Systemair ARFEC3510W [12/20] Arden 3500
![Systemair ARFEC3510W [12/20] Arden 3500](/views2/1714195/page12/bgc.png)
Voltage motor: 230V~
Arden 3500
12
*
1
) Low/high airow (2/10V)
*
2
) Sound power (L
WA
) measurements according to ISO 27327-2: 2014, Installation type E.
*
3
) Sound pressure (L
pA
). Conditions: Distance to the unit 5 metres. Directional factor: 2. Equivalent
absorption area: 200 m². At low/high airow (2/10V).
*
4
) ∆t = temperature rise of passing air at maximum heat output and low/high airow (2/10V).
*
5
) Applicable at water temperature 60/40 °C, air temperature, in +18 °C.
*
6
) Applicable at water temperature 40/30 °C, air temperature, in +18 °C.
*
5,6
) See www.frico.net for additional calculations.
Technical specications
1 Ambient, no heat - ARFEC3500 A (IP20)
Item
number
Type Output
[kW]
Airow*
1
[m
3
/h]
Sound
power*
2
[dB(A)]
Sound
pressure*
3
[dB(A)]
Motor
[W]
Amperage
motor
[A]
Weight
[kg]
190544 ARFEC3510A 0 1000/1900 76 43/60 340 2,3 31
190548 ARFEC3515A 0 1550/3000 78 44/62 510 3,2 43
190552 ARFEC3520A 0 2250/3800 79 45/63 670 4,1 56
3 Electrical heat - ARFEC3500 E (IP20)
Item
number
Type Output
steps
[kW]
Airow*
1
[m
3
/h]
∆t
*4
[°C]
Sound
power*
2
[dB(A)]
Sound
pressure*
3
[dB(A)]
Motor
[W]
Amperage
motor
[A]
Voltage [V]
Amperage
[A](heat)
Weight
[kg]
190545 ARFEC3510E09 4,5/9,0 1000/1900 26/14 76 43/60 340 2,3 400V3~/13 35
190549 ARFEC3515E14 6,8/14 1550/3000 26/13 77 44/62 510 3,2 400V3~/19,5 53
190553 ARFEC3520E18 9,0/18 2250/3800 24/14 78 45/63 670 4,1 400V3~/26 65
2 Water heat - ARFEC3500 W (IP20)
Item
number
Type Output*
5
[kW]
Airow*
1
[m
3
/h]
∆t
*4,5
[°C]
Water
volume
[l]
Sound
power*
2
[dB(A)]
Sound
pressure*
3
[dB(A)]
Motor
[W]
Amperage
motor
[A]
Weight
[kg]
190546 ARFEC3510W 8,3 1000/1900 16/13 1,3 75 43/59 340 2,3 36
190550 ARFEC3515W 12 1500/2800 16/13 2,1 76 43/60 510 3,2 49
190554 ARFEC3520W 17 2100/3700 17/14 2,9 77 45/61 670 4,2 63
2 Water heat - ARFEC3500 WLL (IP20)
Item
number
Type Output*
6
[kW]
Airow*
1
[m
3
/h]
∆t
*4,6
[°C]
Water
volume
[l]
Sound
power*
2
[dB(A)]
Sound
pressure*
3
[dB(A)]
Motor
[W]
Amperage
motor
[A]
Weight
[kg]
190547 ARFEC3510WLL 8,0 1000/1900 14/12 2,6 75 43/59 340 2,3 39
190551 ARFEC3515WLL 12 1500/2800 15/13 4,2 76 43/60 510 3,2 52
190555 ARFEC3520WLL 16 2100/3700 15/13 5,8 77 45/61 680 4,2 70
Содержание
- Arden 3500 1
- Arden 3500 2
- Arden 3500 3
- Arden 3500 4
- Mounting 4
- Arden 3500 5
- Dn20 3 4 inside thread 5
- Fig 3 snap fixings 5
- Fig 4 pc board fc is integrated within the air curtain at delivery 5
- Fig 5 the water coil is connected inside the unit through holes which are made during installation on the top or the side of the unit possible places are marked with punch marks 5
- Water connections 5
- Accessories 6
- Arden 3500 6
- Dtv200s 6
- Pa34cb pa34tr pa34vd fh1020 ar35xtt 6
- See separate manual 6
- Valve systems 6
- Vpfc15lf dn15 0 012 0 068 6
- Vpfc15nf dn15 0 024 0 13 6
- Vpfc20 dn20 0 058 0 32 6
- Vpfc25 dn25 0 10 0 60 6
- Vpfc32 dn32 0 22 1 03 6
- Accessories 7
- Arden 3500 7
- Control systems 7
- Fcbc05 10 25 fcsc10 25 7
- Fcbc05 5 m 7
- Fcbc10 10 m 7
- Fcbc25 25 m 7
- Fcda fc direct fcsa fc smart 7
- Fcdc fcwta 7
- Fcpa fc pro fcba fc building 7
- Fcsc10 10 m 7
- Fcsc25 25 m 7
- Fctxrf 7
