Daikin FLKS60BAVMB [6/15] Indoor unit installation drawings
![Daikin FLKS60BAVMB [6/15] Indoor unit installation drawings](/views2/1720624/page6/bg6.png)
■English 4
Indoor Unit
Installation Drawings
O
N
O
F
F
50mm or more
from floor
D
Screws
(Field supply:
M3 × 20L)
E
Caulk
pipe hole
gap with
putty.
Cut thermal insulation pipe to an
appropriate length and wrap it with tape,
making sure that no gap is left in the
insulation pipe’s cut line.
Wrap the insulation
pipe with the
finishing tape from
bottom to top.
Before screwing the remote
controller holder to the wall, make
sure that control signals are
properly received by indoor unit.
Remote
controller
holder
Wireless
remote
controller
Space for
installation
work Min.
(200mm)
Space for
installation
work Min.
(200mm)
Mounting plate
A
Screws
(Field supply:
M4 × 25L)
50mm or more
from walls
There should be no space
between ceiling and the unit.
Space for installation work
Min. (200mm)
Space for installation work
Min. (200mm)
The mounting plate
should be installed
on a wall which can
support the weight
of the indoor unit.
Air filters
Hold the recessed
parts of the frame
and unhook the four
claws.
B Photocatalytic
deodorizing filter
C Air purifying filter
B Photocatalytic
deodorizing filter or
C Air purifying filter
01_EN_3P171284-2D.fm Page 4 Monday, August 23, 2010 2:33 PM
Содержание
- Flxs25bvmb flks25bvmb flxs35bvmb flks35bvmb flxs50bvmb flks50bvmb flxs60bvmb flks60bvmb flx25bvmb flk25bvmb flx35bvmb flk35bvmb flxs25bavmb flks25bavmb flxs35bavmb flks35bavmb flxs50bavmb flks50bavmb flxs60bavmb flks60bavmb 1
- Installation manual 1
- Models 1
- R410a split series 1
- Daikin industries ltd 2
- Low voltage 2006 95 ec electromagnetic compatibility 2004 108 e 2
- Sb64526 4 2
- Shinri sada manager quality control department 1st of nov 2008 2
- Umeda center bldg 2 4 12 nakazaki nishi kita ku osaka 530 8323 japan 2
- Caution 3
- English 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Choosing an installation site 4
- English 2 4
- Indoor unit 4
- Wireless remote controller 4
- Before installing the indoor unit 5
- English 5
- How to the different addresses 5
- In case of ceiling suspended use 5
- Installation tips 5
- Perform the following before installing the indoor unit 5
- Air filters 6
- B photocatalytic deodorizing filter c air purifying filter 6
- B photocatalytic deodorizing filter or c air purifying filter 6
- English 4 6
- Hold the recessed parts of the frame and unhook the four claws 6
- Indoor unit installation drawings 6
- Wrap the insulation pipe with the finishing tape from bottom to top 6
- Ceiling mounting 7
- English 7
- Indoor unit installation drawings 7
- Wall mounting 7
- Ceiling mounting 8
- English 6 8
- Indoor unit installation 8
- Installing indoor unit 8
- Installing the suspension bolt 8
- English 9
- Indoor unit installation 9
- Installation 9
- Wall mounting 9
- Commonality between ceiling mounting and wall mounting 10
- English 8 10
- Installing indoor unit 10
- Warning 10
- Wiring 10
- Drain piping 11
- English 11
- Indoor unit installation 11
- Insulation of refrigerant pipes 11
- Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand then tighten them fully with the torque wrenches 12
- Caution 12
- Cut the pipe end with a pipe cutter 2 remove burrs with the cut surface facing down ward so that the chips do not enter the pipe 3 put the flare nut on the pipe 4 flare the pipe 5 check that the flaring is properly made 12
- Do not use mineral oil on flared part 2 prevent mineral oil from getting into the system as this would reduce the lifetime of the units 3 never use piping which has been used for previous installations only use parts which are delivered with the unit 4 do never install a drier to this r410a unit in order to guarantee its lifetime 5 the drying material may dissolve and damage the system 6 incomplete flaring may cause refrigerant gas leakage 12
- Flaring the pipe end 12
- Protect the open end of the pipe against dust and moisture 2 all pipe bends should be as gentle as possible use a pipe bender for bending 12
- Refrigerant piping 12
- Refrigerant piping work 12
- Use the flare nut fixed to the main unit to prevent cracking of the flare nut by aged deterioration 2 to prevent gas leakage apply refrigeration oil only to the inner surface of the flare use refrigeration oil for r410a 3 use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage 12
- Warning 12
- 2 selection of copper and heat insulation materials 13
- English 13
- Refrigerant piping work 13
- Test items 14
- Trial operation and testing 14
- Trial operation from remote controller 14
- P171284 2d m02b074j 15
Похожие устройства
- Daikin FLKS60BAVMB Инструкция по эксплуатации
- Daikin FLKS60BAVMB Сервис мануал
- MSI GS66 Stealth 10SE-265RU Руководство пользователя
- MSI GS66 Stealth 10SGS-243RU Руководство пользователя
- MSI GS66 Stealth 10SFS-249RU Руководство пользователя
- MSI GS75 Stealth 8SG-036RU Руководство пользователя
- MSI GS75 Stealth 8SE-039RU Руководство пользователя
- MSI GS75 Stealth 8SF-038RU Руководство пользователя
- MSI GS65 Stealth 8SG-088RU Руководство пользователя
- MSI GS65 Stealth 8SF-089RU Руководство пользователя
- MSI GS65 Stealth 8SE-090RU Руководство пользователя
- MSI GS65 Stealth Thin 8RE Руководство пользователя
- MSI GS65 Stealth Thin 8RF Руководство пользователя
- MSI GE75 Raider 10SGS-213RU Руководство пользователя
- MSI GE75 Raider 10SFS-217RU Руководство пользователя
- MSI GE75 Raider 10SFS-268RU Руководство пользователя
- MSI GE75 Raider 10SGS-267RU Руководство пользователя
- MSI GE66 Raider 10SFS-029RU Руководство пользователя
- MSI GE66 Raider 10SGS-062RU Руководство пользователя
- MSI GE66 Raider 10SF-016RU Руководство пользователя