8-4 FAN OPERATION IS POSSIBLE, BUT
COOLING AND HEATING DO NOT
WORK
• Immediately after the power is turned on.
The micro computer is getting ready to operate.
Wait 10 minutes.
8-5 THE FAN STRENGTH DOES NOT COR-
RESPOND TO THE SETTING
• The fan speed does not change even if the fan
speed control button is pressed.
During heating operation, when the room temper-
ature reaches the set temperature, the outdoor
unit goes off and the indoor unit changes to whis-
per the fan speed.
This is to prevent cold air blowing directly on occu-
pants of the room.
The fan speed will not change even if the button is
pressed, when another indoor unit is in heating
operation.
8-6 THE FAN DIRECTION DOES NOT COR-
RESPOND TO THE SETTING
• The fan direction does not correspond to the
remote controller display.
The fan direction does not swing.
This is because the unit is being controlled by the
micro computer. Refer to “Adjusting the air flow
direction”.
8-7 WHITE MIST COMES OUT OF THE UNIT
Indoor unit
•
When humidity is high during cooling operation.
If the interior of indoor unit is extremely contami-
nated, the temperature distribution inside a room
becomes uneven. It is necessary to clean the inte-
rior of indoor unit. Ask your Daikin dealer for
details on cleaning the unit. This operation
requires a qualified service person.
• Immediately after the cooling operation stops
when the room temperature and humidity are
low.
This is because warm refrigerant gas flows back
into the indoor unit and generates steam.
Indoor unit, outdoor unit
• When the system is changed over to heating
operation after defrost operation.
Moisture generated by defrost becomes steam
and is exhausted.
8-8 NOISE OF AIR CONDITIONERS
Indoor unit
• A “zeen” sound is heard immediately after the
power supply is turned on.
The electronic expansion valve inside the indoor
unit starts working and makes the noise. Its vol-
ume will reduce in about 1 minute.
• A continuous low “shah” sound is heard when
the system is in cooling operation or at a stop.
When the drain pump (an optional accessory) is
in operation, this noise is heard.
•
A “pishi-pishi” squeaking sound is heard when
the system stops after heating operation.
Expansion and contraction of plastic parts caused
by temperature change make this noise.
• A low “sah”, “choro-choro” sound is heard
while the indoor unit is stopped.
When the other indoor unit is in operation, this
noise is heard. In order to prevent oil and refriger-
ant from remaining in the system, a small amount
of refrigerant is kept flowing.
Outdoor unit
• When the tone of operating noise changes.
This noise is caused by the change of frequency.
Indoor unit, outdoor unit
• A continuous low hissing sound is heard
when the system is in cooling or defrost oper-
ation.
This is the sound of refrigerant gas flowing
through both indoor and outdoor units.
• A hissing sound which is heard at the start or
immediately after stopping operation or
defrost operation.
This is the noise of refrigerant caused by flow stop
or flow change.
8-9 DUST COMES OUT OF THE UNIT
• When the unit is used after stopping for a long
time.
This is because dust has gotten into the unit.
8-10 THE UNITS CAN GIVE OFF ODOURS
• The unit can absorb the smell of rooms, furni-
ture, cigarettes, etc., and then emit it again.
01_EN_3P161360-3D.fm Page 13 Thursday, April 13, 2006 9:46 AM
Содержание
- Operation manual 1
- System air conditioner 1
- Contents 4
- Safety considerations 4
- Remote controller and cool heat selector name and function of each switch and display 6
- Remote controller and cool heat selector name and function of each switch and display refer to figure 2 and 3 6
- What to do before opera tion 6
- What to do before operation 6
- 1 cooling heating automatic and fan only operation refer to figure 4 and 7 8
- Operation procedure 8
- Operation range 8
- 2 program dry operation 9
- 3 adjusting the air flow direction refer to figure 6 10
- 4 programming start and stop of the system with timer refer to figure 9 10
- 5 setting the master remote con troller refer to figure 10 11
- 6 precautions for group con trol system or two remote con troller control system 11
- Optimum operation 11
- 1 at the beginning of the season 12
- 1 the system does not operate 12
- 2 at the end of the season 12
- 2 it stops sometimes 12
- 3 cool heat cannot be changed over 12
- Following symptoms are not air conditioner trou bles 12
- Following symptoms are not air conditioner troubles 12
- Seasonal maintenance 12
- 10 the units can give off odours 13
- 4 fan operation is possible but cooling and heating do not work 13
- 5 the fan strength does not cor respond to the setting 13
- 6 the fan direction does not cor respond to the setting 13
- 7 white mist comes out of the unit 13
- 8 noise of air conditioners 13
- 9 dust comes out of the unit 13
- 11 the outdoor unit fan does not rotate 14
- 12 the display shows 14
- 13 the compressor or fan in the outdoor unit does not stop 14
- 14 the inside of outdoor unit is warm even when the unit has stopped 14
- 15 it stops sometimes 14
- 16 hot air is emitted even though the unit is stopped 14
- 17 does not cool very well 14
- Trouble shooting 14
- P161360 3d em03a045d 16
Похожие устройства
- Daikin REYQ144MTJU Руководство по эксплуатации
- Daikin REYQ168MTJU Руководство по вводу в эксплуатацию
- Daikin REYQ192MTJU Руководство по вводу в эксплуатацию
- Daikin REYQ72MTJU Сервис мануал
- Daikin REYQ144MTJU Сервис мануал
- Daikin REYQ168MTJU Руководство по эксплуатации
- Daikin REYQ192MTJU Руководство по эксплуатации
- Daikin REYQ168MTJU Сервис мануал
- Daikin REYQ192MTJU Сервис мануал
- Daikin RXQ5M9W1B Спецификация
- Daikin RXQ8M9W1B Спецификация
- Daikin RXQ10M9W1B Спецификация
- Daikin RXQ5M9W1B Руководство по вводу в эксплуатацию
- Daikin RXQ8M9W1B Руководство по вводу в эксплуатацию
- Daikin RXQ10M9W1B Руководство по вводу в эксплуатацию
- Daikin RXQ5M9W1B Технические данные
- Daikin RXQ8M9W1B Технические данные
- Daikin RXQ10M9W1B Технические данные
- Daikin RXQ5M9W1B Инструкция по монтажу
- Daikin RXQ8M9W1B Инструкция по монтажу