SilverStone ST50F-230 [7/12] St50f 230 6

SilverStone SST-ST50F-230 [7/12] St50f 230 6
3.2 Short Circuit Protection
A short circuit placed to ground shall cause no damage or power supply shall be shutdown.
(The contact resistance is 0.05 ohm when the outputs short circuit.)
3.3 Protection Reset
When the power supply latches into shutdown condition due to a fault on an+5V,+3.3V,+12V1,+12V2
output( OVP, UVP,OCP ), the protection shall reset after the fault has been removed, use remote
on/off control or recycle the AC power again for a typical of 5 seconds.
3.4 Over
3.6 Over Current Power
shoot Protection
Any output overshoot at turn on shall be less than 15% of the normal output value
(with resistive load) as described in sec. 2.1.
At 230Vac input the power supply will shut down all DC output within 110% to 150% of full load.
3.5 Over
power Protection
4. ENVIRONMENT
4.1 Operation/Storage Temperature Range
Operation : 5 Cto 50
C (normal input)
Storage : -40 C to 70
C
4.2 Humidity (none condensing)
Operation : 20% to 85% RH (normal input)
Storage : 10% to 95% RH
DC output MAX
+12V1~2
15.5
Units
V
+5V
+3.3V 4.6
V
6.5
V
OUTPUT VOLTAGE
+5 V 45 A
Max over current limit
+12 V1
+12 V2
+3.3 V
27 A
37.5 A
27 A
Load
100%
80%
50
C
25
C
STRIDER SST-ST50F-230
06

Содержание

Скачать