Daikin REYQ8PY1B [9/19] 1 cooling heating automatic and fan only operation
![Daikin REYQ16PY1B [9/19] 1 cooling heating automatic and fan only operation](/views2/1713624/page9/bg9.png)
English 5
23.
Fan only/air conditioning selector switch
Set the switch to
“”
for fan only operation or to
“”
for heating or cooling operation.
24.
Cool/heat changeover switch
Set the switch to
“”
for cooling operation or to
“”
for heating operation.
25.
Thermistor
It sense the room temperature around the
remote controller.
26.
These button are used when the ventilation unit
are installed (These are optional accessories)
Refer to the operation manual of the ventilation unit.
NOTE
•
Do not place the controller exposed to direct sunlight.
The LCD display may get discolored, failing to dis-
play the data.
• Never pull or twist the electric wire of a remote
controller.
It may cause the unit to malfunction.
• Do not allow sharp or hard items to touch the but-
tons of the remote controller.
The remote controller may be damaged or break-
down may occur.
• In contradistinction to actual operating situations,
the display on figure 2 shows all possible indica-
tions.
• Figure 2 shows the remote controller which is
opened the cover.
• For FXS, FXM, FXL and FXN, the air flow direc-
tion ajust button (22) is not available and the dis-
play (4) shows “NOT AVAILABLE” when pressed.
5. OPERATION RANGE
Use the system in the following temperature and
humidity ranges for safe and effective operation.
NOTE
• Cooling operation:
If the air conditioner is operated continuously
while the indoor temperature is 21°C or below and
the humidity is 80% or over, the interiors of the
indoor units may cause icing and water leakage
may result.
• Heating operation:
The air conditioner may stop operating for the pro-
tection of the machine if the outdoor temperature
is 21°C or over.
6. OPERATION PROCEDURE
• Operation procedure varies according to the com-
bination of outdoor unit and remote controller.
Read the chapter “What to do before operation”.
• To protect the unit, turn on the main power switch
6 hours before operation.
And do not turn off the power supply during the air
conditioning season because of smoothly start
up.
• If the main power supply is turned off during oper-
ation, operation will restart automatically after the
power turns back on again.
6-1 COOLING, HEATING, AUTOMATIC AND
FAN ONLY OPERATION
FOR SYSTEMS WITHOUT COOL/HEAT SELEC-
TOR (Refer to figure 4)
Press the operation mode selector button sev-
eral times and select the operation mode of
your choice;
“”
Cooling operation
“”
Heating operation
“”
Automatic operation
“”
Fan only operation
NOTE
• Automatic operation (REYQ only)
In this operation mode, cool/heat
changeover is automatically conducted.
•
The operation mode cannot be changed with
the remote controller whose display shows
“ ” (changeover under control).
Change the operation mode with the remote
controller whose display does not show
“”.
• When the display
“”
(changeover
under control) flashes, refer to the chapter
“6-5 SETTING THE MASTER REMOTE
CONTROLLER”.
Press the on/off button.
The operation lamp lights up and the system
starts operation.
FOR SYSTEMS WITH COOL/HEAT SELECTOR
(Refer to figure 4 and 7)
Select operation mode with the Cool/Heat
selector as follows:
“ ” “ ” Cooling operation (Refer to figure 7.1)
“ ” “ ” Heating operation (Refer to figure 7.2)
“” “” Fan only operation (Refer to figure 7.3)
Press the on/off button. (Refer to figure 4)
The operation lamp lights up and the system
starts operation.
COOLING HEATING
outdoor temperature
–5°~43°CDB –20°~21°CDB
–20°~15.5°CWB
indoor temperature
21°~32°CDB 15°~27°CDB
14°~25°CWB
indoor humidity
≤
80%
–
1
2
1
2
01_EN_3P201178-2B.fm Page 5 Wednesday, April 25, 2007 3:51 PM
Содержание
- Operation manual 1
- Reyq8py1b reyq10py1b reyq12py1b reyq14py1b reyq16py1b 1
- System air conditioner 1
- Grazie per avere acquistato questo condizionatore d aria daikin prima di utilizzare quest ultimo leggere attentam ente il presente manuale d uso che illustra le modalità di utilizzo corretto e fornisce un supporto nell eventualità di problemi di funzionamento dopo averlo letto conservare il presente manuale per potervi fare riferimento in seguito si veda inoltre il manuale delle istruzioni in dotazione all unità interna per ulteriori dettagli relativi all unità interna conservare il manuale delle istruzioni in dotazione all unità interna con l unità interna in un luogo sicuro dopo aver ricevuto il documento di garanzia dal rivendi tore conservarlo in un luogo sicuro 2
- Hartelijk dank voor uw keuze van een daikin airconditioner lees deze gebruiksaanwijzing zorgvuldig door voordat u de airconditioner in gebruik neemt in de gebruiksaanwijzing kunt u lezen hoe u het apparaat op de juiste manier gebruikt en wat u kunt doen bij storingen bewaar de gebruiksaanwijzing voor het geval u deze in de toekomst nogmaals nodig heeft zie ook de gebruiksaanwijzing behorend bij de binnenunit voor bijzonderheden over de binnenunit bewaar de gebruiksaanwijzing behorend bij de binnenunit samen met deze gebruiksaanwijzing op een veilige plaats nadat u de garantiekaart van de dealer heeft ontvangen deze op een veilige plaats bewaren 2
- Nous vous remercions d avoir acheté ce climatiseur daikin lisez soigneusement ce manuel d utilisation avant d utiliser le climati seur il vous enseignera à utiliser correctement l unité et vous aid era en cas de panne après avoir lu le manuel rangez le en vue d une utilisation ultérieure pour plus de détails concernant l unité intérieure reportez vous également au manuel d utilisation accompagnant l unité intérieure conservez le manuel d utilisation accompagnant l unité intérieure avec ce manuel d utilisation dans un endroit sûr après avoir reçu la carte de garantie du revendeur conservez la dans un endroit sûr 2
