Daikin FTXS35DVMW9 [97/205] Troubleshooting

Daikin FTXS20DVMW9 [97/205] Troubleshooting
SiEBE04-507 Troubleshooting
Service Diagnosis 87
4. Troubleshooting
4.1 Error Codes and Description
H: Displayed only when system-down occurs.
Code Indication Description
Reference
Page
System
00
Normal
U0H
Insufficient gas
117
U2
Over-voltage detection
119
U4
Signal transmission error (between indoor and outdoor unit)
94
UA
Unspecified voltage (between indoor and outdoor unit)
95
Indoor
Unit
A1
Indoor unit PCB abnormality
88
A5
Freeze-up protection control or high pressure control
89
A6
Fan motor or related abnormality
91
C4
Heat exchanger temperature thermistor abnormality
93
C9
Room temperature thermistor abnormality
93
Outdoor
Unit
E1
Outdoor unit PCB abnormality
96
E5H
OL activation (compressor overload)
97
E6H
Compressor lock
98
E7
DC fan lock
99
E8
Input over current detection
100
EA
Four way valve abnormality
101
F3
Discharge pipe temperature control
103
F6
High pressure control in cooling
104
H0
Compressor system sensor abnormality
106
H6
Position sensor abnormality
107
H8
DC voltage/current sensor abnormality
108
H9
Outdoor air thermistor or related abnormality
109
J3
Discharge pipe temperature thermistor or related abnormality
109
J6
Heat exchanger temperature thermistor or related abnormality
109
L3
Electrical box temperature rise
111
L4
Radiation fin temperature rise
113
L5
Output over current detection
115
P4
Heat radiation fin thermistor or related abnormality
109

Содержание