SilverStone ST50F-230 [8/12] St50f 230 7

SilverStone ST50F-230 [8/12] St50f 230 7
6. EMI Requirements
7. Dielectric Voltage Withstand (HI-POT)
The power supply shall withstand for 3 seconds without breakdown the application of an
1800Vac-supply voltage applied between both input line and chassis (15mA AC Cutoff current).
Isolating transformers shall similarly withstand 4242Vdc applied between both primary and
secondary windings for a minimum of one minute.
8. PFC
Active Power Factor Correction, complies with EN 61000-3-2: 2000, Class D.
9. Electrostatic Discharge (ESD)
Comply with IEC 61000-4-2.
10. EFT/ Burst
Comply with IEC 61000-4-4
Comply with IEC 61000-4-5.
The power supply shall have a minimum mean time between failure greater than 100,000 hours at
continuous operation of 100% load and an ambient temperature of 25 C
1
11. Surge
Applying 230 Vac + 10% input voltage and maximum load (80%) for this product in 45 + 5 C chamber.
12. Burn-In
13. M.T.B.F.
A6-1.CE
5. Safety
5-1. TUV EN 60950-1
5-2. CB
07
O
O
14.1 Physical Dimension
150 mm (W) × 86 mm (H) × 160 mm (D)
14.2 Connectors Define
14. MECHANICAL REQUIREMENTS