Daikin FLXS35BAVMB9 [6/17] Indoor unit
![Daikin FLXS35BAVMB9 [6/17] Indoor unit](/views2/1726135/page6/bg6.png)
■English 2
Accessories
–
• The extension auxiliary pipe is not included for FLX(S)25, FLX(S)35, FLK(S)25 and FLK(S)35.
Choosing an Installation Site
• Before choosing the installation site, obtain user approval.
1.
Indoor unit.
• The indoor unit should be sited in a place where:
1) the restrictions on installation specified in the indoor unit installation drawings are met,
2) both air intake and exhaust have clear paths met,
3) the unit is not in the path of direct sunlight,
4) the unit is away from the source of heat or steam,
5) there is no source of machine oil vapour (this may shorten indoor unit life),
6) cool air is circulated throughout the room,
7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the
remote control range,
8) the unit is at least 1 metre away from any television or radio set (unit may cause interference with the picture or sound).
2.
Wireless remote controller.
1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote control signals are properly received
by the indoor unit (within 7 metres).
• This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for
commercial and household use by lay persons.
• Sound pressure level is less than 70 dB (A).
Mounting plate
1
AAA dry-cell batteries
2
Heat insulation tube
(Extension auxiliary pipe)
1
Photocatalytic deodorizing filter
1
Side covers
2
Heat insulation tube
(Refrigerant pipe)
1
Air purifying filter
1
Operation manual
1
Binding bands
4
Wireless remote controller
1
Installation manual
1
Remote controller holder
1
Extension auxiliary pipe
2
Indoor unit
A
Q
A
G
N
B
J
P
C
K
Q
D
L
E
M
M N
01_EN_3P171284-2E.fm Page 2 Thursday, August 22, 2013 12:53 PM
Содержание
- Flxs25bvmb flks25bvmb flxs35bvmb flks35bvmb flxs50bvmb flks50bvmb flxs60bvmb flks60bvmb flx25bvmb flk25bvmb flx35bvmb flk35bvmb flxs25bavmb flks25bavmb flxs35bavmb flks35bavmb flxs50bavmb flks50bavmb flxs60bavmb flks60bavmb flxs35bavmb9 1
- Installation manual 1
- Models 1
- R410a split series 1
- Daikin industries ltd 2
- Low voltage 2006 95 ec electromagnetic compatibility 2004 108 e 2
- Sb64526 4 2
- Shinri sada manager quality control department 1st of nov 2008 2
- Umeda center bldg 2 4 12 nakazaki nishi kita ku osaka 530 8323 japan 2
- Daikin industries czech republic s r o 3
- En60335 2 4 3
- Flxs35bavmb9 3
- Machinery 2006 42 ec electromagnetic compatibility 2004 108 ec low voltage 2006 95 ec 3
- P327445 11f 3
- Takayuki fujii managing director pilsen 1st of nov 2013 3
- Caution 5
- English 5
- Safety precautions 5
- Warning 5
- Accessories 6
- Choosing an installation site 6
- English 2 6
- Indoor unit 6
- Wireless remote controller 6
- Before installing the indoor unit 7
- English 7
- How to the different addresses 7
- In case of ceiling suspended use 7
- Installation tips 7
- Perform the following before installing the indoor unit 7
- Air filters 8
- B photocatalytic deodorizing filter c air purifying filter 8
- B photocatalytic deodorizing filter or c air purifying filter 8
- English 4 8
- Hold the recessed parts of the frame and unhook the four claws 8
- Indoor unit installation drawings 8
- Wrap the insulation pipe with the finishing tape from bottom to top 8
- Ceiling mounting 9
- English 9
- Indoor unit installation drawings 9
- Wall mounting 9
- Ceiling mounting 10
- English 6 10
- Indoor unit installation 10
- Installing indoor unit 10
- Installing the suspension bolt 10
- English 11
- Indoor unit installation 11
- Installation 11
- Wall mounting 11
- Commonality between ceiling mounting and wall mounting 12
- English 8 12
- Installing indoor unit 12
- Warning 12
- Wiring 12
- Drain piping 13
- English 13
- Indoor unit installation 13
- Insulation of refrigerant pipes 13
- Align the centres of both flares and tighten the flare nuts 3 or 4 turns by hand then tighten them fully with the torque wrenches 14
- Caution 14
- Cut the pipe end with a pipe cutter 2 remove burrs with the cut surface facing down ward so that the chips do not enter the pipe 3 put the flare nut on the pipe 4 flare the pipe 5 check that the flaring is properly made 14
- Do not use mineral oil on flared part 2 prevent mineral oil from getting into the system as this would reduce the lifetime of the units 3 never use piping which has been used for previous installations only use parts which are delivered with the unit 4 do never install a drier to this r410a unit in order to guarantee its lifetime 5 the drying material may dissolve and damage the system 6 incomplete flaring may cause refrigerant gas leakage 14
- Flaring the pipe end 14
- Protect the open end of the pipe against dust and moisture 2 all pipe bends should be as gentle as possible use a pipe bender for bending 14
- Refrigerant piping 14
- Refrigerant piping work 14
- Use the flare nut fixed to the main unit to prevent cracking of the flare nut by aged deterioration 2 to prevent gas leakage apply refrigeration oil only to the inner surface of the flare use refrigeration oil for r410a 3 use torque wrenches when tightening the flare nuts to prevent damage to the flare nuts and gas leakage 14
- Warning 14
- 2 selection of copper and heat insulation materials 15
- English 15
- Refrigerant piping work 15
- Test items 16
- Trial operation and testing 16
- Trial operation from remote controller 16
- P171284 2e m02b074k 17
Похожие устройства
- Noirot CNX-4 plus 2000 Инструкция по эксплуатации
- Daikin FLXS35BAVMB9 Инструкция по эксплуатации
- Daikin FLXS35BAVMB9 Сервис мануал
- Noirot Spot E-3 plus 750 Инструкция по эксплуатации
- Noirot Spot E-3 plus 2000 Инструкция по эксплуатации
- Noirot Spot E-5 plus 2000 Инструкция по эксплуатации
- Gorenje B800ORAB Инструкция по эксплуатации
- Gorenje B800ORAW Инструкция по эксплуатации
- Gorenje HB600ORAB Инструкция по эксплуатации
- Gorenje HB600ORAW Инструкция по эксплуатации
- Sven KT-D2004 Инструкция по эксплуатации
- Sven KT-D1705 Инструкция по эксплуатации
- Braun 4200-MQ9047X Инструкция по эксплуатации
- Maunfeld MFT-815BG Инструкция по эксплуатации
- Maunfeld MFT-815CH Инструкция по эксплуатации
- Maunfeld MFT-847BK Инструкция по эксплуатации
- Schaub Lorenz SLK GS6520 Инструкция по эксплуатации
- Kitfort КТ-938 Инструкция по эксплуатации
- Kitfort КТ-939 Инструкция по эксплуатации
- Kitfort КТ-940 Инструкция по эксплуатации