- Fctxrf for fc smart fc pro 7
- Fcwta for water heated units 7
- See separate manual for fc 7
- The air curtain must be supplemented with a control system 7
- Arden 3500 8
- Arfec3500 a 8
- Wiring diagrams for control system in the fc manual 8
- Arden 3500 9
- Arfec3510 3515 e 9
- Wiring diagrams for control system in the fc manual 9
- Arden 3500 10
- Arfec3520 e 10
- Wiring diagrams for control system in the fc manual 10
- Arden 3500 11
- Arfec3500 w 11
- Fcbasepcb rea 11
- N l3 l2 l1 11
- Wiring diagrams for control system in the fc manual 11
- Ambient no heat arfec3500 a ip20 12
- Applicable at water temperature 40 30 c air temperature in 18 c 12
- Applicable at water temperature 60 40 c air temperature in 18 c 12
- Arden 3500 12
- Conditions distance to the unit 5 metres directional factor 2 equivalent absorption area 200 m² at low high airflow 2 10v 12
- Electrical heat arfec3500 e ip20 12
- Low high airflow 2 10v 12
- Measurements according to iso 27327 2 2014 installation type e 12
- See www frico net for additional calculations 12
- Sound power 12
- Sound pressure 12
- T temperature rise of passing air at maximum heat output and low high airflow 2 10v 12
- Technical specifications 12
- Water heat arfec3500 w ip20 12
- Water heat arfec3500 wll ip20 12
- Arden 3500 13
- Mонтаж 13
- Инструкция по монтажу и эксплуатации 13
- Назначение и область применения 13
- Назначение и принцип действия 13
- Общие положения 13
- Электроподключение 13
- Arden 3500 14
- Запуск e 14
- Подключение теплообменника w 14
- Arden 3500 15
- Настройка воздушного потока 15
- Обслуживание 15
- Основные настройки скорости потока 15
- Перегрев 15
- Регулирование температуры 15
- Сервис обслуживание и ремонт 15
- Фильтр w 15
- Arden 3500 16
- Возможные неисправности 16
- Замена блока электронагрева e 16
- Замена вентиляторов 16
- Замена встроенной управляющей платы 16
- Замена теплообменника w 16
- Предохранительное выключение 16
- Слив теплообменника w 16
- Arden 3500 17
- Безопасность 17
- Заводская упаковка 17
- Устройство защитного отключения узо e 17
- Утилизация прибора по завершении срока его полезной эксплуатации 17
- Arden 3500 18
- Перевод текста для страниц с рисунками 18
- Технические характеристики 18
Похожие устройства
- Systemair ARFEC3510WLL Инструкция по эксплуатации
- Systemair ARFEC3515A Инструкция по эксплуатации
- Systemair ARFEC3515E14 Инструкция по эксплуатации
- Systemair ARFEC3515W Инструкция по эксплуатации
- Systemair ARFEC3515WLL Инструкция по эксплуатации
- Systemair ARFEC3520A Инструкция по эксплуатации
- Systemair ARFEC3520E18 Инструкция по эксплуатации
- Systemair ARFEC3520W Инструкция по эксплуатации
- Systemair ARFEC3520WLL Инструкция по эксплуатации
- Systemair SIFEC10A-H Инструкция по эксплуатации
- Systemair SIFEC10E08-H Инструкция по эксплуатации
- Systemair SIFEC10WH-H Инструкция по эксплуатации
- Systemair SIFEC10WL-H Инструкция по эксплуатации
- Systemair SIFEC15A-H Инструкция по эксплуатации
- Systemair SIFEC15E12-H Инструкция по эксплуатации
- Systemair SIFEC15WH-H Инструкция по эксплуатации
- Systemair SIFEC15WL-H Инструкция по эксплуатации
- Systemair SIFEC20A-H Инструкция по эксплуатации
- Systemair SIFEC20A-V Инструкция по эксплуатации
- Systemair SIFEC20E16-V Инструкция по эксплуатации