Daikin RXYMQ6PVE [13/20] Indoor unit lineup

Daikin RXYMQ6PVE [13/20] Indoor unit lineup
INDOOR UNIT LINEUP
2423
Floor Standing Type
Suitable for perimeter zone air conditioning
Wall hanging
Floor installation
Floor Standing types can be hung on the wall for easier floor
cleaning. Running the piping from the back allows the unit to be
hung on walls. Cleaning under the unit, where dust tends to
accumulate, is considerably easier.
A long-life filter (maintenance free up to one year ) is equipped
as standard accessory.
The adoption of a fibre-less discharge grille featuring an original
design to prevent condensation also helps prevent staining and
makes cleaning easier.
Concealed Floor
Standing Type
Designed to be concealed in the perimeter skirting-wall
Connecting
port
Refrigerant
piping
Applies also to Floor Standing type (FXLQ-MA).
The unit is concealed in skirting-wall of perimeter, that enables
to create high class interior design.
The connecting port faces
downward, greatly facilitating
on-site piping work.
A long-life filter (maintenance
free up to one year ) is equipped
as standard accessory.
FXNQ20MA/FXNQ25MA
FXNQ32MA/FXNQ40MA
FXNQ50MA/FXNQ63MA
FXLQ20MA/FXLQ25MA
FXLQ32MA/FXLQ40MA
FXLQ50MA/FXLQ63MA
Ceiling Suspended
Cassette Type
(50 Hz only)
This thin indoor unit achieves optimum
air distribution, and can be installed
without the need for ceiling cavity
FXUQ71MA
FXUQ100MA
FXUQ125MA
Connection unit
Connection unit is the device for connecting above indoor unit to VRVIII-S.
Depending on installation site requirements or
room conditions, 2-way, 3-way and 4-way
discharge patterns are available.
4-way airflow
from the centre of the store.
The 3-way airflow can distribute
comfortable air throughout the room.
Only one unit is needed to distribute comfortable air
throughout an L-shaped store.
BEVQ-MAVE
Connection unit for indoor unit
Indoor unit
Piping length*
1
Indoor unit
Remote controller
Super wiring (DIII-NET)
Single-phase 220-240 V
power supply
VRV -S series
outdoor unit
Refrigerant piping layout External wiring layout
Notes:
Gas pipe
Liquid
pipe
Model
Maximum piping length
between the BEV unit
and the indoor unit.
FXUQ-MA 5 m
*1
• When connecting centralised-control device, it is
necessary to install an interface adaptor for an
indoor unit (DTA102A52).
• Connection unit BEVQ-MA is necessary for each
indoor unit.
• The refrigerant piping height difference between
the indoor units and the BEV unit must be within
4 m.
• The BEV unit must be installed within a
maximum height difference between indoor units
of 15 m.
• Branching of the refrigerant piping is not
possible downstream of the BEV unit.
BEVQ71MA/BEVQ100MA/BEVQ125MA
Connection unit series indoor units
8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m
3
8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m
3