SilverStone SST-AD120-T [5/8] Protection characteristics
![SilverStone AD120-T [5/8] Protection characteristics](/views2/1719660/page5/bg5.png)
02
3. Protection Characteristics:
ITEM
2.6 Hold Up Time:
2.7 Rise Time:
2.8 Dynamic Load Change:
2.9 Overshoot:
CONDITION
At 100Vac or 240Vac / 6.32A load,
output voltage shall remain regulation
At 100Vac / 6.32A load, DC output
rise time from 5% to 95% of Vo
(1) Output load step is:
【1】0 % ~ 50 %
【2】50 % ~ 100 %
(2)S/R=0.5A/us
(3)Frequency is 100Hz and 1KHz
100Vac, 240Vac / 0A and 6.32A load
SPECIFICATION
≧ 10ms
≦ 50ms
19V ± 10%
19V ± 10%
ITEM
3.1 Short Circuit Protection:
3.2 Over Voltage Protection:
3.3 Over Power Protection:
3.4 Over Temperature Protection:
CONDITION
When an internal fault occurs, or an external
fault is applied to the power supply, such
that an overload or short circuit is applied to
the output, the power supply shall shut down
and enter auto-recovery mode.
The adapter will enter into shut down that
means no output while over voltage
happened at output terminal that caused by
internal fault, the output trip voltage shall
not exceed 29 volts. That will be return to
normal state by AC reset.
When an internal fault occurs, or an external
fault is applied to the power supply, such
that an overload or short circuit is applied to
the output, the power supply shall shut down
and enter auto-recovery mode.
The power supply will enter into shut down
while the abnormal thermal rise occurs.
That will be return to normal state by
AC reset.
SPECIFICATION
Shutdown and no damage
Shutdown and no damage
Shutdown and no damage
No fire, no smoke
Содержание
- Ad120 t 1
- Adapter series 1
- Manual ad120 t p235 v2 cover 1
- W ac adapter for laptops intel small form factor pcs 1
- 空白頁面 2
- Installation 3
- Manual ad120 t p235 目錄 v2 3
- Adapter series ad120 t 4
- Input characteristics 4
- Manual ad120 t p235 p1 v2 4
- Output characteristics 4
- Specification 4
- W 19vdc ac dc adapter 4
- Manual ad120 t p235 p2 v2 5
- Protection characteristics 5
- Environmental characteristics 6
- Manual ad120 t p235 p3 v2 6
- 1 this device may not cause harmful interference and 2 this device must accept any interference receivcd including interference that may cause undesired operation 7
- Manual ad120 t p235 p4 v2 7
- This device complies with part 15 of the fcc rules operation is subject to the following two conditions 7
Похожие устройства
- SilverStone SST-AD120-T Брошюра
- SilverStone SST-AD120-T инструкция по установке
- SilverStone NJ600 Инструкция по эксплуатации
- SilverStone NJ600 инструкция по установке
- SilverStone NJ600 Брошюра
- SilverStone SST-NJ600 Инструкция по эксплуатации
- SilverStone SST-NJ600 инструкция по установке
- SilverStone SST-NJ600 Брошюра
- SilverStone NJ700 Инструкция по эксплуатации
- SilverStone NJ700 Брошюра
- SilverStone NJ700 инструкция по установке
- SilverStone SST-NJ700 Инструкция по эксплуатации
- SilverStone SST-NJ700 Брошюра
- SilverStone SST-NJ700 инструкция по установке
- Daikin ALB02RBMNADBT00 Руководство по эксплуатации
- Daikin ALB03RBMNADBT00 Руководство по эксплуатации
- Daikin ALB04RBMNADBT00 Руководство по эксплуатации
- Daikin ALB05RBMNADBT00 Руководство по эксплуатации
- Daikin ALB06RBMNADBT00 Руководство по эксплуатации
- Daikin ALB07RBMNADBT00 Руководство по эксплуатации