Drazice UKV 102 [12/21] Volume and flow increaser

Drazice UKV 102 [12/21] Volume and flow increaser
GB
UKV
102
9
Tillsatsvärme
FG
Volume and flow increaser
93
35
89
35
120
99
94
VP1
In
cases
where the
system volume
in the radiator circuit
is
below 20 l/kW
(heat
pump output at 7/45
°C)
and/or the
radiator ow
is choked
uncontrolled, a
UKV
tank
is installed as
a
volume
and ow
increaser. The T-coupling
must be po-
sitioned as close
to the
UKV
tank
as
possible.
Volume and flow increaser
101
31
Additional
heat
120
35
T
P
VP1
For large houses
and apartment
buildings, industrial premises
or
similar
with
supply
air batteries.
The accumulator
tank
is used as
a buffer for the
supply
air coil.
The T-coupling
must be
positioned as close
to the UKV
tank
as
possible.
Note!
These are
outline
diagrams.
Actual
installations
must be
planned according
to
applicable
standards.