- _cv_3p201178 2b fm page 4 wednesday april 25 2007 3 47 pm 4
- Contents 5
- Read the following cautions carefully and use your equipment properly 5
- Safety cautions 5
- 1 refrigerant charge at factory shipment 7
- Arrange the drain hose to ensure smooth drainage incomplete drainage may cause water leakage 7
- Be sure to use the following places a places that can sufficiently withstand the weight of the air conditioner and suppress the operat ing sound and vibration of the air conditioner b places where warm air from the air outlet of the outdoor unit or the operating sound of the out door unit does not annoy neighbors 7
- Caution for installation 7
- Consult with your dealer for electrical work and grounding work 7
- Consult your dealer if the air conditioner in operation generates unusual noise 7
- Do not install the air conditioner in places where flammable gas may leak out leaked gas may accumulate around the unit causing an explosion 7
- Do not locate the remote controller in a spot splashed with water water coming inside the machine may cause elec tric shocks or may damage the internal electronic parts 7
- Do not use the air conditioner in the following places a places with a mist of mineral oil such as cutting oil b locations such as coastal areas where there is a lot of salt in the air c locations such as hot springs resorts where there is a lot of sulfur in the air d locations such as factories where the power voltage varies a lot e in cars boats and other vehicles f locations such as kitchens where oil may splat ter or there is steam in the air g locations where equipment that produces elec tromagnetic waves is found h places with an acid or alkaline mist i places where fallen leaves are accumulated or weeds grow close together 7
- Drainage through drainpipe 7
- Electrical work 7
- English 3 7
- For refrigerant leakage consult your dealer refrigerant leakage in excess of the level of con centration limits may result in oxygen deficiency when the air conditioner is installed in a small room it is necessary to take proper measures so that the amount of any leaked refrigerant will not exceed the limiting concentration even if it leaks 7
- Make sure that the air conditioner is located in a sufficiently ventilated place not surrounded by obstacles 7
- Make sure that the drainpipe is installed prop erly to drain water if no water is discharged from the drainpipe while the air conditioner is cooling operation the drain pipe may be clogged with dust or dirt and water leakage from the indoor units may result stop operating the air conditioner and consult your dealer 7
- Make sure that there are no obstacles close to the outdoor unit obstacles close to the outdoor unit may drop the performance of the outdoor unit or an increase in the operating sound of the outdoor unit 7
- Pay attention to operating sound 7
- Place of installation 7
- Specifications 7
- Take snow protection measures contact your dealer for the details of snow protec tion measures such as the use of a snow protec tion hood 7
- Use a dedicated circuit for the air conditioner 7
- Remote controller and cool heat selector name and function of each switch and display 8
- Remote controller and cool heat selector name and function of each switch and display refer to figure 2 and 3 8
- What to do before operation 8
- 1 cooling heating automatic and fan only operation 9
- Operation procedure 9
- Operation range 9
- 2 program dry operation 10
- 3 adjusting the air flow direction refer to figure 6 only for double flow multi flow corner ceiling suspended and wall mounted 11
- 4 programming start and stop of the system with timer refer to figure 9 11
- 5 setting the master remote con troller 12
- 1 at the beginning of the season 13
- 6 precautions for group con trol system or two remote con troller control system 13
- Optimum operation 13
- Seasonal maintenance 13
- 1 the system does not operate 14
- 2 at the end of the season 14
- 2 it stops sometimes 14
- 3 cool heat cannot be changed over 14
- 4 fan operation is possible but cooling and heating do not work 14
- 5 the fan strength does not cor respond to the setting 14
- 6 the fan direction does not cor respond to the setting 14
- 7 white mist comes out of a unit 14
- Following symptoms are not air conditioner troubles 14
- 10 the units can give off odours 15
- 11 the outdoor unit fan does not spin 15
- 12 the display shows 15
- 13 the compressor or fan in the outdoor unit does not stop 15
- 14 the inside of an outdoor unit is warm even when the unit has stopped 15
- 15 hot air is emitted even though the unit is stopped 15
- 16 does not cool very well 15
- 8 noise of air conditioners 15
- 9 dust comes out of the unit 15
- After sales service and warranty 16
- Trouble shooting 16
Похожие устройства
- Daikin REYQ10PY1B Инструкция по эксплуатации
- Daikin REYQ12PY1B Инструкция по монтажу
- Daikin REYQ8PY1B Спецификация
- Daikin REYQ10PY1B Спецификация
- Daikin REYQ14PY1B Руководство по вводу в эксплуатацию
- Daikin REYQ16PY1B Руководство по вводу в эксплуатацию
- Daikin REYQ12PY1B Инструкция по эксплуатации
- Daikin REYQ14PY1B Инструкция по монтажу
- Daikin REYQ16PY1B Инструкция по монтажу
- Daikin REYQ8PY1B Сервис мануал
- Daikin REYQ10PY1B Сервис мануал
- Ardesto HCP-550RBRM Инструкция по эксплуатации
- Daikin REYQ12PY1B Спецификация
- Daikin REYQ14PY1B Инструкция по эксплуатации
- Daikin REYQ16PY1B Инструкция по эксплуатации
- Daikin REYQ12PY1B Сервис мануал
- Daikin REYQ14PY1B Спецификация
- Daikin REYQ16PY1B Спецификация
- Daikin REYQ16PY1B Сервис мануал
- Daikin REYQ14PY1B Сервис мануал