Daikin ATX35J2V1B [4/18] English
![Daikin ATX20J3V1B [4/18] English](/views2/1746308/page4/bg4.png)
1 English
Safety Precautions
• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into WARNING and CAUTION.
Be sure to follow all the precautions below: they are all important for ensuring safety.
WARNING
........ Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTION......... Failure to follow any of CAUTION may result in grave consequences in some cases.
• The following safety symbols are used throughout this manual:
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions
concerning the use and cleaning of the unit according to the Operation Manual.
• The English text is the original instruction. Other languages are translations of the original instructions.
Be sure to observe this instruction. Be sure to establish an earth connection. Never attempt.
WARNING
• Installation should be left to the dealer or another professional.
Improper installation may cause water leakage, electrical shock, or fire.
• Install the air conditioner according to the instructions given in this manual.
Incomplete installation may cause water leakage, electrical shock, or fire.
• Be sure to use the supplied or specified installation parts.
Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire.
• Install the air conditioner on a solid base that can support the weight of the unit.
An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.
• Electrical work should be carried out in accordance with the installation manual and the national electrical wiring
rules or code of practice.
Insufficient capacity or incomplete electrical work may cause electrical shock or fire.
• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
• For wiring, use a cable length enough to cover the entire distance with no connection.
Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit.
(Failure to do so may cause abnormal heat, electric shock or fire.)
• Use the specified types of wires for electrical connections between the indoor and outdoor units.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating or fire.
• After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force
on the electrical covers or panels.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire.
• If the supply cord is damaged, it must be replaced by the manufacturer, a service agent or similarly qualified
persons in order to avoid a hazard.
• If any refrigerant has leaked out during the installation work, ventilate the room.
(The refrigerant produces a toxic gas if exposed to flames.)
• After all installation is complete, check to make sure that no refrigerant is leaking out.
(The refrigerant produces a toxic gas if exposed to flames.)
• When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the
specified refrigerant (R410A), such as air.
(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the stop valve is open during pump-down, air will be sucked in when the compressor is run, causing
abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.
Incomplete earth may cause electrical shock, or fire. A high surge current from lightning or other sources may cause damage to the
air conditioner.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks, or fire.
CAUTION
• Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.
• Establish drain piping according to the instructions of this manual.
Inadequate piping may cause flooding.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.
3PEN479172-2.book Page 1 Friday, March 3, 2017 1:51 PM
Содержание
- Installation manual 1
- Models 1
- R410a split series 1
- Daikin industries czech republic s r o 2
- Low voltage 2006 95 ec electromagnetic compatibility 2004 108 e 2
- P290872 2 2
- Takayuki fujii managing director 1s t of jun 20 11 2
- U nove hospody 1 1155 301 00 plzen skvrnany czech republic 2
- Daikin industries czech republic s r o 3
- Electromagnetic compatibility 2004 108 ec low voltage 2006 95 ec 3
- En60335 2 4 3
- Ftx20j3v1b ftx25j3v1b ftx35j3v1b atx20j3v1b atx25j3v1b atx35j3v1b 3
- P390250 1 3
- P479172 2 book page 1 wednesday may 3 2017 12 53 pm 3
- Takayuki fujii managing director pilsen 1st of dec 2014 3
- Caution 4
- English 4
- Safety precautions 4
- Warning 4
- Accessories 5
- Choosing an installation site 5
- English 2 5
- Indoor unit 5
- Wireless remote controller 5
- Caution 6
- How to set the different addresses 6
- Installation tips 6
- Removing and installing front grille 6
- Removing and installing front panel 6
- When there is no work space because the unit is close to ceiling 6
- English 7
- English 4 7
- Indoor unit installation drawings 7
- English 8
- Indoor unit installation 8
- Installing the mounting plate 8
- Boring a wall hole and installing wall embedded pipe 9
- English 6 9
- Indoor unit installation 9
- Installing the indoor unit 9
- 2 left side left back or left bottom piping 10
- 3 wall embedded piping 10
- Attachment on the right side factory default 10
- English 10
- How to replace the drain plug and drain hose 10
- Indoor unit installation 10
- Mounting plate 10
- No gap 10
- Replacing onto the left side 10
- English 8 11
- Indoor unit installation 11
- Wiring diagram 11
- Indoor unit installation 12
- Warning 12
- When connecting to a wired remote controller 12
- Wiring 12
- Cut outs for the connection cords 13
- English 10 13
- Indoor unit installation 13
- Install the accessory separate product figure 3 13
- Install the cover of the electrical component box in its original position figure 3 13
- Install the front grille in its original position 2 screws 13
- Install the indoor unit electrical component box in its original position 13
- Install the service lid 1 screw 13
- Prepare the accessory separate product figure 2 13
- Drain piping 14
- Flaring the pipe end 14
- Indoor unit installation 14
- Refrigerant piping work 14
- Warning 14
- Caution 15
- Refrigerant piping 15
- Refrigerant piping work 15
- English 16
- Test items 16
- Trial operation and testing 16
- Trial operation from remote controller 16
- Blank page 17
Похожие устройства
- Daikin ATX20J3V1B Сервис мануал
- Daikin ATX20J3V1B Инструкция по эксплуатации
- Daikin ATX20J3V1B Инструкция по монтажу
- Daikin ATX25J3V1B Сервис мануал
- Daikin ATX25J3V1B Инструкция по монтажу
- Daikin ATX25J3V1B Инструкция по эксплуатации
- Daikin ATX35J3V1B Сервис мануал
- Daikin ATX35J3V1B Инструкция по монтажу
- Daikin ATX35J3V1B Инструкция по эксплуатации
- Daikin FTX20K5V1B Инструкция по эксплуатации
- Daikin FTX20K5V1B Инструкция по монтажу
- Daikin FTX20K2V1B Инструкция по эксплуатации
- Daikin FTX20K2V1B Инструкция по монтажу
- Daikin FTX25K5V1B Инструкция по эксплуатации
- Daikin FTX25K5V1B Инструкция по монтажу
- Daikin FTX25K2V1B Инструкция по эксплуатации
- Daikin FTX25K2V1B Инструкция по монтажу
- Daikin FTX35K5V1B Инструкция по эксплуатации
- Daikin FTX35K5V1B Инструкция по монтажу
- Daikin FTX35K2V1B Инструкция по эксплуатации