1 ■English
Safety Precautions
• Read these Safety Precautions carefully to ensure correct installation.
• This manual classifies the precautions into WARNING and CAUTION.
Be sure to follow all the precautions below: they are all important for ensuring safety.
WARNING
...............Failure to follow any of WARNING is likely to result in such grave consequences as death or serious injury.
CAUTION...............Failure to follow any of CAUTION may result in grave consequences in some cases.
• The following safety symbols are used throughout this manual:
• After completing installation, test the unit to check for installation errors. Give the user adequate instructions concerning the use
and cleaning of the unit according to the Operation Manual.
Be sure to observe this instruction. Be sure to establish an earth connection. Never attempt.
WARNING
• Installation should be left to the dealer or another professional.
Improper installation may cause water leakage, electrical shock, or fire.
• Install the air conditioner according to the instructions given in this manual.
Incomplete installation may cause water leakage, electrical shock, or fire.
• Be sure to use the supplied or specified installation parts.
Use of other parts may cause the unit to come to lose, water leakage, electrical shock, or fire.
• Install the air conditioner on a solid base that can support the weight of the unit.
An inadequate base or incomplete installation may cause injury in the event the unit falls off the base.
• Electrical work should be carried out in accordance with the installation manual and the national electrical wiring
rules or code of practice.
Insufficient capacity or incomplete electrical work may cause electrical shock or fire.
• Be sure to use a dedicated power circuit. Never use a power supply shared by another appliance.
• For wiring, use a cable length enough to cover the entire distance with no connection.
Do not use an extension cord. Do not put other loads on the power supply, use a dedicated power circuit.
(Failure to do so may cause abnormal heat, electric shock or fire.)
• Use the specified types of wires for electrical connections between the indoor and outdoor units.
Firmly clamp the interconnecting wires so their terminals receive no external stresses. Incomplete connections or clamping may cause terminal overheating or fire.
• After connecting interconnecting and supply wiring be sure to shape the cables so that they do not put undue force
on the electrical covers or panels.
Install covers over the wires. Incomplete cover installation may cause terminal overheating, electrical shock, or fire.
• If any refrigerant has leaked out during the installation work, ventilate the room.
(The refrigerant produces a toxic gas if exposed to flames.)
• After all installation is complete, check to make sure that no refrigerant is leaking out.
(The refrigerant produces a toxic gas if exposed to flames.)
• When installing or relocating the system, be sure to keep the refrigerant circuit free from substances other than the
specified refrigerant (R410A), such as air.
(Any presence of air or other foreign substance in the refrigerant circuit causes an abnormal pressure rise or rupture, resulting in injury.)
• During pump-down, stop the compressor before removing the refrigerant piping.
If the compressor is still running and the stop valve is open during pump-down, air will be sucked in when the refrigerant piping is removed,
causing abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• During installation, attach the refrigerant piping securely before running the compressor.
If the compressor is not attached and the stop valve is open during pump-down, air will be sucked in when the compressor is run, causing
abnormal pressure in the freezer cycle which will lead to breakage and even injury.
• Be sure to establish an earth. Do not earth the unit to a utility pipe, arrester, or telephone earth.
Incomplete earth may cause electrical shock, or fire. A high surge current from lightning or other sources may cause damage to the air conditioner.
• Be sure to install an earth leakage breaker.
Failure to install an earth leakage breaker may result in electric shocks, or fire.
CAUTION
• Do not install the air conditioner in a place where there is danger of exposure to inflammable gas leakage.
If the gas leaks and builds up around the unit, it may catch fire.
• Establish drain piping according to the instructions of this manual.
Inadequate piping may cause flooding.
• Tighten the flare nut according to the specified method such as with a torque wrench.
If the flare nut is tightened too hard, the flare nut may crack after a long time and cause refrigerant leakage.
