Daikin RQYQ16PY1 [6/20] First of all
![Daikin RQYQ18PY1 [6/20] First of all](/views2/1718490/page6/bg6.png)
1 English
RQYQ8PY1
RQYQ10PY1
RQYQ12PY1
RQYQ14PY1
RQYQ16PY1
RQYQ18PY1
RQYQ20PY1
RQYQ22PY1
RQYQ24PY1
RQYQ26PY1
RQYQ28PY1
RQYQ30PY1
RQYQ32PY1
RQYQ34PY1
RQYQ36PY1
RQYQ38PY1
RQYQ40PY1
RQYQ42PY1
RQYQ44PY1
RQYQ46PY1
RQYQ48PY1
VRV
III
System air conditioner
“Ve-upQ” Series
Installation
manual
CONTENTS
1. FIRST OF ALL ......................................................................... 1
1-1 Safety precautions .......................................................... 1
1-2 Special notice of product ................................................. 2
1-3 Disposal requirements ..................................................... 2
2. INTRODUCTION...................................................................... 2
2-1 Combination..................................................................... 2
2-2 Standard supplied accessories........................................ 3
2-3 Option accessory ............................................................. 3
2-4 Technical and Electrical specifications ............................ 3
2-5 Main components ............................................................ 3
2-6 Installation Process.......................................................... 3
3. SELECTION OF LOCATION ................................................... 3
4. INSPECTING AND HANDLING THE UNIT ............................. 4
5. PLACING THE UNIT................................................................ 4
6. REFRIGERANT PIPING .......................................................... 4
6-1 Selection of piping material and Refrigerant
branching kit .................................................................... 4
6-2
Protection against contamination when installing pipes
... 5
6-3 Pipe connection ............................................................... 5
6-4 Connecting the refrigerant piping..................................... 5
7. FIELD WIRING ........................................................................ 7
7-1 Power circuit, safety device, and cable requirements...... 7
7-2 Wiring Connection Example for Whole System ............... 7
7-3 Leading wire Procedure................................................... 7
7-4 Transmission Wiring Connection Procedure ................... 8
7-5 Power Wiring Connection Procedure............................... 8
7-6 Procedure for Wiring Inside Units .................................... 9
8. AIR TIGHT TEST AND VACUUM DRYING ............................. 9
8-1 Preparations .................................................................... 9
8-2 Air tight test and vacuum drying method ......................... 9
9. PIPE INSULATION ................................................................ 10
10. CHECKING OF DEVICE AND INSTALLATION
CONDITIONS ........................................................................ 10
11. ADDITIONAL REFRIGERANT CHARGE AND
CHECK OPERATION ............................................................ 10
11-1 Before working ............................................................... 10
11-2 Procedure of Adding Refrigerant charging and check
operation........................................................................ 12
12. ONSITE SETTINGS............................................................... 13
12-1 Onsite Settings With the Power Off ............................... 13
12-2 Onsite Settings With the Power On ............................... 13
13. TEST RUN ............................................................................. 13
13-1 Before test run ............................................................... 13
13-2 Test Run ........................................................................ 13
13-3 Checks After Test Run................................................... 13
14. CAUTION FOR REFRIGERANT LEAKS ............................... 13
1. FIRST OF ALL
• This document is an installation manual for the Daikin “Ve-upQ”
Series VRV Inverter. Before installing the unit, read this manual
thoroughly, and following the instructions contained in it. After
installation, do a test run to make sure the unit runs properly, and
then explain how to operate and take care of the unit to the cus-
tomer, using the operation manual.
• Lastly, make sure the customer keeps this manual, along with the
operation manual, in a safe place.
•
This manual does not describe how to install the indoor unit.
Refer to the installation manual included with the indoor unit for that.
1-1 Safety precautions
Please read these “Safety precautions” carefully before installing air
conditioning unit and be sure to install it correctly.
After completing installation, conduct a trial operation to check for
faults and explain to the customer how to operate the air conditioner
and take care of it with the aid of the operation manual. Ask the cus-
tomer to store the installation manual along with the operation man-
ual for future reference.
