Daikin FTXB35B1V1 [9/80] Preparation before operation

Daikin FTXB35B1V1 [9/80] Preparation before operation
8
Preparation before Operation
Turn the breaker on
After the power is turned on, the ap of the indoor unit opens and closes once to set the
reference position.
NOTE
Tips for saving energy
Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate
level helps save energy.
Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors
increases the cooling (heating) effect.
Recommended temperature setting
For cooling: 26-28°C
For heating: 20-24°C
Clogged air lters cause inef cient operation and waste energy. Clean them once in about
every 2 weeks.
Please note
The air conditioner always consumes 15-35W of electricity even while it is not operating.
If you are not going to use the air conditioner for a long period, for example in spring or
autumn, turn the breaker off.
Use the air conditioner in the following conditions.
Mode Operating conditions If operation is continued out of this range
COOL Outdoor temperature: 10-46°C
Indoor temperature: 18-32°C
Indoor humidity: 80% max.
A safety device may work to stop the operation.
Condensation may occur on the indoor unit and drip.
HEAT Outdoor temperature: –15-24°C
Indoor temperature: 10-30°C
A safety device may work to stop the operation.
DRY Outdoor temperature: 10-46°C
Indoor temperature: 18-32°C
Indoor humidity: 80% max.
A safety device may work to stop the operation.
Condensation may occur on the indoor unit and drip.
Operation outside this humidity or temperature range may cause a safety device to disable
the system.