Daikin EHVZ04S18CB3V [3/8] 5 04 08 _ 6 16 4p401673 1a 2017 4

Daikin EHVZ08S18CB3V [3/8] 5 04 08 _ 6 16 4p401673 1a 2017 4
3/8
Breadcrumb Field code Setting name Range, step
Default valu
e
Date Value
User settings
└─ Preset values
└─ Room temperature
7.4.1.1 R/W [3-07]~[3-06], step: A.3.2.4
21°C
7.4.1.2 R/W [3-07]~[3-06], step: A.3.2.4
19°C
└─ LWT main
7.4.2.1 [8-09] R/W [9-01]~[9-00], step: 1°C
35°C
7.4.2.2 [8-0A] R/W [9-01]~[9-00], step: 1°C
33°C
7.4.2.5 R/W -10~10°C, step: 1°C
0°C
7.4.2.6 R/W -10~10°C, step: 1°C
-2°C
└─ Tank temperature
7.4.3.1 [6-0A] R/W 30~[6-0E]°C, step: 1°C
60°C
7.4.3.2 [6-0B] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
7.4.3.3 [6-0C] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
└─ Quiet level
7.4.4 R/W
0: Level 1 (*6)
1: Level 2 (*5)
2: Level 3
└─ Electricity price
7.4.5.1 [C-0C]
[D-0C]
R/W 0,00~990/kWh
0/kWh
7.4.5.2 [C-0D]
[D-0D]
R/W 0,00~990/kWh
0/kWh
7.4.5.3 [C-0E]
[D-0E]
R/W 0,00~990/kWh
0/kWh
└─ Fuel price
7.4.6 R/W 0,00~990/kWh
0,00~290/MBtu
8,0/kWh
└─ Set weather dependent
└─ Main
└────────────────── Set weather-dependent heating
7.7.1.1 [1-00] Set weather-dependent heating Low ambient temp. for LWT main zone heating
WD curve.
R/W -40~5°C, step: 1°C
-10°C
7.7.1.1 [1-01] Set weather-dependent heating High ambient temp. for LWT main zone heating
WD curve.
R/W 10~25°C, step: 1°C
15°C
7.7.1.1 [1-02] Set weather-dependent heating Leaving water value for low ambient temp. for
LWT main zone heating WD curve.
R/W
[9-01]~[9-00]°C, step: 1°C
35°C
7.7.1.1 [1-03] Set weather-dependent heating Leaving water value for high ambient temp. for
LWT main zone heating WD curve.
R/W [9-01]~min(45, [9-00])°C , step: 1°C
25°C
└─ Additional
└────────────────── Set weather-dependent heating
7.7.2.1 [0-00] Set weather-dependent heating Leaving water value for high ambient temp. for
LWT add zone heating WD curve.
R/W [9-05]~min(45,[9-06])°C, step: 1°C
35°C
7.7.2.1 [0-01] Set weather-dependent heating Leaving water value for low ambient temp. for
LWT add zone heating WD curve.
R/W [9-05]~[9-06]°C, step: 1°C
45°C
7.7.2.1 [0-02] Set weather-dependent heating High ambient temp. for LWT add zone heating
WD curve.
R/W 10~25°C, step: 1°C
15°C
7.7.2.1 [0-03] Set weather-dependent heating Low ambient temp. for LWT add zone heating
WD curve.
R/W -40~5°C, step: 1°C
-10°C
Installer settings
└─ System layout
└─ Standard
A.2.1.1 [E-00] R/O 0~5
0: LT s
p
lit
A.2.1.2 [E-01] R/O
0: 8 (*5)
1: 16
(
*6
)
A.2.1.3 [E-02] R/O
1: T
yp
e 2
A.2.1.4 [E-03] R/O
1: 1 ste
p
A.2.1.5 [5-0D] R/O
1: 1P,
(
1/1+2
)
A.2.1.6 [D-01] R/W
0: No
1: Open tariff
2: Closed tariff
3: Thermostat
A.2.1.7 [C-07] R/W 0: LWT control
1: Ext RT control
2: RT control
A.2.1.8 [7-02] R/W 0: 1 LWT zone
1: 2 LWT zones
A.2.1.9 [F-0D] R/W 0: Continuous
1: Sample
2: Re
q
ues
t
A.2.1.A [E-04] R/O
0: No (*6)
1: Yes
(
*5
)
A.2.1.B R/W 0: At unit
1: In room
└─ Options
A.2.2.1 [E-05] R/W
0: No
1: Yes
A.2.2.3 [E-07] R/O 0~6
1: T
yp
e 2
A.2.2.4 [C-05] R/W 1: Thermo ON/OFF
2: C/H re
ues
A.2.2.5 [C-06] R/W 1: Thermo ON/OFF
2: C/H re
ues
A.2.2.6.1 [C-02] Digital I/O PCB Ext. backup heat src R/W
0~3
0: No
1: Bivalent
A.2.2.6.2 [D-07] Digital I/O PCB Solar kit R/O
0~1
0: No
A.2.2.6.3 [C-09] Digital I/O PCB Alarm output R/W
0: Normally open
1: Normall
y
closed
A.2.2.6.4 [F-04] Digital I/O PCB Bottom plate heater R/W
0: No
1: Yes
A.2.2.7 [D-04] R/W
0: No
1: Pwr consm
p
ctrl
Forced off contact
Contact type add.
Demand PCB
Pump operation mode
Power saving possible
User interface location
DHW operation
DHW tank type
Contact type main
Indoor software type
Backup heater steps
BUH type
Unit control method
Number of LWT zones
High
Medium
Low
Unit type
Compressor type
Comfort (heating)
Eco (heating)
Storage comfort
Storage eco
Reheat
Field settings table
Installer setting at variance with
default value
Comfort (heating)
Eco (heating)
Comfort (heating)
Eco (heating)
(*5) *04/08*_
(*6) *16*
4P401673-1A - 2017.04