SilverStone SST-ST40F [5/12] St40f manual p04 pdf
![SilverStone SST-ST40F [5/12] St40f manual p04 pdf](/views2/1720204/page5/bg5.png)
04
4.3 HOLD-UP TIME (@FULL LOAD)
115V / 60Hz : 17 mSec. Minimum.
230V / 50Hz : 17 mSec. Minimum.
4.4 OUTPUT RISE TIME
(10% TO 95% OF FINAL OUTPUT VALUE, @FULL LOAD)
115V-rms or 230V-rms + 3.3Vdc : 20ms Maximum
+ 5Vdc : 20ms Maximum
+ 12Vdc : 20ms Maximum
+ 5Vsb : 25ms Maximum
- 12Vdc : 20ms Maximum
The output voltage will remain within specification, in the event that the input power is removed or
interrupted, for the duration of one cycle of the input frequency. The interruption may occur at any
point in the AC voltage cycle. The power good signal shall remain high during this test.
4.2 LOAD CAPACITY SPECIFICATIONS
The cross regulation defined as follows, the voltage regulation limits DC include DC Output
ripple & noise.
LOAD
STM. +3.3V +5V
+12V1 DC +12V2 DC
-12V +5VSB
LHMMHH
0.5A 30A 9.7A 9.7A 0.5A 2A
FULL LOAD
HMMMHH
30A 10.6A 9.7A 9.7A 0.5A 2A
FULL LOAD
LLLLLL
0.5A 0.3 A 1A 1A 0A 0A
ALL MIN
HLLLLL
30A 3A 3A 3A 0A 0A
+3.3V MAX
other MIN
LHLLLL
0.5A 21A 1.5A 1.5A 0A 0A
+5V MAX
Other MIN
LLLLHL
0.5A 0.3A 1A 1A 0.5A 0A
-12V MAX
other MIN
LLLLLH
0.5A 0.3A 1A 1A 0A 2A
+5VSB MAX
other MIN
LLHHLL
2A 2A 14A 15A 0A 0A
+12V1&+12V2 MAX
Other MIN
Содержание
- Elevated performance at ease 1
- St40f manual cover pdf 1
- Strider 1
- General description and scope 2
- Reference documents 2
- Silverstone strider st40f atx12v 2 switching power supply with active pfc ps 2 400w 2
- Specification 2
- St40f manual p01 pdf 2
- Input electrical specifications 3
- St40f manual p02 pdf 3
- Output electrical requirements 4
- St40f manual p03 pdf 4
- 12v 5vsb 5
- All min 5
- Full load 5
- Hlllll 5
- Hold up time full load 115v 60hz 17 msec minimum 230v 50hz 17 msec minimum 5
- Lhllll 5
- Llhhll 5
- Llllhl 5
- Lllllh 5
- Llllll 5
- Load capacity specifications the cross regulation defined as follows the voltage regulation limits dc include dc output ripple noise 5
- Output rise time 10 to 95 of final output value full load 5
- St40f manual p04 pdf 5
- Stm 3 v 5v 5
- The output voltage will remain within specification in the event that the input power is removed or interrupted for the duration of one cycle of the input frequency the interruption may occur at any point in the ac voltage cycle the power good signal shall remain high during this test 5
- V rms or 230v rms 3 vdc 20ms maximum 5vdc 20ms maximum 12vdc 20ms maximum 5vsb 25ms maximum 12vdc 20ms maximum 5
- St40f manual p05 pdf 6
- Environmental requirements 7
- Fan noise requirements 7
- St40f manual p06 pdf 7
- Labelling 8
- St40f manual p07 pdf 8
- Pin definition 9
- St40f manual p08 pdf 9
- St40f manual p09 pdf 10
- St40f manual p10 pdf 11
- St40f manual buttom pdf 12
Похожие устройства
- SilverStone SST-ST40F инструкция по установке
- SilverStone ST40F-ES Инструкция по эксплуатации
- SilverStone ST40F-ES инструкция по установке
- SilverStone SST-ST40F-ES Инструкция по эксплуатации
- SilverStone SST-ST40F-ES инструкция по установке
- SilverStone ST40F-ESB (V1) Инструкция по эксплуатации
- SilverStone ST40F-ESB (V1) инструкция по установке
- SilverStone SST-ST40F-ESB (V1) Инструкция по эксплуатации
- SilverStone SST-ST40F-ESB (V1) инструкция по установке
- SilverStone ST40NF Инструкция по эксплуатации
- SilverStone ST40NF инструкция по установке
- SilverStone SST-ST40NF Инструкция по эксплуатации
- SilverStone SST-ST40NF инструкция по установке
- SilverStone ST42GF Инструкция по эксплуатации
- SilverStone ST42GF инструкция по установке
- SilverStone SST-ST42GF Инструкция по эксплуатации
- SilverStone SST-ST42GF инструкция по установке
- SilverStone ST45NF Инструкция по эксплуатации
- SilverStone ST45NF инструкция по установке
- SilverStone SST-ST45NF Инструкция по эксплуатации