01_EN_3P207973-2B.fm Page 1 Wednesday, December 5, 2007 9:14 AM
Содержание
- Installation manual 1
- Models atx20gv1b atx25gv1b atx35gv1b 1
- R410a split series 1
- Daikin industries ltd 2
- Electromagnetic compatibility 2004 108 ec 2
- Low voltage 2006 95 ec 2
- Machinery safety 98 37 ec 2
- Noboru murata manager quality control department shiga 1st of dec 2007 2
- Sb64117 3b 2
- Umeda center bldg 2 4 12 nakazaki nishi kita ku osaka 530 8323 japan 2
- Caution 3
- English 3
- Safety precautions 3
- Warning 3
- Accessories 4
- Choosing an installation site 4
- English 2 4
- Indoor unit 4
- Wireless remote controller 4
- Caution 5
- How to set the different addresses 5
- Installation tips 5
- Removing and installing front grille 5
- Removing and installing front panel 5
- When there is no work space because the unit is close to ceiling 5
- English 4 6
- Indoor unit installation drawings 6
- English 7
- Indoor unit installation 7
- Installing the mounting plate 7
- Boring a wall hole and installing wall embedded pipe 8
- English 6 8
- Installing indoor unit 8
- Right side right back or right bottom piping 8
- 2 left side left back or left bottom piping 9
- 3 wall embedded piping 9
- Attachment on the right side factory default 9
- Caulk this hole with putty or caulking material bind with vinyl tape 9
- Do not apply lubricating oil refrigeration oil when inserting application of causes deterioration and drain leakage of the plug 9
- Drain hose 9
- English 9
- How to replace the drain plug and drain hose 9
- Indoor unit fixing screw insulation fixing screw 9
- Indoor unit installation 9
- Insert a hexagon wrench 4mm 9
- Left bottom piping 9
- Left side piping left back piping 9
- Mounting plate 9
- No gap 9
- Remove pipe port cover here for left side piping 9
- Replacing onto the left side 9
- Right side left side 9
- The drain hose is on the back of the unit 9
- Wrap insulating tape around the bent portion of refrigerant pipe overlap at least half the width of the tape with each turn 9
- _en_3p207973 2b fm page 7 wednesday december 5 2007 9 14 am 9
- 1 remove the front grille 2 screws 5 2 remove the service lid 1 screw 5 3 remove the cover from the indoor unit electrical component box figure 1 5 4 remove the indoor unit electrical component box 10
- English 8 10
- Warning 10
- When connecting to a wired remote controller 10
- Wiring 10
- 5 8 install the indoor unit electrical component box in its original position 11
- 5 prepare the accessory separate product figure 2 11
- 6 install the cover of the electrical component box in its original position figure 3 5 7 install the accessory separate product figure 3 11
- 9 install the front grille in its original position 2 screws 5 10 install the service lid 1 screw 11
- Cut outs for the connection cords 11
- English 11
- Figure 2 preparing the accessory 11
- Figure 3 installing the accessory 11
- Indoor unit installation 11
- Drain piping 12
- Flaring the pipe end 12
- Refrigerant piping work 12
- Warning 12
- Caution 13
- Refrigerant piping 13
- Refrigerant piping work 13
- Test items 14
- Trial operation and testing 14
- P207973 2b m07b063a 15
Похожие устройства
- Daikin ATX35GV1B Инструкция по эксплуатации
- Daikin ATX35GV1B Сервис мануал
- Daikin ATXS20G2V1B Инструкция по монтажу
- Daikin ATXS20G2V1B Инструкция по эксплуатации
- Daikin ATXS20G2V1B Сервис мануал
- Daikin ATXS25G2V1B Инструкция по монтажу
- Daikin ATXS25G2V1B Инструкция по эксплуатации
- Daikin ATXS25G2V1B Сервис мануал
- Daikin ATXS35G2V1B Инструкция по монтажу
- Daikin ATXS35G2V1B Инструкция по эксплуатации
- Daikin ATXS35G2V1B Сервис мануал
- Daikin ATXS42G2V1B Инструкция по монтажу
- Daikin ATXS42G2V1B Инструкция по эксплуатации
- Daikin ATXS42G2V1B Сервис мануал
- Daikin ATXS50G2V1B Инструкция по монтажу
- Daikin ATXS50G2V1B Инструкция по эксплуатации
- Daikin ATXS50G2V1B Сервис мануал
- Daikin ATX20JV1B Инструкция по эксплуатации
- Daikin ATX20JV1B Технические данные
- Daikin ATX20JV1B Сервис мануал