Planet VIP-161W [45/72] Account setting
![Planet VIP-161W [45/72] Account setting](/views2/1071507/page45/bg2d.png)
45
TCP
TCP guarantees delivery of data and also guarantees that packets will be
delivered in the same order in which they were sent
SIP Time Interval
SIP time interval in milliseconds. The default setting is 500 m-sec
Timeout for Invite
INVITE message timeout value. Assigns a value 1 to 100, default setting
is 12 seconds. It denotes if an INVITE request was sent, and a response
is not received from the remote site within the allotted time. The present
request will be dropped and a new connection request will be initiated
Timeout for Ring Back
Timeout value for dropping a call after receiving 180 responses. Ring
back is an intermittent audio tone that a caller in a telephone system
hears after dialing a number, when the distant end of the circuit is
receiving a ringing signal. It can be generated by the servicing switch of
either the called party or the calling party. It is not generated by the called
instrument. The default setting is 180 seconds
Timeout for Release
BYE message timeout value. Assigns a time interval 1 to 4, default setting
is 4 seconds
Registration Retry count
Assigns a value 1 to 65535, To set the retry count for keepalive
retransmission, use the retry keepalive command in SIP user agent
configuration mode. To restore the retry count to the default value for
keepalive retransmission, use the no form of this command
SIP User Agent name
If specified, is the user-agent name to be used in a REGISTER request. If
not specified, the value in “SIP User Agent Name” will be used for
REGISTER request also. Default value is VOIP_Agent_001
Account Setting
There are two ports can be setup for SIP account.
Phone Number
Assigns Phone number for the first port, maximum 15 digits. Do not contain
any special characters or spaces. E.g. if you want to enter the number
+886 2 1234-5678, then it should be 886212345678
Display Name
This text message will be sent between the callee and caller and will show
on LCD panel for general using
Authentication User Name
User name for authentication. Maximum 36 characters
Authentication Password
User password for authentication. Maximum 24 characters
Содержание
- User s manual 1
- Vip 161w vip161sw 1
- Wireless analog telephone adapter 1
- Ce mark warning 2
- Copyright 2
- Disclaimer 2
- Trademarks 2
- Weee warning 2
- Chapter 1 4
- Chapter 2 11 4
- Chapter 3 9 4
- Configuring netowrk setting for your wi fi ata 9 4
- Overview 4
- Package content 4
- Physical details 4
- Physical installation requirement 1 4
- Chapter 4 3 5
- Information 9 5
- Management 1 5
- Sip configuration 3 5
- Voip setting 8 5
- Appendix a voice communication samples 8 6
- Appendix b frequently asked questions list 1 6
- Appendix c vip 161w vip 161sw specifications 2 6
- Chapter 1 7
- Introduction 7
- Overview 7
- Package content 8
- Product features 8
- Voip featires 8
- Physical details 9
- Led display 10
- Chapter 2 11
- Hardware installation 11
- Physical installation requirement 11
- Port description 11
- Preparations installation 11
- Administration interface 12
- Connecting to a pc 12
- Installation 12
- Web configuration access 12
- Operation mode 13
- Wizard setup 13
- Ap client mode 14
- Ap mode 14
- Wisp ap mode 14
- Ap setting 15
- Internet setting setup 15
- Wan setting 15
- Ap client mode 16
- Wisp ap mode 16
- Lan ip setting 17
- Nat setting 17
- Configure the numbering with phone line ports 18
- Finishing the wizard setup 18
- Voip call setup 18
- Chapter 3 19
- Configuring netowrk setting for your wi fi ata 19
- Network service configurations 19
- Wan setting lan setting 19
- Dhcp dynamic host configuration protocol 20
- Pppoe point to point protocol over ethernet 20
- Static ip 20
- Host name 21
- Mtu and mru 21
- Wan port mac 21
- Dns proxy 22
- Dns server 22
- Lan setting 22
- Ping from wan 22
- Ap mode 23
- Wlan setting 23
- Wlan settings 23
- Ap client only mode 25
- Wisp ap mode 27
- Access policy 29
- Access policy for ap and ap ap client mode only 29
- Dhcp server setting 30
- Static router 31
- Nat for ap ap client wisp ap mode 33
- Nat setting 33
- Virtual server settin 34
- Virtual server setting for ap mode 34
- Port trigger 35
- Packet filter 36
- Url filter 37
- Security for ap wisp ap mode 38
- Upnp for ap wisp ap mode 39
- Ddns for ap wisp ap mode 40
- Snmp for ap wisp ap mode 41
- Qos vlan 42
- Basic setting 43
- Chapter 4 43
- Sip configuration 43
- Wireless telephone adapter configurations 43
- Account setting 45
- Server setting 46
- Nat traversal 48
- Voice setting 48
- Voip setting 48
- Gain control level 49
- Dtmf method 50
- Rtp real time transport protocol 50
- Call service 51
- Call waiting 51
- Call forward option 52
- Call transfer option 52
- Fxs port setting 53
- Fax setting 55
- General dialing setting 55
- Phone book 55
- Dialing plan outgoing mode 56
- Call screen 58
- Qos setting 58
- Information 59
- System information 59
- Administrator account 61
- Line status 61
- Management 61
- Date time 62
- Ping test 63
- Factory default 64
- Firmware update 64
- Save restore 64
- Auto provision 65
- Enable or disable the auto provisioning feature if enabled wata will try to download the configuration 65
- Execution time default 1 hour 1 to 10 hours wata will try to download the configuration files from 65
- Files from the provisioning serve 65
- Provision server provision server default is empty 65
- The provisioning server 65
- Check network alive 66
- Save logout 66
- Save configuration logout 67
- Save configuration reboot 67
- Save configurations 67
- Appendix a voice communication samples 68
- Wata a 172 6 68
- Wata a 172 6 wata b 172 6 68
- Wata b 172 6 68
- Make a three way conference call 70
- Appendix b frequently asked questions list 71
- Appendix c vip 161w vip 161sw specifications 72
Похожие устройства
- Ariston WDG 862 Инструкция по эксплуатации
- Ariston WDD 8640B Инструкция по эксплуатации
- Planet VIP-193 Инструкция по эксплуатации
- Belkin F8N744cwC01 Инструкция по эксплуатации
- Planet VIP-1680 Инструкция по эксплуатации
- Ariston ARMXXL 1297 Инструкция по эксплуатации
- Belkin F8Z689cw Инструкция по эксплуатации
- Planet VIP-1680FS Инструкция по эксплуатации
- Ariston ARMXXD 1297 Инструкция по эксплуатации
- Ariston ARMXXD 1097 Инструкция по эксплуатации
- Planet VIP-2100 Инструкция по эксплуатации
- Ozaki IC838 Bl Инструкция по эксплуатации
- Planet VIP-2400 Инструкция по эксплуатации
- Ariston AQM9D 497 U Инструкция по эксплуатации
- Ariston WMD 842 B Инструкция по эксплуатации
- Planet VIP-281 Инструкция по эксплуатации
- Ariston WMSF 605B Инструкция по эксплуатации
- Planet VIP-281GS Инструкция по эксплуатации
- Planet VIP-480 Инструкция по эксплуатации
- Ariston MVSB 7105 S Инструкция по эксплуатации