SilverStone SST-AD120-T [6/8] Environmental characteristics

SilverStone AD120-T [6/8] Environmental characteristics
03
4. Environmental Characteristics:
ITEM
4.1 Electric Fast Transients:
 Refer to IEC61000-4-4
4.2 Lightning Surge:
  Refer to IEC61000-4-5
4.3 Electron Static Discharge:
(Refer to IEC61000-4-2 Energy
Storage Capacitor
150pF; Discharge Resistor
330)
4.4 Cooling:
4.5 EMI: Adapter comply with
the following
national standards:
EMI Conducted Emission
EMI Radiated Emission
4.6 Safety conforming:
4.6.1 Energy-related ProductsErP
Department of EnergyDOE
4.7 Leakage Current:
4.8 Dielectric Strength: (Hi-Pot)
CONDITION
Impulse: ± 1kV applied to L,N
1kV applied differential mode
2kV applied common mode
Air Discharge: +/-15 KV
Contact Discharge: +/- 8 KV
Natural air cooling
1.Full Load
2. The power supply with internal filter
can meet.
--
--
264Vac / 50Hz
Between AC input and secondary
applied AC 1.5KV / test time 1 minute /
cut off current shall be less than 10mA
SPECIFICATION
Normal operation shall be continued
Normal operation shall be continued
Normal operation shall be continued
--
FCC PART 15J CLASS B
CISPR22 EN55022 CLASS B
VCCI LEVEL Π
Regulated by customer
Comply with ErP standard
Comply with DOE standard
0.25mA
 
--