDID-K
Charge Volume L 1.9+1.6 1.9+1.6
Standard Accessories
Installation Manual, Operation Manual, Connection Pipes,
Clamps
Installation Manual, Operation Manual, Connection Pipes,
Clamps
Drawing No. 4D038972A 4D038973A
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3