SilverStone OP850-P [2/12] Specification
![SilverStone SST-OP750 [2/12] Specification](/views2/1720109/page2/bg2.png)
01
Parameter
Voltage (115V)
Voltage (230V)
Frequency
Norminal
100-120Vac
200-240Vac
50 / 60 Hz
Maximum
132 Vac
264Vac
63 Hz
Max. Current
12A
6A
Minimum
90 Vac
180 Vac
47 Hz
SPECIFICATION
SilverStone OLYMPIA OP750
Switching Power Supply
Active PFC
PS/2 750W
1. General
This is the specification of Model OP750; it is intended to describe the functions and
performance of the subject power supply. This PS/2 750 watts switching power supply
with Active PFC (Power Factor Correction) capability, meets EN61000-3-2 and equips
Full Range Input features.
2. AC Input Specifications
2-1. AC Input Voltage, Frequency and Current ( Rating: 100V-240Vac, 47-63Hz,
12-6A )
The power supply must operate within all specified limits over the input voltage
range in Table 1.
Harmonics distortion of up to 10% THD must not cause the power supply to go out
of specified limits.
Table 1 - AC Input Voltage and Frequency
2-2. AC Inrush Current
The power supply must meets inrush requirements of any rated AC voltage, during
turn on at any phase of voltage, during a single cycle AC dropout condition, during
repetitive On/Off cycling of AC, and over the specified temperature range. The peak
inrush current shall be less than the rating of its critical components (including input
fuse, bulk rectifiers, and surge limiting device).
2-3. Input Power Factor Correction ( Active PFC)
The power factor at full load shall be 0.99 at nominal input voltage.
2-4. Input Current Harmonics
When the power supply is operated in 90-264Vac of Sec. 2.1, the input harmonic
current drawn on the power line shall not exceed the limits set by EN61000-3-2
class "D" standards. The power supply shall incorporate universal power input with
active power factor correction.
2-5. AC Line Dropout
An AC line dropout of 17mS or less shall not cause any tripping of control signals or
protection circuits. If the AC dropout lasts longer than 17mS the power supply
should recover and meet all turn on requirements. The power supply shall meet the
regulation requirement over all rated AC voltages, frequencies, and output loading
conditions. Any dropout of the AC line shall not cause damage to the power supply.
An AC line dropout is defined as a drop in AC line to 0VAC at any phase of the AC
line for any length of time.
<
-
Содержание
- Elevated power without limits 1
- Olympia 1
- Op750 manual 01 1
- 1 ac input voltage frequency and current rating 100v 240vac 47 63hz 12 6a 2
- 2 ac inrush current 2
- 3 input power factor correction active pfc 2
- 4 input current harmonics 2
- 5 ac line dropout 2
- Ac input specifications 2
- General 2
- Op750 manual 02 2
- Silverstone olympia op750 switching power supply active pfc ps 2 750w 2
- Specification 2
- 1 output current loading 3
- 2 dc voltage regulation ripple and noise 3
- 3 timing requirements 3
- Dc output specification 3
- Olympia op750 olympia op750 3
- Op750 manual 03 3
- Ripple and noise shall be measured using the following methods 3
- Table 5 output loads range 3
- Table 7 regulation ripple and noise 3
- Op750 manual 04 4
- Table 10 output voltage 4
- 4 remote on off control pson 5
- 5 efficiency 5
- 6 5vsb standby 5
- Ac input 5
- Ac off ac on 5
- Olympia op750 olympia op750 5
- Op750 manual 05 5
- Table 13 pwok signal characteristic 5
- The 5vsb output is always on 5v standby when ac power is applied and power switch is turned on the 5vsb line is capable of delivering at a maximum of 3a for pc board circuit to operate 5
- The efficiency is specified at 50 and 20 loading conditions to help reduce system power consumption at typical system loading conditions 5
- The pson signal is required to remotely turn on off the power supply pson is an active low signal that turns on the 5v 3 v 12v and 12v power rails when this signal is not pulled low by the system or left open the outputs except the 5vsb and v bias turn off this signal is pulled to a standby voltage by a pull up resistor internal to the power supply 5
- 1 over current protection 6
- 1 temperature 6
- 2 over voltage protection 6
- 3 short circuit protection 6
- Environmental requirements 6
- Non operating temperature range 40 70 40 158 6
- Op750 manual 06 6
- Operating temperature range 0 50 32 122 6
- Protection 6
