Daikin RXQ5PAY1 [202/398] Symptom based troubleshooting 94 2 troubleshooting by remote controller 97

Daikin RXQ5PAY1 [202/398] Symptom based troubleshooting 94 2 troubleshooting by remote controller 97
Si34-804
Troubleshooting 191
Part 6
Troubleshooting
1. Symptom-based Troubleshooting .......................................................194
2. Troubleshooting by Remote Controller ...............................................197
2.1 The INSPECTION / TEST Button.........................................................197
2.2 Self-diagnosis by Wired Remote Controller .........................................198
2.3 Self-diagnosis by Wireless Remote Controller .....................................199
2.4 Operation of the Remote Controller’s Inspection /
Test Operation Button ..........................................................................202
2.5 Remote Controller Service Mode .........................................................203
2.6 Remote Controller Self-Diagnosis Function .........................................205
3. Troubleshooting by Indication on the Remote Controller ....................212
3.1 A0” Indoor Unit: Error of External Protection Device............................212
3.2
A1
” Indoor Unit: PC Board Defect ........................................................213
3.3
A3
” Indoor Unit: Malfunction of Drain Level Control System (S1L) ......214
3.4
A6
” Indoor Unit: Fan Motor (M1F) Lock, Overload...............................216
3.5
A7 Indoor Unit: Malfunction of Swing Flap Motor (M1S).....................220
3.6
A8
” Abnormal Power Supply Voltage...................................................222
3.7
A9
” Indoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E)........................................................223
3.8 AF
” Indoor Unit: Drain Level above Limit .............................................225
3.9
AJ
” Indoor Unit: Malfunction of Capacity Determination Device ..........226
3.10
C1
” Indoor Unit: Failure of Transmission
(Between Indoor unit PC Board and Fan PC Board)............................227
3.11
C4
” Indoor Unit: Malfunction of Thermistor (R2T) for
Heat Exchanger....................................................................................229
3.12 C5
” Indoor Unit: Malfunction of Thermistor (R3T) for
Gas Pipes.............................................................................................230
3.13 C6
” Indoor Unit: Failure of Combination
(Between Indoor unit PC Board and Fan PC Board)............................231
3.14
C9
” Indoor Unit: Malfunction of Thermistor (R1T) for
Suction Air ............................................................................................232
3.15 CC
” Indoor Unit: Malfunction of Humidity Sensor System ....................233
3.16
CJ
” Indoor Unit: Malfunction of Thermostat Sensor
in Remote Controller ............................................................................234
3.17 E1
” Outdoor Unit: PC Board Defect .....................................................235
3.18
E3
” Outdoor Unit: Actuation of High Pressure Switch..........................236
3.19
E4
” Outdoor Unit: Actuation of Low Pressure Sensor..........................238
3.20
E5
” Outdoor Unit: Inverter Compressor Motor Lock.............................240
3.21
E6
” Outdoor Unit: STD Compressor Motor Overcurrent/Lock..............242
3.22
E7
” Outdoor Unit: Malfunction of Outdoor Unit Fan Motor ...................243
3.23
E9
” Outdoor Unit: Malfunction of Moving Part of
Electronic Expansion Valve (Y1E, Y2E)...............................................246
3.24 F3
” Outdoor Unit: Abnormal Discharge Pipe Temperature..................248
3.25
F6
” Outdoor Unit: Refrigerant Overcharged.........................................249
3.26
H7
” Outdoor Unit: Abnormal Outdoor Fan Motor Signal ......................250

Содержание

Скачать