SilverStone SST-AD120-T [5/8] Protection characteristics

SilverStone AD120-T [5/8] Protection characteristics
02
3. Protection Characteristics:
ITEM
2.6 Hold Up Time:
2.7 Rise Time:
2.8 Dynamic Load Change:
2.9 Overshoot:
CONDITION
At 100Vac or 240Vac / 6.32A load,
output voltage shall remain regulation
At 100Vac / 6.32A load, DC output
rise time from 5% to 95% of Vo
1 Output load step is
  【10 % ~ 50 %
  【250 % ~ 100 %
2S/R=0.5A/us
3Frequency is 100Hz and 1KHz
100Vac, 240Vac / 0A and 6.32A load
SPECIFICATION
10ms
50ms
19V ± 10%
19V ± 10%
ITEM
3.1 Short Circuit Protection:
3.2 Over Voltage Protection:
3.3 Over Power Protection:
3.4 Over Temperature Protection:
CONDITION
When an internal fault occurs, or an external
fault is applied to the power supply, such
that an overload or short circuit is applied to
the output, the power supply shall shut down
and enter auto-recovery mode.
The adapter will enter into shut down that
means no output while over voltage
happened at output terminal that caused by
internal fault, the output trip voltage shall
not exceed 29 volts. That will be return to
normal state by AC reset.
When an internal fault occurs, or an external
fault is applied to the power supply, such
that an overload or short circuit is applied to
the output, the power supply shall shut down
and enter auto-recovery mode.
The power supply will enter into shut down
while the abnormal thermal rise occurs.
That will be return to normal state by
AC reset.
SPECIFICATION
Shutdown and no damage
Shutdown and no damage
Shutdown and no damage
No fire, no smoke