- Protection circuits inside the power supply shall cause only the power supply s main outputs to shutdown if the power supply latches off due to a protection circuit tripping either a ac cycle off for 15 sec or pson cycle high for 1 sec must be able to restart the power supply 6
- The power supply shall shut down in a latch off mode when the output voltage exceeds the over voltagelimit shown in table 4 6
- The power supply shall shut down in a latch off mode when the output voltage is short circuit 6
- This power supply shall have current limit to prevent the 5v 3 v and 12v outputs from exceeding the values shown in table 14 the current limit shall not trip under maximum continuous load or peak loading as described in table 5 the power supply shall latch off if the current exceeds the limit the latch shall be cleared by toggling the pson signal or by cycling the ac power the power supply shall not be damaged from repeated power cycling in this condition the 12v and 5vsb outputs shall be shorted circuit protected so that no damage can occur to the power supply 6
- 1 mean time between failures mtbf 7
- 1 safety certification 7
- 2 ac input leakage current 7
- 2 humidity 7
- 2 warranty 7
- Agency requirements 7
- Input leakage current from line to ground will be less than 3 ma rms measurement will be made at 240 vac and 60hz 7
- Non operating humidity range 5 95 rh non condensing 7
- Olympia op750 olympia op750 7
- Op750 manual 07 7
- Operating humidity range 20 90 rh non condensing 7
- Reliability 7
- The mtbf of the power supply shall be calculated utilizing the part stress analysis method of mil217f or bell core rpp the calculated mtbf of the power supply shall be greater than 100 000 hours under the following conditions full rated load 120v ac input ground benign 25 7
- Three 3 years manufacture s warranty technical information in this specification is subject to change without notice the revision of specification will be marked on the cover 7
- 1 ac input connector 8
- 2 dc wire harness and connector requirements 8
- Connections 8
- Op750 manual 08 8
- P1 motherboard power connector connector housing 24 pin molex 5557 no 9 01 2240 or equivalent contact molex 5556t no 4476 1111 or equivalent 8
- The ac input connector shall be an iec 320 c 14 power inlet this inlet is rated for 15 a 250 vac 8
- 12v baseboard power connector connector housing 4 pin molex 5557 39 01 2040 or equivalent contact molex 5556t 39 00 0059 or equivalent 9
- Olympia op750 9
- Op750 manual 09 9
- P2 processor power connector connector housing 8 pin molex 5557 39 01 2080 or equivalent contact molex 5556t 39 00 0059 or equivalent 9
- Pin hdd cd rom drive power connectors connector housing 4 pin amp 1 480424 0 or molex 8981 04p or equivalent contact amp 61314 1 or equivalent 9
- Signal 9
- Yellow green stripe 9
- For workstation systems with high powered graphics cards an additional power connector to the baseboard may be needed this connector supplies additional 12v power for the higher power level graphics cards used in workstation applications connector housing 6 pin molex 45559 0002 or equivalent contacts molex 39 00 0207 or equivalent 10
- Op750 manual 10 10
- Orange 10
- Pci express 6 pin 10
- Pci express 8 pin 10
- Serial ata power connector 10
- Signal 10
- This is a required connector for systems with serial ata devices molex housing 675820000 or equivalent molex terminal 67510000 or equivalen 10
- Workstation power connector for high power graphics cards 10
- Yellow green stripe 10
- Op750 manual 11 11
- Op750 manual 12 12
Похожие устройства
- SilverStone OP850-P инструкция по установке
- SilverStone SST-OP850-P Инструкция по эксплуатации
- SilverStone SST-OP850-P инструкция по установке
- SilverStone ST1000-G Инструкция по эксплуатации
- SilverStone ST1000-G инструкция по установке
- SilverStone SST-ST1000-G Инструкция по эксплуатации
- SilverStone SST-ST1000-G инструкция по установке
- SilverStone ST1000-NV Инструкция по эксплуатации
- SilverStone ST1000-NV инструкция по установке
- SilverStone SST-ST1000-NV Инструкция по эксплуатации
- SilverStone SST-ST1000-NV инструкция по установке
- SilverStone ST1200 Инструкция по эксплуатации
- SilverStone ST1200 инструкция по установке
- SilverStone SST-ST1200 Инструкция по эксплуатации
- SilverStone SST-ST1200 инструкция по установке
- SilverStone ST1200-G Инструкция по эксплуатации
- SilverStone ST1200-G инструкция по установке
- SilverStone SST-ST1200-G Инструкция по эксплуатации
- SilverStone SST-ST1200-G инструкция по установке
- SilverStone ST30GF Инструкция по эксплуатации