Safety Precautions
• The precautions described herein are classified as WARNING and CAUTION. They both contain important
information regarding safety. Be sure to observe all precautions without fail.
• Meaning of WARNING and CAUTION notices
WARNING.....Failure to follow these instructions properly may result in personal injury or loss of life.
CAUTION......Failure to observe these instructions properly may result in property damage or personal injury, which
may be serious depending on the circumstances.
• The safety marks shown in this manual have the following meanings:
• After completing installation, conduct a trial operation to check for faults and explain to the customer how to operate
the air conditioner and take care of it with the aid of the operation manual.
• The English text is the original instruction. Other languages are translations of the original instructions.
Be sure to follow the instructions. Be sure to establish an earth connection. Never attempt.
WARNING
• Ask your dealer or qualified personnel to carry out installation work.
Do not attempt to install the air conditioner yourself. Improper installation may result in water leakage, electric shocks or fire.
• Install the air conditioner in accordance with the instructions in this installation manual.
Improper installation may result in water leakage, electric shocks or fire.
• Be sure to use only the specified accessories and parts for installation work.
Failure to use the specified parts may result in the unit falling, water leakage, electric shocks or fire.
• Install the air conditioner on a foundation strong enough to withstand the weight of the unit.
A foundation of insufficient strength may result in the equipment falling and causing injury.
• Electrical work must be performed in accordance with relevant local and national regulations and with instructions
in this installation manual. Be sure to use a dedicated power supply circuit only.
Insufficiency of power circuit capacity and improper workmanship may result in electric shocks or fire.
• Use a cable of suitable length.
Do not use tapped wires or an extension lead, as this may cause overheating, electric shocks or fire.
• Make sure that all wiring is secured, the specified wires are used, and that there is no strain on the terminal
connections or wires.
Improper connections or securing of wires may result in abnormal heat build-up or fire.
• When wiring the power supply and connecting the wiring between the indoor and outdoor units, position the wires
so that the control box lid can be securely fastened.
Improper positioning of the control box lid may result in electric shocks, fire or over heating terminals.
• If the supply cord is damaged, it must be replaced by the manufacturer, a service agent or similarly qualified
persons in order to avoid a hazard.
• If refrigerant gas leaks during installation, ventilate the area immediately.
Toxic gas may be produced if the refrigerant comes into contact with fire.
• After completing installation, check for refrigerant gas leakage.
Toxic gas may be produced if the refrigerant gas leaks into the room and comes into contact with a source of fire, such as a fan heater,
stove or cooker.
• When installing or relocating the air conditioner, be sure to bleed the refrigerant circuit to ensure it is free of air,
and use only the specified refrigerant (R410A).
The presence of air or other foreign matter in the refrigerant circuit causes abnormal pressure rise, which may result in equipment damage
and even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the refrigerant pipes are not attached and the stop valve is open when the compressor is run, air will be sucked in, causing abnormal
pressure in the refrigeration cycle, which may result in equipment damage and even injury.
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the refrigeration cycle, which may result in equipment damage and even injury.
• Be sure to earth the air conditioner.
Do not earth the unit to a utility pipe, lightning conductor or telephone earth lead. Imperfect earthing may result in electric shocks.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks or fire.
Содержание
- Installation manual 1
- Models 1
- R410a split series 1
- Daikin industries czech republic s r o 2
- Electromagnetic compatibility 2004 108 ec low voltage 2006 95 ec 2
- En60335 2 4 2
- Ftxl25j2v1b ftxl35j2v1b atxl25j2v1b atxl35j2v1b 2
- P363628 4c 2
- P377527 2d book page 1 monday april 24 2017 6 58 pm 2
- Takayuki fujii managing director pilsen 1st of aug 2014 2
- English 1 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Caution 4
- Choosing an installation site 4
- English 4
- Indoor unit 4
- Wireless remote controller 4
- Caution 5
- How to set the different addresses 5
- Installation tips 5
- Removing and installing front grille 5
- Removing and installing front panel 5
- When there is no work space because the unit is close to ceiling 5
- English 6
- Indoor unit installation drawings 6
- English 5 7
- Indoor unit installation 7
- Installing the mounting plate 7
- Boring a wall hole and installing wall embedded pipe 8
- Caution 8
- Indoor unit installation 8
- Installing the indoor unit 8
- English 9
- English 7 9
- Indoor unit installation 9
- Right side right back or right bottom piping 9
- 2 left side left back or left bottom piping 10
- 3 wall embedded piping 10
- Attachment on the right side factory default 10
- English 10
- How to replace the drain plug and drain hose 10
- Indoor unit installation 10
- No gap 10
- Replacing onto the left side 10
- English 9 11
- Indoor unit installation 11
- Unified wiring diagram legend 11
- Indoor unit installation 12
- Warning 12
- When connecting to a wired remote controller 12
- Wiring 12
- Cut outs for the connection cords 13
- English 11 13
- Indoor unit installation 13
- Install the accessory separate product figure 3 13
- Install the cover of the electrical component box in its original position figure 3 13
- Install the front grille in its original position 2 screws 13
- Install the indoor unit electrical component box in its original position 13
- Install the service lid 1 screw 13
- Prepare the accessory separate product figure 2 13
- Drain piping 14
- Flaring the pipe end 14
- Indoor unit installation 14
- Refrigerant piping work 14
- Warning 14
- Caution 15
- Refrigerant piping 15
- Refrigerant piping work 15
- English 16
- Test items 16
- Trial operation and testing 16
- Trial operation from remote controller 16
Похожие устройства
- Daikin ATXL25J2V1B Руководство по монтажу
- Daikin ATXL35J2V1B Инструкция по эксплуатации
- Daikin ATXL35J2V1B Инструкция по монтажу
- Daikin ATXL35J2V1B Руководство по монтажу
- Daikin ATX20J2V1B Сервис мануал
- Daikin ATX20J2V1B Инструкция по эксплуатации
- Daikin ATX20J2V1B Инструкция по монтажу
- Daikin ATX25J2V1B Сервис мануал
- Daikin ATX25J2V1B Инструкция по эксплуатации
- Daikin ATX25J2V1B Инструкция по монтажу
- Daikin ATX35J2V1B Сервис мануал
- Daikin ATX35J2V1B Инструкция по эксплуатации
- Daikin ATX35J2V1B Инструкция по монтажу
- Daikin ATX20J3V1B Сервис мануал
- Daikin ATX20J3V1B Инструкция по эксплуатации
- Daikin ATX20J3V1B Инструкция по монтажу
- Daikin ATX25J3V1B Сервис мануал
- Daikin ATX25J3V1B Инструкция по монтажу
- Daikin ATX25J3V1B Инструкция по эксплуатации
- Daikin ATX35J3V1B Сервис мануал