Refrigerant piping.
CAUTION
1) Use the flare nut fixed to the main unit. (To prevent cracking of the flare nut by aged deterioration.)
2) To prevent gas leakage, apply refrigeration oil only to the inner surface of the flare. (Use refrigeration oil for R410A.)
3) Use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage.
Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand. Then tighten them fully with the torque wrenches.
2-1.
Caution on Piping Handling
1) Protect the open end of the pipe against dust and moisture.
2) All pipe bends should be as gentle as possible. Use a pipe bender
for bending.
2-2.
Selection of Copper and Heat Insulation materials
• When using commercial copper pipes and fittings, observe the following:
1) Insulation material: Polyethylene foam
Heat transfer rate: 0.041 to 0.052W/mK (0.035 to 0.045kcal/mh°C)
Refrigerant gas pipe’s surface temperature reaches 110°C max.
Choose heat insulation materials that will withstand this temperature.
2) Be sure to insulate both the gas and liquid piping and to provide insulation dimen-
sions as below.
3) Use separate thermal insulation pipes for gas and liquid refrigerant pipes.
Gas side Liquid side
Gas pipe thermal insulation
Liquid pipe
thermal insulation
50/60 class 71 class 50/60/71 class 50/60 class 71 class 50/60/71 class
O.D. 12.7mm O.D. 15.9mm O.D. 6.4mm I.D. 14-16mm I.D. 16-20mm I.D. 8-10mm
Minimum bend radius Thickness 10mm Min.
40mm or more 50mm or more 30mm or more
Thickness 0.8mm
(C1220T-O)
Thickness 1.0mm
(C1220T-O)
Thickness 0.8mm
(C1220T-O)
Torque wrench
Piping union
Flare nut
Do not apply refrigeration
oil to the outer surface.
Flare nut
Apply refrigeration oil to
the inner surface of the
flare.
Do not apply refrigeration
oil to the flare nut avoid
tightening with over torque.
Spanner
[Apply oil] [Tighten]
Flare nut tightening torque
Gas side Liquid side
1/2 inch 5/8 inch 1/4 inch
49.5-60.3N
m 61.8-75.4N m 14.2-17.2N m
(505-615kgf
cm) (630-770kgf cm) (144-175kgf cm)
Valve cap tightening torque
Wall
If no flare cap is
available, cover
the flare mouth
with tape to keep
dirt or water out.
Be sure to
place a cap.
Rain
Gas pipe
Liquid pipe
Gas pipe
insulation
Liquid pipe
insulation
Finishing tape
Drain hose
Inter-unit wiring
01_EN_3P190114-1D.fm Page 10 Monday, August 23, 2010 3:35 PM
Содержание
- Ftxs50fv1b ftks50fv1b ftxs60fv1b ftks60fv1b ftxs71fv1b ftks71fv1b ftx50gv1b ftx60gv1b ftx71gv1b 1
- Installation manual 1
- Inverter models 1
- Non inverter models ftyn50fv1b ftn50fv1b ftyn60fv1b ftn60fv1b 1
- R410a split series 1
- Daikin industries ltd 2
- Low voltage 2006 95 ec electromagnetic compatibility 2004 108 e 2
- Sb64526 5f 2
- Shinri sada manager quality control department 25th of nov 2009 2
- Umeda center bldg 2 4 12 nakazaki nishi kita ku osaka 530 8323 japan 2
- Caution 3
- English 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Choosing a site 4
- English 2 4
- Indoor unit 4
- Installation tips 4
- Removing and installing front panel 4
- Wireless remote controller 4
- Caution 5
- How to set the different addresses 5
- Installation tips 5
- Removing and installing front grille 5
- When there is no work space because the unit is close to ceiling 5
- Caution 6
- English 4 6
- Indoor unit installation drawings 6
- Intelligent eye sensor ftxs ftx ftks only 6
- English 7
- Indoor unit installation 7
- Installing the mounting plate 7
- Boring a wall hole and installing wall embedded pipe 8
- English 6 8
- Installing indoor unit 8
- Right side right back or right bottom piping 8
- 2 left side left back or left bottom piping 9
- 3 wall embedded piping 9
- English 9
- Indoor unit installation 9
- English 8 10
- Warning 10
- When connecting to an ha system 10
- Wiring 10
- Do not put the end of the hose in water 11
- Drain piping 11
- Flaring 11
- Flaring the pipe end 11
- Indoor unit drain hose 11
- Indoor unit installation 11
- No trap is permitted 11
- Refrigerant piping work 11
- The drain hose should be inclined downward 11
- Warning 11
- _en_3p190114 1d fm page 9 monday august 23 2010 3 35 pm 11
- Caution 12
- English 10 12
- O d 12 mm o d 15 mm o d 6 mm i d 14 16mm i d 16 20mm i d 8 10mm 12
- Refrigerant piping 12
- Test items 13
- Trial operation and testing 13
- Trial operation from remote controller 13
- P190114 1d m06b094d 14
Похожие устройства
- Daikin FTXLS25K3V1B Технические данные
- Daikin FTXLS25K3V1B Инструкция по монтажу
- Daikin FTXLS25K3V1B Инструкция по эксплуатации
- Daikin FTN60FV1B Диагностика
- Daikin FTXLS35K3V1B Технические данные
- Daikin FTXLS35K3V1B Инструкция по монтажу
- Daikin FTXLS35K3V1B Инструкция по эксплуатации
- Daikin FVXG25K2V1B Инструкция по монтажу
- Daikin FVXG25K2V1B Технические данные
- Daikin FVXG25K2V1B Инструкция по эксплуатации
- Daikin FVXG25K2V1B Сервис мануал
- Daikin FVXG35K2V1B Инструкция по монтажу
- Daikin FVXG35K2V1B Инструкция по эксплуатации
- Daikin FVXG35K2V1B Технические данные
- Daikin FVXG35K2V1B Сервис мануал
- Daikin FVXG50K2V1B Инструкция по эксплуатации
- Daikin FVXG50K2V1B Инструкция по монтажу
- Daikin FVXG50K2V1B Технические данные
- Daikin FVXG50K2V1B Сервис мануал
- Daikin FVXS25FV1B Технические данные