This air conditioner comes under the term “appliances not
accessible to the general public”.
Meaning of WARNING and CAUTION notices
WARNING
..... Failure to follow these instructions properly may
result in personal injury or loss of life.
CAUTION
...... Failure to observe these instructions properly
may result in property damage or personal injury,
which may be serious depending on the circum-
stances.
WARNING
• Ask your dealer or qualified personnel to carry out installation
work.
Do not attempt to install the air conditioner yourself. Improper
installation may result in water leakage, electric shocks or fire.
• Install the air conditioner in accordance with the instructions in
this installation manual.
Improper installation may result in water leakage, electric shocks
or fire.
• When installing the unit in a small room, take measures against to
keep refrigerant concentration from exceeding allowable safety
limits in the event of refrigerant leakage.
Contact the place of purchase for more information. Excessive
refrigerant in a closed ambient can lead to oxygen deficiency.
• Be sure to use only the specified accessories and parts for instal-
lation work.
Failure to use the specified parts may result in the unit falling,
water leakage, electric shocks or fire.
• Install the air conditioner on a foundation strong enough to with-
stand the weight of the unit.
A foundation of insufficient strength may result in the equipment
falling and causing injury.
• Carry out the specified installation work after taking into account
strong winds, typhoons or earthquakes.
Failure to do so during installation work may result in the unit fall-
ing and causing accidents.
•
Make sure that a separate power supply circuit is provided for this
unit and that all electrical work is carried out by qualified personnel
according to local laws and regulations and this installation manual.
An insufficient power supply capacity or improper electrical con-
struction may lead to electric shocks or fire.
• Make sure that all wiring is secured, the specified wires are used,
and that there is no strain on the terminal connections or wires.
Improper connections or securing of wires may result in abnormal
heat build-up or fire.
• When wiring the power supply and connecting the remote control-
ler wiring and transmission wiring, position the wires so that the
EL.COMPO.BOX lid can be securely fastened.
Improper positioning of the EL.COMPO.BOX lid may result in
electric shocks, fire or the terminals overheating.
• If refrigerant gas leaks during installation, ventilate the area
immediately.
Toxic gas may be produced if the refrigerant comes into contact
with fire.
• After completing installation, check for refrigerant gas leakage.
Toxic gas may be produced if the refrigerant gas leaks into the
room and comes into contact with a source of fire, such as a fan
heater, stove or cooker.
• Do not directly touch refrigerant that has leaked from refrigerant
pipes or other areas, as there is a danger of frostbite.
• Be sure to switch off the unit before touching any electrical parts.
• Do not allow children to climb on the outdoor unit and avoid plac-
ing objects on the unit.
Injury may result if the unit becomes loose and falls.
• Be sure to earth the air conditioner.
Do not earth the unit to a utility pipe, lightning conductor or
telephone earth lead. Imperfect earthing may result in
electric shocks or fire.
A high surge current from lightning or other sources may cause
damage to the air conditioner.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric
shocks or fire.
CAUTION
• While following the instructions in this installation manual,
install drain piping to ensure proper drainage and insulate pip-
ing to prevent condensation.
Improper drain piping may result in indoor water leakage and
property damage.
