SilverStone SST-ST50F-230 [3/12] St50f 230 2

SilverStone ST50F-230 [3/12] St50f 230 2
1.3.1 Cold Start
1.3.2 Warm Start
1.4 AC Input Current
1.5 Efficiency
The maximum efficiency >80% in the typical load and 230 Vac input voltage conditions.
2. Output Requirements
2.1 Output Regulations
Note:
(1) The above voltage range should also include ripple and noise.
(2) The output voltage should be measured at the terminals of output connector
.
LimitsConditions
No component over stress or damage should
occur to the power supply.
Input fuse shall not blow up .
No component over stress or damage should
occur to the power supply.
Input fuse shall not blow up .
230VAC, full load.
25
C ambient.
UnitsMAXAC Input
8230V
AMPS
MIN
+5.00
+12.00
+12.00
-12.00
+4.75
+11.40
+11.40
-10.80
Range Normal MAX Units
Volts
Volts
Volts
Volts
Output Voltage
5%
+12.60
+5.25
+12.60
-13.20
+5V
+12V1
+12V2
-12V
LimitsConditions
Turn off at 264VAC full load for 1 sec then
turn on at the peak of the input voltage cycle
at 25 C ambient.
5%
5%
10%
5%
5%
Volts
Volts+3.30
+5.00
+3.14
+4.75
+3.46
+5.25
+3.3V
+5Vsb
±
±
±
±
±
±