Daikin FTXS50FVLT [104/244] Troubleshooting

Daikin FTKS71FVM [104/244] Troubleshooting
Si04-703A Troubleshooting
Service Diagnosis 93
4. Troubleshooting
4.1 Error Codes and Description
: Displayed only when system-down occurs.
Code Indication Description
Reference
Page
System
00
Normal
U0
Insufficient gas
126
U2
Low-voltage detection or over-voltage detection
128
U4
Signal transmission error (between indoor and outdoor units)
100
Indoor
Unit
A1
Indoor unit PCB abnormality
94
A5
Freeze-up protection control or high pressure control
95
A6
Fan motor or related abnormality
97
C4
Heat exchanger thermistor abnormality
99
C9
Room temperature thermistor abnormality
99
Outdoor
Unit
E1
Outdoor unit PCB abnormality
102
E5
OL activation (compressor overload)
103
E6
Compressor lock
104
E7
DC fan lock
105
E8
Input over current detection
106
EA
Four Way Valve Abnormality
108
F3
Discharge pipe temperature control
110
F6
High Pressure Control in Cooling
111
H0
Sensor abnormality
113
H6
Position sensor abnormality
115
H8
CT or related abnormality
116
H9
Outdoor air thermistor or related abnormality
118
J3
Discharge pipe thermistor or related abnormality
118
J6
Heat exchanger thermistor or related abnormality
118
L3
Electrical box temperature rise
120
L4
Radiation fin temperature rise
122
L5
Output over current detection
124
P4
Radiation fin thermistor or related abnormality
118
U7
Signal transmission error
129