ED12-321A Outdoor Units
Installation Manual 187
4
Selecting a location for installation of the indoor units
Outdoor Unit Installation Guidelines
Level
difference:
7.5m max.
(Heat pump
unit only)
Level
difference:
15m max.
Indoor Unit
Outdoor Unit
Level
difference:
15m max.
Outdoor Unit
Indoor Unit
Level
difference:
7.5m max.
(Heat pump
unit only)
More than 100 More than 350
Side view
1200
or less
More than 50 More than 50
More than 350
Top view
More
than 100
Top view
More than 100
More than 350
More than 50
The maximum allowable length of refrigerant piping, and the maximum allowable height difference between the
outdoor and indoor units, are listed below. (The shorter the refrigerant piping, the better the performance. Connect so
that the piping is as short as possible. Shortest allowable length per room is 3 m.)
If the outdoor unit is positioned higher than the indoor
units.
If the outdoor unit is positioned otherwise.
(If lower than one or more indoor units)
Outdoor unit capacity class
Piping to each indoor unit
Total length of piping between all units
4MXD80, 4MKD90
25m max.
70m max.
Where a wall or other obstacle is in the path of outdoor unit’s intake or exhaust airflow, follow the installation guidelines
below.
For any of the below installation patterns, the wall height on the exhaust side should be 1200 mm or less.
Wall facing one side Walls facing two sides
Walls facing three sides
Unit: mm