Breadcrumb Field code Setting name Range, step
Default valu
e
Date Value
Field settings table
Installer setting at variance with
default value
A.8 [6-08] R/W
2~20°C, step: 1°C
10°C
A.8 [6-09]
0
A.8 [6-0A] R/W 30~[6-0E]°C, step: 1°C
60°C
A.8 [6-0B] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
A.8 [6-0C] R/W 30~min(50, [6-0E])°C, step: 1°C
45°C
A.8 [6-0D] R/W 0: Reheat only
1: Reheat + sched.
2: Scheduled onl
y
A.8 [6-0E] R/W 40~60°C, step: 1°C
60°C
A.8 [7-00] R/W
0
A.8 [7-01] R/W
2
A.8 [7-02] R/W 0: 1 LWT zone
1: 2 LWT zones
A.8 [7-03]
2,5
A.8 [7-04]
0
A.8 [7-05] R/W
0: Very high
1: High
2: Medium
3: Low
4: Ver
y
low
A.8 [8-00]
1 min
A.8 [8-01] R/W 5~95 min, step: 5 min
30 min
A.8 [8-02] R/W 0~10 hour, step: 0,5 hour
0,5 hour
A.8 [8-03] R/W
50
A.8 [8-04] R/W 0~95 min, step: 5 min
95 min
A.8 [8-05] R/W
0: No
1: Yes
A.8 [8-06] R/W 0~10°C, step: 1°C
3°C
A.8 [8-07] R/W
18
A.8 [8-08] R/W
20
A.8 [8-09] R/W [9-01]~[9-00], step: 1°C
35°C
A.8 [8-0A] R/W [9-01]~[9-00], step: 1°C
33°C
A.8 [8-0B]
13
A.8 [8-0C]
10
A.8 [8-0D]
16
A.8 [9-00] R/W 37~55, step: 1°C
55°C
A.8 [9-01] R/W 15~37°C, step: 1°C
25°C
A.8 [9-02] R/W
22
A.8 [9-03] R/W
5
A.8 [9-04] R/W 1~4°C, step: 1°C
1°C
A.8 [9-05] R/W 15~37°C, step: 1°C
25°C
A.8 [9-06] R/W 37~55, step: 1°C
55°C
A.8 [9-07] R/W
5
A.8 [9-08] R/W
22
A.8 [9-09] R/W 3~10°C, step: 1°C
5°C
A.8 [9-0A] R/W
5
A.8 [9-0B] R/W 0: Quick
1: Slo
w
A.8 [9-0C] R/W 1~6°C, step: 0,5°C
1 °C
A.8 [9-0D] R/W 0~8, step:1
0 : 100%
1~4 : 80~50%
5~8 : 80~50%
6
A.8 [9-0E]
6
A.8 [A-00]
0
A.8 [A-01]
0 (*5)
3
(
*6
)
A.8 [A-02]
0 (*5)
1
(
*6
)
A.8 [A-03]
0
A.8 [A-04]
0
A.8 [B-00]
0
A.8 [B-01]
0
A.8 [B-02]
0
A.8 [B-03]
0
A.8 [B-04]
0
A.8 [C-00] R/O 0~1
1: Heat
p
um
p
p
riorit
y
A.8 [C-01]
0
A.8 [C-02] R/W
0~3
0: No
1: Bivalent
A.8 [C-03] R/W -25~25°C, step: 1°C
0°C
A.8 [C-04] R/W 2~10°C, step: 1°C
3°C
A.8 [C-05] R/W 1: Thermo ON/OFF
2: C/H re
q
ues
t
A.8 [C-06] R/W 0: -
1: Thermo ON/OFF
2: C/H re
q
ues
t
A.8 [C-07] R/W 0: LWT control
1: Ext RT control
2: RT control
Is an external backup heat source connected?
Bivalent activation temperature.
Bivalent hysteresis temperature.
What is the thermo request contact type for the main zone?
What is the thermo request contact type for the add. zone?
What is the unit control method in space operation?
--
--
--
--
Domestic heating water priority.
--
--
--
--
--
--
--
What is the desired delta T in heating?
--
What emitter type is connected to the main LWT zone?
Room temperature hysteresis.
Pump speed limitation
--
--
Leaving water temperature overshoot temperature.
What is the mimimum desired LWT for add. zone in heating?
What is the maximum desired LWT for add. zone in heating?
--
--
--
--
--
What is the maximum desired LWT for main zone in heating?
What is the mimimum desired LWT for main zone in heating?
--
Allow modulation of the LWT to control the room temp?
Leaving water temperature maximum modulation.
--
--
What is the desired comfort main LWT in heating?
What is the desired eco main LWT in heating?
Boiler efficiency
--
Maximum running time for domestic hot water operation.
Anti-recycling time.
--
Additional running time for the maximum running time.
What is the maximum temperature setpoint?
--
--
How many leaving water temperature zones are there?
--
--
What is the hysteresis to be used in reheat mode?
--
What is the desired comfort storage temperature?
What is the desired eco storage temperature?
What is the desired reheat temperature?
What is the desired DHW production type?
(*5) *04/08*_
(*6) *16*