Daikin FHYB125FVAL [14/15] Specifications
![Daikin FHYB45FV1 [14/15] Specifications](/views2/1764483/page14/bge.png)
11 English
(These specifications are in compliance with SASO386.)
11.SPECIFICATIONS
INDOOR UNIT FHYB71FVAL FHYB100FVAL FHYB125FVAL
OUTDOOR UNIT RY71FUVAL RY100FUVAL RY125FUTAL
RATED VOLTAGE V 220 220 220
RATED FREQUENCY Hz 60 60 60
COOLING POWER INPUT RATING kW 4.3 5.9 6.7
CURRENT INPUT RATING A 20.3 27.4 18.0
CAPACITY kW 6.7 9.0 12.5
kcal/h 5800 7700 10800
HEATING POWER INPUT RATING kW 3.8 5.0 5.6
CURRENT INPUT RATING A 18.1 23.3 15.0
CAPACITY kW 8.5 11.8 15.0
kcal/h 7300 10100 12900
WEIGHT OF INDOOR UNIT kg 41 51 52
WEIGHT OF OUTDOOR UNIT kg 91 120 115
REFRIGERANT R22 R22 R22
MASS OF REFRIGERANT CHARGE kg 2.3 2.6 3.1
COUNTRY OF ORIGIN
indoor
JAPAN JAPAN JAPAN
out-
door
THAILAND THAILAND THAILAND
MANUFACTURER’S NAME
indoor
DAIKIN
INDUSTRIES
LTD.
DAIKIN
INDUSTRIES
LTD.
DAIKIN
INDUSTRIES
LTD.
out-
door
DAIKIN
INDUSTRIES
(THAILAND)
LTD.
DAIKIN
INDUSTRIES
(THAILAND)
LTD.
DAIKIN
INDUSTRIES
(THAILAND)
LTD.
01_EN_3P170549-1.fm Page 11 Friday, December 9, 2005 11:31 AM
Содержание
- Operation manual 1
- Split system air conditioner 1
- Contents 4
- Indoor unit 4
- Names and functions of parts 4
- Outdoor unit 4
- Precautions for group control system or two remote controller control system 4
- Safety considerations 4
- Unit with remote controller 4
- What to do before opera tion 4
- What to do before operation 4
- Cooling 6
- D b dry bulb temperature wb wet bulb temperature 6
- Do not place a burner or heater at a place directly exposed to the wind from the air con ditioner incomplete combustion of the burner or heater may result do not allow a child to mount on the outdoor unit or avoid placing any object on it falling or tumbling may result in injury never expose little children plants or ani mals directly to the air flow adverse influence to little children animals and plants may result do not wash the air conditioner with water an electric shock or fire may result do not install the air conditioner at any place where flammable gas may leak out if the gas leaks out and stays around the air con ditioner a fire may break out execute complete drain piping for perfect drainage incomplete piping may result in a water leakage the appliance is not intended for use by young children or infirm persons without supervision young children should be supervised to ensure that they do not play with the appli ance consult with installation contractor for cleaning the insi 6
- English 6
- Heat pump type 6
- Heating 6
- If the temperature or the humidity is beyond the fol lowing conditions safety devices may work and the air conditioner may not operate or sometimes water may drop from the indoor unit 6
- Installation site 6
- Is the air conditioner installed at a well ventilated place where there are no obstacles around 6
- Operation range 6
- Regarding places for installation 6
- The setting temperature range of the remote con troller is 16 c to 32 c 6
- And display on the remote controller 7
- Name and function of each switc 7
- Name and function of each switch and display on the remote controller 7
- Pay attention to running noises too 7
- Regarding drainage of drain piping 7
- Regarding wiring 7
- Cooling heating automatic fan and program dry operation 8
- Explanation of heating operation 8
- On off 8
- Operation mode selec tor 8
- Operation procedure 8
- Press on off button 8
- Press operation mode selector but ton several times and select the opera tion mode of your choice as follows 8
- Regarding outside air temperature and heat ing capacity 8
- Use this button for setting tempera ture 8
- Adjustment 9
- Fan speed control 9
- Optimum operation 9
- Press fan speed control button 9
- Press temperature setting button and program the setting temperature 9
- Press the programming time button and set the time for stopping or starting the sys tem 9
- Press the timer mode start stop button several times and select the mode on the display 9
- Press the timer on off button 9
- Program timer operation 9
- Programming time 9
- Temperature setting 9
- Timer mode start stop 9
- Timer on off 9
- How to clean the air filter 10
- Important 10
- Maintenance for service personnel 10
- How to clean air outlet suction grille and outside panels 11
- Not malfunction of the air conditioner 11
- Start up after a long stop 11
- What to do when stopping the sys tem for a long period 11
- Inspection display malfunction code 12
- Operation lamp 12
- Trouble shooting 12
- Specifications 14
- P170549 1 em95a019 15
Похожие устройства
- Daikin FHYB125FVAL Инструкция по эксплуатации
- Daikin FHYB125FVAL Сервис мануал
- Candy CCDS 5144WH Инструкция по эксплуатации EN
- Candy CCDS 6172W Инструкция по эксплуатации
- Candy CCDS 6172W Инструкция по эксплуатации EN
- Candy CCDS 6172WH Инструкция по эксплуатации
- Candy CCDS 6172WH Инструкция по эксплуатации EN
- Candy CCDS 6172WN Инструкция по эксплуатации
- Candy CCDS 6172WN Инструкция по эксплуатации EN
- Candy CCDS 6172X Инструкция по эксплуатации
- Candy CCDS 6172X Инструкция по эксплуатации EN
- Candy CCDS 6172XN Инструкция по эксплуатации
- Candy CCDS 6172XN Инструкция по эксплуатации EN
- Candy CCFET 6182WH Инструкция по эксплуатации
- Candy CCFET 6182WH Инструкция по эксплуатации EN
- Daikin FAY71LVE Руководство по эксплуатации
- Daikin FAY71LVE Инструкция по монтажу
- Daikin FAY71LVE Инструкция по эксплуатации
- Daikin FAYP71LV1 Руководство по эксплуатации
- Daikin FAYP71LV1 Инструкция по монтажу