Содержание
- Installation manual 1 1
- System air conditioner 1
- Ve upq series 1
- Figure 1 3
- Figure 10 figure 11 figure 12 figure 13 3
- Figure 14 3
- Figure 15 3
- Figure 2 3
- Figure 3 3
- Figure 4 3
- Figure 5 3
- Figure 6 3
- Figure 7 3
- Figure 8 3
- Figure 9 3
- Figure 16 4
- Figure 17 4
- Figure 18 4
- Figure 19 figure 20 4
- Figure 21 4
- Figure 22 4
- Figure 23 4
- Figure 24 4
- Figure 25 4
- Figure 26 4
- Figure 27 5
- Figure 28 5
- Figure 29 figure 30 5
- Figure 31 figure 32 5
- Figure 33 5
- Figure 34 5
- 1 safety precautions 6
- Contents 6
- English 6
- First of all 6
- Installation manual 6
- 1 combination 7
- 2 special notice of product 7
- 3 disposal requirements 7
- English 2 7
- Introduction 7
- 2 standard supplied accessories 8
- 3 option accessory 8
- 4 technical and electrical specifications 8
- 5 main components 8
- 6 installation process 8
- English 8
- Selection of location 8
- 1 selection of piping material and refrigerant branching kit 9
- English 4 9
- Inspecting and handling the unit 9
- Placing the unit 9
- Refrigerant piping 9
- 2 protection against contamination when installing pipes 10
- 3 pipe connection 10
- 4 connecting the refrigerant piping 10
- A b 25 10
- Cutting location 10
- English 10
- Gas side accessory pipe 2 10
- Gas side piping field supply 10
- Change as shown in the figure below rising height 200 mm or more 11
- Change to pattern 1 or pattern 2 11
- English 6 11
- Front connections 11
- If 2 m or more 11
- If less than 2m 11
- Less than 2m 11
- M or more 11
- Oil remains in the stopping outdoor unit 11
- Outdoor unit gas pipe 11
- Pattern 1 11
- Pattern 2 11
- Prohibited pattern 11
- To indoor unit 11
- Unit a 11
- Unit b 11
- 1 power circuit safety device and cable requirements 12
- 2 wiring connection example for whole system 12
- 3 leading wire procedure 12
- English 12
- Field wiring 12
- 4 transmission wiring connection procedure 13
- 5 power wiring connection procedure 13
- English 8 13
- Power wire crimp style terminal 13
- 1 preparations 14
- 2 air tight test and vacuum drying method 14
- 6 procedure for wiring inside units 14
- Air tight test and vacuum dry ing 14
- Air tight test and vacuum drying 14
- Crimp style terminal 14
- Cup washer 14
- Cut out section 14
- English 14
- R410a label 14
- Resin hook 14
- Terminal block crip style terminal wire narrow wire thick 14
- 1 before working 15
- Additional refrigerant charge and check operation 15
- Checking of device and instal lation conditions 15
- Checking of device and installation conditions 15
- English 10 15
- Pipe insulation 15
- 2 procedure of adding refrigerant charging and check operation 17
- English 12 17
- 1 before test run 18
- 1 onsite settings with the power off 18
- 2 onsite settings with the power on 18
- 2 test run 18
- 3 checks after test run 18
- Caution for refrigerant leaks 18
- English 18
- Onsite settings 18
- Test run 18
- English 14 19
Похожие устройства
- Daikin RQYQ16PY1 Инструкция по эксплуатации
- Daikin RQYQ16PY1 Сервис мануал
- Daikin RQYQ18PY1 Спецификация
- Daikin RQYQ18PY1 Руководство по вводу в эксплуатацию
- Daikin RQYQ18PY1 Инструкция по монтажу
- Daikin RQYQ18PY1 Инструкция по эксплуатации
- Daikin RQYQ18PY1 Сервис мануал
- Daikin RQYQ20PY1 Спецификация
- Daikin RQYQ20PY1 Руководство по вводу в эксплуатацию
- Daikin RQYQ20PY1 Инструкция по монтажу
- Daikin RQYQ20PY1 Инструкция по эксплуатации
- Daikin RQYQ20PY1 Сервис мануал
- Daikin RQYQ22PY1 Спецификация
- Daikin RQYQ22PY1 Руководство по вводу в эксплуатацию
- Daikin RQYQ22PY1 Сервис мануал
- Daikin RQYQ22PY1 Инструкция по монтажу
- Daikin RQYQ22PY1 Инструкция по эксплуатации
- SilverStone AR03 Инструкция по эксплуатации
- SilverStone AR03 Документация
- SilverStone SST-AR03 Инструкция по эксплуатации
Скачать
Случайные обсуждения