Daikin ATXL25J2V1B [4/20] Indoor unit
![Daikin ATXL25J2V1B [4/20] Indoor unit](/views2/1746295/page4/bg4.png)
2 English
Accessories
–
Choosing an Installation Site
Before choosing the installation site, obtain user approval.
1. Indoor unit.
• The indoor unit should be sited in a place where:
1) the restrictions on installation specified in the indoor unit installation drawings are met,
2) both air intake and exhaust have clear paths met,
3) the unit is not in the path of direct sunlight,
4) the unit is away from the source of heat or steam,
5) there is no source of machine oil vapour (this may shorten indoor unit life),
6) cool (warm) air is circulated throughout the room,
7) the unit is away from electronic ignition type fluorescent lamps (inverter or rapid start type) as they may shorten the remote
control range,
8) the unit is at least 1m away from any television or radio set (unit may cause interference with the picture or sound),
9) install at the recommended height (1.8m).
2. Wireless remote controller.
1) Turn on all the fluorescent lamps in the room, if any, and find the site where remote controller signals are properly received
by the indoor unit (within 7 metres).
CAUTION
• Do not install the air conditioner at any place where there is a danger of flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
• While following the instructions in this installation manual, install drain piping to ensure proper drainage
and insulate piping to prevent condensation.
Improper drain piping may result in indoor water leakage and property damage.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is too tight, it may crack after prolonged use, causing refrigerant leakage.
• This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for
commercial and household use by lay persons.
• Sound pressure level is less than 70 dB(A).
Mounting plate
1
Remote controller holder
1
Operation manual
1
Titanium apatite deodorizing
filter
2
AAA dry-cell batteries
2
Installation manual
1
Wireless remote controller
1
Indoor unit fixing screws
(M4 × 12L)
2
Indoor unit
A
L
A
E
K
B
G
L
D
H
Содержание
- Installation manual 1
- Models 1
- R410a split series 1
- Daikin industries czech republic s r o 2
- Electromagnetic compatibility 2004 108 ec low voltage 2006 95 ec 2
- En60335 2 4 2
- Ftxl25j2v1b ftxl35j2v1b atxl25j2v1b atxl35j2v1b 2
- P363628 4c 2
- P377527 2d book page 1 monday april 24 2017 6 58 pm 2
- Takayuki fujii managing director pilsen 1st of aug 2014 2
- English 1 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Caution 4
- Choosing an installation site 4
- English 4
- Indoor unit 4
- Wireless remote controller 4
- Caution 5
- How to set the different addresses 5
- Installation tips 5
- Removing and installing front grille 5
- Removing and installing front panel 5
- When there is no work space because the unit is close to ceiling 5
- English 6
- Indoor unit installation drawings 6
- English 5 7
- Indoor unit installation 7
- Installing the mounting plate 7
- Boring a wall hole and installing wall embedded pipe 8
- Caution 8
- Indoor unit installation 8
- Installing the indoor unit 8
- English 9
- English 7 9
- Indoor unit installation 9
- Right side right back or right bottom piping 9
- 2 left side left back or left bottom piping 10
- 3 wall embedded piping 10
- Attachment on the right side factory default 10
- English 10
- How to replace the drain plug and drain hose 10
- Indoor unit installation 10
- No gap 10
- Replacing onto the left side 10
- English 9 11
- Indoor unit installation 11
- Unified wiring diagram legend 11
- Indoor unit installation 12
- Warning 12
- When connecting to a wired remote controller 12
- Wiring 12
- Cut outs for the connection cords 13
- English 11 13
- Indoor unit installation 13
- Install the accessory separate product figure 3 13
- Install the cover of the electrical component box in its original position figure 3 13
- Install the front grille in its original position 2 screws 13
- Install the indoor unit electrical component box in its original position 13
- Install the service lid 1 screw 13
- Prepare the accessory separate product figure 2 13
- Drain piping 14
- Flaring the pipe end 14
- Indoor unit installation 14
- Refrigerant piping work 14
- Warning 14
- Caution 15
- Refrigerant piping 15
- Refrigerant piping work 15
- English 16
- Test items 16
- Trial operation and testing 16
- Trial operation from remote controller 16
Похожие устройства
- Daikin ATXL25J2V1B Руководство по монтажу
- Daikin ATXL35J2V1B Инструкция по эксплуатации
- Daikin ATXL35J2V1B Инструкция по монтажу
- Daikin ATXL35J2V1B Руководство по монтажу
- Daikin ATX20J2V1B Сервис мануал
- Daikin ATX20J2V1B Инструкция по эксплуатации
- Daikin ATX20J2V1B Инструкция по монтажу
- Daikin ATX25J2V1B Сервис мануал
- Daikin ATX25J2V1B Инструкция по эксплуатации
- Daikin ATX25J2V1B Инструкция по монтажу
- Daikin ATX35J2V1B Сервис мануал
- Daikin ATX35J2V1B Инструкция по эксплуатации
- Daikin ATX35J2V1B Инструкция по монтажу
- Daikin ATX20J3V1B Сервис мануал
- Daikin ATX20J3V1B Инструкция по эксплуатации
- Daikin ATX20J3V1B Инструкция по монтажу
- Daikin ATX25J3V1B Сервис мануал
- Daikin ATX25J3V1B Инструкция по монтажу
- Daikin ATX25J3V1B Инструкция по эксплуатации
- Daikin ATX35J3V1B Сервис мануал